{"title":"温控多频单极射频装置单次治疗改善腹部及侧腹局部肥胖的超声评价","authors":"Amy Taub, James Bartholomeusz","doi":"10.36849/JDD.2020.4568","DOIUrl":null,"url":null,"abstract":"<p><p>BACKGROUND AND OBJECTIVES: Energy modalities used for fat reduction include cryotherapy, focused and unfocused ultrasound, radiofrequency, and laser. Two devices have been proven to reduce fat layer thickness using ultrasound as measurement after a single treatment. We hypothesized that a novel, high frequency monopolar radiofrequency device could increase the fat temperature enough to reduce its thickness as measured by ultrasound, without excessively increasing the temperature of the skin, leading to a safe, tolerable, and clinically relevant reduction of fat.\n\nSTUDY DESIGN/MATERIALS AND METHODS: A high frequency monopolar radiofrequency platform was used to treat twelve patients on the abdomen or flanks (truSculpt® 3D, Cutera, Brisbane, CA). Each patient received one treatment session, consisting of 15-minute increments for four areas (60 minutes total). Each area (approximately 144 cm2) was treated with a gliding handpiece technique to a skin temperature of 44-45˚C, correlating to in vivo measurements of the subcutaneous layer of >45˚C. Patients were evaluated at eight- and twelve-weeks following treatment. Clinical efficacy was measured using 360˚ positioned clinical photography. Fat layer reduction was measured with ultrasound. Safety was assessed by the treating physician; patient comfort was assessed during treatment via a 10-point pain scale.\n\nRESULTS: All patients responded to treatment. Ultrasound measurements indicated mean fat layer reduction of 4.6 mm, which correlated with a 24% reduction in fat layer thickness at 12 weeks. A significant improvement was noted between the 8-week and the 12-week follow up. A high level of inter-patient consistency was achieved with most patients (10/12= 83%) having an average fat thickness reduction of >20%. No adverse events were observed, and pain scores during the treatment session ranged from 2 to 4 out of 10.\n\nCONCLUSION: High frequency monopolar radiofrequency device produced consistent and statistically significant fat thickness reduction from a single 60-minute treatment session, with minimal discomfort and no demonstrated side effects. Results are comparable to other hypo- and hyper-thermic fat treatment technologies.\n\nKEY WORDS: fat reduction, radiofrequency, monopolar RF, fat thickness reduction, body sculpting\n\nJ Drugs Dermatol. 2020;19(1):28-34. doi:10.36849/JDD.2020.4568</p>","PeriodicalId":15566,"journal":{"name":"Journal of Drugs in Dermatology","volume":"19 1","pages":"28-34"},"PeriodicalIF":1.5000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Ultrasound Evaluation of a Single Treatment With a Temperature Controlled Multi-Frequency Monopolar Radio Frequency Device for the Improvement of Localized Adiposity on the Abdomen and Flanks\",\"authors\":\"Amy Taub, James Bartholomeusz\",\"doi\":\"10.36849/JDD.2020.4568\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>BACKGROUND AND OBJECTIVES: Energy modalities used for fat reduction include cryotherapy, focused and unfocused ultrasound, radiofrequency, and laser. Two devices have been proven to reduce fat layer thickness using ultrasound as measurement after a single treatment. We hypothesized that a novel, high frequency monopolar radiofrequency device could increase the fat temperature enough to reduce its thickness as measured by ultrasound, without excessively increasing the temperature of the skin, leading to a safe, tolerable, and clinically relevant reduction of fat.\\n\\nSTUDY DESIGN/MATERIALS AND METHODS: A high frequency monopolar radiofrequency platform was used to treat twelve patients on the abdomen or flanks (truSculpt® 3D, Cutera, Brisbane, CA). Each patient received one treatment session, consisting of 15-minute increments for four areas (60 minutes total). Each area (approximately 144 cm2) was treated with a gliding handpiece technique to a skin temperature of 44-45˚C, correlating to in vivo measurements of the subcutaneous layer of >45˚C. Patients were evaluated at eight- and twelve-weeks following treatment. Clinical efficacy was measured using 360˚ positioned clinical photography. Fat layer reduction was measured with ultrasound. Safety was assessed by the treating physician; patient comfort was assessed during treatment via a 10-point pain scale.\\n\\nRESULTS: All patients responded to treatment. Ultrasound measurements indicated mean fat layer reduction of 4.6 mm, which correlated with a 24% reduction in fat layer thickness at 12 weeks. A significant improvement was noted between the 8-week and the 12-week follow up. A high level of inter-patient consistency was achieved with most patients (10/12= 83%) having an average fat thickness reduction of >20%. No adverse events were observed, and pain scores during the treatment session ranged from 2 to 4 out of 10.\\n\\nCONCLUSION: High frequency monopolar radiofrequency device produced consistent and statistically significant fat thickness reduction from a single 60-minute treatment session, with minimal discomfort and no demonstrated side effects. Results are comparable to other hypo- and hyper-thermic fat treatment technologies.\\n\\nKEY WORDS: fat reduction, radiofrequency, monopolar RF, fat thickness reduction, body sculpting\\n\\nJ Drugs Dermatol. 2020;19(1):28-34. doi:10.36849/JDD.2020.4568</p>\",\"PeriodicalId\":15566,\"journal\":{\"name\":\"Journal of Drugs in Dermatology\",\"volume\":\"19 1\",\"pages\":\"28-34\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Drugs in Dermatology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.36849/JDD.2020.4568\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DERMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Drugs in Dermatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.36849/JDD.2020.4568","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DERMATOLOGY","Score":null,"Total":0}
Ultrasound Evaluation of a Single Treatment With a Temperature Controlled Multi-Frequency Monopolar Radio Frequency Device for the Improvement of Localized Adiposity on the Abdomen and Flanks
BACKGROUND AND OBJECTIVES: Energy modalities used for fat reduction include cryotherapy, focused and unfocused ultrasound, radiofrequency, and laser. Two devices have been proven to reduce fat layer thickness using ultrasound as measurement after a single treatment. We hypothesized that a novel, high frequency monopolar radiofrequency device could increase the fat temperature enough to reduce its thickness as measured by ultrasound, without excessively increasing the temperature of the skin, leading to a safe, tolerable, and clinically relevant reduction of fat.
STUDY DESIGN/MATERIALS AND METHODS: A high frequency monopolar radiofrequency platform was used to treat twelve patients on the abdomen or flanks (truSculpt® 3D, Cutera, Brisbane, CA). Each patient received one treatment session, consisting of 15-minute increments for four areas (60 minutes total). Each area (approximately 144 cm2) was treated with a gliding handpiece technique to a skin temperature of 44-45˚C, correlating to in vivo measurements of the subcutaneous layer of >45˚C. Patients were evaluated at eight- and twelve-weeks following treatment. Clinical efficacy was measured using 360˚ positioned clinical photography. Fat layer reduction was measured with ultrasound. Safety was assessed by the treating physician; patient comfort was assessed during treatment via a 10-point pain scale.
RESULTS: All patients responded to treatment. Ultrasound measurements indicated mean fat layer reduction of 4.6 mm, which correlated with a 24% reduction in fat layer thickness at 12 weeks. A significant improvement was noted between the 8-week and the 12-week follow up. A high level of inter-patient consistency was achieved with most patients (10/12= 83%) having an average fat thickness reduction of >20%. No adverse events were observed, and pain scores during the treatment session ranged from 2 to 4 out of 10.
CONCLUSION: High frequency monopolar radiofrequency device produced consistent and statistically significant fat thickness reduction from a single 60-minute treatment session, with minimal discomfort and no demonstrated side effects. Results are comparable to other hypo- and hyper-thermic fat treatment technologies.
KEY WORDS: fat reduction, radiofrequency, monopolar RF, fat thickness reduction, body sculpting
J Drugs Dermatol. 2020;19(1):28-34. doi:10.36849/JDD.2020.4568
期刊介绍:
The Journal of Drugs in Dermatology (JDD) is a peer-reviewed publication indexed with MEDLINE®/PubMed® that was founded by the renowned Dr. Perry Robins MD. Founded in 2002, it offers one of the fastest routes to disseminate dermatologic information and is considered the fastest growing publication in dermatology.