【内锚植入治疗内漏】。

Sandra Figueiredo Braga, João Correia Simões, Celso Carrilho, Joana Ferreira, Amílca Mesquita
{"title":"【内锚植入治疗内漏】。","authors":"Sandra Figueiredo Braga,&nbsp;João Correia Simões,&nbsp;Celso Carrilho,&nbsp;Joana Ferreira,&nbsp;Amílca Mesquita","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The authors describe a clinical case of correction of a type 1A endoleak after EVAR using endo-anchors. An 85-year old female was referred due to an abdominal aortic aneurysm. The patient´s previous medical history included hypertension, dyslipidemia, renal insufficiency and multiple abdominal surgeries (appendicectomy, classic cholecystectomy and hysterectomy). The aneurysm had 7.5 cm diameter with an angulated short 14 mm neck extension. She underwent an uneventful EVAR with placement of a Medtronic® Endurant II stentgraft. One month after the procedure the abdominal computed tomographic angiography (CTA) revealed a type 1A endoleak. Correction of endoleak consisted of left renal artery stenting (the lowest one), placement of a proximal aortic cuff and 9 endo-anchors (APTUS® System) with satisfactory end result. The control CTA after re-intervention showed patency of the renal arteries and the stentgraft, aneurysm exclusion and absence of endoleaks.</p>","PeriodicalId":87136,"journal":{"name":"Revista portuguesa de cirurgia cardio-toracica e vascular : orgao oficial da Sociedade Portuguesa de Cirurgia Cardio-Toracica e Vascular","volume":"26 4","pages":"279-283"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Endoanchor implantation for treatment of endoleak].\",\"authors\":\"Sandra Figueiredo Braga,&nbsp;João Correia Simões,&nbsp;Celso Carrilho,&nbsp;Joana Ferreira,&nbsp;Amílca Mesquita\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The authors describe a clinical case of correction of a type 1A endoleak after EVAR using endo-anchors. An 85-year old female was referred due to an abdominal aortic aneurysm. The patient´s previous medical history included hypertension, dyslipidemia, renal insufficiency and multiple abdominal surgeries (appendicectomy, classic cholecystectomy and hysterectomy). The aneurysm had 7.5 cm diameter with an angulated short 14 mm neck extension. She underwent an uneventful EVAR with placement of a Medtronic® Endurant II stentgraft. One month after the procedure the abdominal computed tomographic angiography (CTA) revealed a type 1A endoleak. Correction of endoleak consisted of left renal artery stenting (the lowest one), placement of a proximal aortic cuff and 9 endo-anchors (APTUS® System) with satisfactory end result. The control CTA after re-intervention showed patency of the renal arteries and the stentgraft, aneurysm exclusion and absence of endoleaks.</p>\",\"PeriodicalId\":87136,\"journal\":{\"name\":\"Revista portuguesa de cirurgia cardio-toracica e vascular : orgao oficial da Sociedade Portuguesa de Cirurgia Cardio-Toracica e Vascular\",\"volume\":\"26 4\",\"pages\":\"279-283\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista portuguesa de cirurgia cardio-toracica e vascular : orgao oficial da Sociedade Portuguesa de Cirurgia Cardio-Toracica e Vascular\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista portuguesa de cirurgia cardio-toracica e vascular : orgao oficial da Sociedade Portuguesa de Cirurgia Cardio-Toracica e Vascular","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

作者描述了一例使用内锚修复EVAR后1A型内漏的临床病例。一位85岁的女性因腹主动脉瘤被转诊。患者既往病史包括高血压、血脂异常、肾功能不全和多次腹部手术(阑尾切除术、经典胆囊切除术和子宫切除术)。动脉瘤直径7.5 cm,颈延伸呈角状短14 mm。她进行了一次平稳的EVAR手术,植入了Medtronic®endurance II支架。术后一个月腹部计算机断层血管造影(CTA)显示1A型内漏。内漏矫正包括左肾动脉支架置入术(最低位),近端主动脉袖带放置和9个内锚(APTUS®系统),最终结果令人满意。再干预后对照CTA显示肾动脉和支架通畅,动脉瘤排除,无内漏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Endoanchor implantation for treatment of endoleak].

The authors describe a clinical case of correction of a type 1A endoleak after EVAR using endo-anchors. An 85-year old female was referred due to an abdominal aortic aneurysm. The patient´s previous medical history included hypertension, dyslipidemia, renal insufficiency and multiple abdominal surgeries (appendicectomy, classic cholecystectomy and hysterectomy). The aneurysm had 7.5 cm diameter with an angulated short 14 mm neck extension. She underwent an uneventful EVAR with placement of a Medtronic® Endurant II stentgraft. One month after the procedure the abdominal computed tomographic angiography (CTA) revealed a type 1A endoleak. Correction of endoleak consisted of left renal artery stenting (the lowest one), placement of a proximal aortic cuff and 9 endo-anchors (APTUS® System) with satisfactory end result. The control CTA after re-intervention showed patency of the renal arteries and the stentgraft, aneurysm exclusion and absence of endoleaks.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信