辐照条件下60Co和137Cs伽玛射线束的标准化。

T P Loftus, J T Weaver
{"title":"辐照条件下60Co和137Cs伽玛射线束的标准化。","authors":"T P Loftus,&nbsp;J T Weaver","doi":"10.6028/jres.078A.030","DOIUrl":null,"url":null,"abstract":"<p><p>At the National Bureau of Standards (NBS), the exposure-rate standards for <sup>60</sup>Co and <sup>137</sup>Cs gamma rays were based for a number of years on a weighted average of measurements using a cylindrical ionization chamber and a group of small spherical chambers. Complex setup conditions for the cylindrical chamber, differences between the cylindrical and spherical chamber data, and recognition that the institution of this weighted average exposure-rate standard increased the difference between free-air-chamber and cavily-chamber measurements, led to the development of new spherical chambers. All correction factors for exposure-rate measurements were investigated and updated. Excellent agreement was achieved between independent exposure-rate measurements for six spherical chambers and, as of May 1, 1972, the exposure standards were reduced 0.7 percent for <sup>60</sup>Co and 0.6 percent for <sup>137</sup>Cs gamma rays. Recalculation of correction factors since that time indicates that the standard <sup>137</sup>Cs should be further reduced by 0.2 percent, and this adjustment was made on July 1, 1974. The uncertainties associated with each of the quantities entering into the determination of exposure rate were tabulated and the overall uncertainty of the exposure rates used for instrument calibrations at NBS was found to be about 0.7 percent for addition in quadrature.</p>","PeriodicalId":17018,"journal":{"name":"Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry","volume":"78A 4","pages":"465-476"},"PeriodicalIF":0.0000,"publicationDate":"1974-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6742815/pdf/jres-78A-465.pdf","citationCount":"60","resultStr":"{\"title\":\"Standardization of <sup>60</sup>Co and <sup>137</sup>Cs Gamma-Ray Beams in Terms of Exposure.\",\"authors\":\"T P Loftus,&nbsp;J T Weaver\",\"doi\":\"10.6028/jres.078A.030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>At the National Bureau of Standards (NBS), the exposure-rate standards for <sup>60</sup>Co and <sup>137</sup>Cs gamma rays were based for a number of years on a weighted average of measurements using a cylindrical ionization chamber and a group of small spherical chambers. Complex setup conditions for the cylindrical chamber, differences between the cylindrical and spherical chamber data, and recognition that the institution of this weighted average exposure-rate standard increased the difference between free-air-chamber and cavily-chamber measurements, led to the development of new spherical chambers. All correction factors for exposure-rate measurements were investigated and updated. Excellent agreement was achieved between independent exposure-rate measurements for six spherical chambers and, as of May 1, 1972, the exposure standards were reduced 0.7 percent for <sup>60</sup>Co and 0.6 percent for <sup>137</sup>Cs gamma rays. Recalculation of correction factors since that time indicates that the standard <sup>137</sup>Cs should be further reduced by 0.2 percent, and this adjustment was made on July 1, 1974. The uncertainties associated with each of the quantities entering into the determination of exposure rate were tabulated and the overall uncertainty of the exposure rates used for instrument calibrations at NBS was found to be about 0.7 percent for addition in quadrature.</p>\",\"PeriodicalId\":17018,\"journal\":{\"name\":\"Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry\",\"volume\":\"78A 4\",\"pages\":\"465-476\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1974-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6742815/pdf/jres-78A-465.pdf\",\"citationCount\":\"60\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.6028/jres.078A.030\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6028/jres.078A.030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 60

摘要

在国家标准局(NBS),60Co和137Cs伽马射线的暴露率标准是基于多年来使用圆柱形电离室和一组小球形电离室进行的加权平均测量。圆柱形腔室的复杂设置条件,圆柱形和球形腔室数据之间的差异,以及这种加权平均暴露率标准的制定增加了自由空气腔室和空腔腔室测量之间的差异的认识,导致了新球形腔室的开发。对暴露率测量的所有校正因子进行了调查和更新。在六个球形室的独立暴露率测量之间取得了良好的一致性,截至1972年5月1日,60Co和137Cs伽马射线的暴露标准分别降低了0.7%和0.6%。从那时起重新计算校正系数表明,标准137Cs应进一步降低0.2%,这一调整是在1974年7月1日做出的。表中列出了与进入暴露率测定的每个量相关的不确定度,发现用于NBS仪器校准的暴露率的总不确定度约为0.7%(正交加法)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Standardization of 60Co and 137Cs Gamma-Ray Beams in Terms of Exposure.

At the National Bureau of Standards (NBS), the exposure-rate standards for 60Co and 137Cs gamma rays were based for a number of years on a weighted average of measurements using a cylindrical ionization chamber and a group of small spherical chambers. Complex setup conditions for the cylindrical chamber, differences between the cylindrical and spherical chamber data, and recognition that the institution of this weighted average exposure-rate standard increased the difference between free-air-chamber and cavily-chamber measurements, led to the development of new spherical chambers. All correction factors for exposure-rate measurements were investigated and updated. Excellent agreement was achieved between independent exposure-rate measurements for six spherical chambers and, as of May 1, 1972, the exposure standards were reduced 0.7 percent for 60Co and 0.6 percent for 137Cs gamma rays. Recalculation of correction factors since that time indicates that the standard 137Cs should be further reduced by 0.2 percent, and this adjustment was made on July 1, 1974. The uncertainties associated with each of the quantities entering into the determination of exposure rate were tabulated and the overall uncertainty of the exposure rates used for instrument calibrations at NBS was found to be about 0.7 percent for addition in quadrature.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信