Daniel P Rothschild, James A Goldstein, Joseph Ciacci, Terry R Bowers
{"title":"超声加速溶栓(USAT)与标准导管定向溶栓(CDT)治疗肺栓塞:回顾性分析。","authors":"Daniel P Rothschild, James A Goldstein, Joseph Ciacci, Terry R Bowers","doi":"10.1177/1358863X19838350","DOIUrl":null,"url":null,"abstract":"<p><p>Ultrasound-accelerated thrombolysis (USAT) is advocated in pulmonary embolism (PE) based on the hypothesis that adjunctive ultrasound provides superior clinical efficacy compared to standard catheter-directed thrombolysis (CDT). This retrospective study was designed to compare outcomes between the two modalities. We analyzed patients with computed tomography-diagnosed PE at our institution treated with either USAT or standard CDT. Efficacy parameters assessed included invasive pulmonary artery systolic pressure (PASP; pre- and 24 hours post-treatment), non-invasive right-to-left ventricle (RV/LV) ratio (pre- and post-treatment), and general clinical outcomes (length-of-stay, significant bleeding, and mortality). We analyzed 98 cases (62 USAT and 36 CDT), in whom massive PE was diagnosed in 7%, intermediate/high risk in 81%, and intermediate/low risk in 12%. Overall, 92% had bilateral clot and 40% saddle embolus. At 24 hours, PASP decreased similarly in both groups (CDT Δ14.7 mmHg, USAT Δ10.8 mmHg; p = 0.14). Post-treatment, CDT showed similar improvement in the RV/LV ratio (CDT Δ0.58 vs USAT Δ0.45; p = 0.07), despite the baseline ratio being greater in the CDT group, indicating more severe RV strain (1.56 ± 0.36 vs 1.40 ± 0.29; p = 0.01). Intensive care unit and hospital length-of-stays were similar in both groups. A trend toward lesser significant bleeding rates in the CDT group (8.3% vs 12.9%, p = 0.74) as well as improved survival-to-discharge (97.2% vs 91.9%, p = 0.66) was observed. Compared to USAT, standard CDT achieves similar beneficial effects on hemodynamics, RV/LV ratios, and clinical outcomes. These observations suggest that salutary clinical results may be achieved without the need for very expensive devices.</p>","PeriodicalId":151049,"journal":{"name":"Vascular Medicine (London, England)","volume":" ","pages":"234-240"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1358863X19838350","citationCount":"38","resultStr":"{\"title\":\"Ultrasound-accelerated thrombolysis (USAT) versus standard catheter-directed thrombolysis (CDT) for treatment of pulmonary embolism: A retrospective analysis.\",\"authors\":\"Daniel P Rothschild, James A Goldstein, Joseph Ciacci, Terry R Bowers\",\"doi\":\"10.1177/1358863X19838350\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ultrasound-accelerated thrombolysis (USAT) is advocated in pulmonary embolism (PE) based on the hypothesis that adjunctive ultrasound provides superior clinical efficacy compared to standard catheter-directed thrombolysis (CDT). This retrospective study was designed to compare outcomes between the two modalities. We analyzed patients with computed tomography-diagnosed PE at our institution treated with either USAT or standard CDT. Efficacy parameters assessed included invasive pulmonary artery systolic pressure (PASP; pre- and 24 hours post-treatment), non-invasive right-to-left ventricle (RV/LV) ratio (pre- and post-treatment), and general clinical outcomes (length-of-stay, significant bleeding, and mortality). We analyzed 98 cases (62 USAT and 36 CDT), in whom massive PE was diagnosed in 7%, intermediate/high risk in 81%, and intermediate/low risk in 12%. Overall, 92% had bilateral clot and 40% saddle embolus. At 24 hours, PASP decreased similarly in both groups (CDT Δ14.7 mmHg, USAT Δ10.8 mmHg; p = 0.14). Post-treatment, CDT showed similar improvement in the RV/LV ratio (CDT Δ0.58 vs USAT Δ0.45; p = 0.07), despite the baseline ratio being greater in the CDT group, indicating more severe RV strain (1.56 ± 0.36 vs 1.40 ± 0.29; p = 0.01). Intensive care unit and hospital length-of-stays were similar in both groups. A trend toward lesser significant bleeding rates in the CDT group (8.3% vs 12.9%, p = 0.74) as well as improved survival-to-discharge (97.2% vs 91.9%, p = 0.66) was observed. Compared to USAT, standard CDT achieves similar beneficial effects on hemodynamics, RV/LV ratios, and clinical outcomes. These observations suggest that salutary clinical results may be achieved without the need for very expensive devices.</p>\",\"PeriodicalId\":151049,\"journal\":{\"name\":\"Vascular Medicine (London, England)\",\"volume\":\" \",\"pages\":\"234-240\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/1358863X19838350\",\"citationCount\":\"38\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vascular Medicine (London, England)\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/1358863X19838350\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2019/3/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular Medicine (London, England)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/1358863X19838350","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/3/27 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 38
摘要
超声加速溶栓(USAT)被提倡用于肺栓塞(PE),其假设是辅助超声比标准的导管导向溶栓(CDT)具有更好的临床疗效。本回顾性研究旨在比较两种治疗方式的疗效。我们分析了在我们机构接受USAT或标准CDT治疗的计算机断层扫描诊断的PE患者。评估的疗效参数包括有创肺动脉收缩压(PASP);治疗前和治疗后24小时)、非侵入性右-左心室(RV/LV)比(治疗前和治疗后)以及一般临床结果(住院时间、显著出血和死亡率)。我们分析了98例(62例USAT和36例CDT),其中7%诊断为大量PE, 81%为中/高风险,12%为中/低风险。总的来说,92%有双侧凝块,40%有鞍状栓子。24小时时,两组PASP下降相似(CDT Δ14.7 mmHg, USAT Δ10.8 mmHg;P = 0.14)。治疗后,CDT在RV/LV比值方面也有类似的改善(CDT Δ0.58 vs USAT Δ0.45;p = 0.07),尽管CDT组的基线比值更大,表明RV毒株更严重(1.56±0.36 vs 1.40±0.29;P = 0.01)。两组患者的重症监护病房和住院时间相似。观察到CDT组显著出血率较低的趋势(8.3% vs 12.9%, p = 0.74)以及生存率提高(97.2% vs 91.9%, p = 0.66)。与USAT相比,标准CDT在血流动力学、左室/左室比和临床结果方面取得了相似的有益效果。这些观察结果表明,不需要非常昂贵的设备就可以获得有益的临床结果。
Ultrasound-accelerated thrombolysis (USAT) versus standard catheter-directed thrombolysis (CDT) for treatment of pulmonary embolism: A retrospective analysis.
Ultrasound-accelerated thrombolysis (USAT) is advocated in pulmonary embolism (PE) based on the hypothesis that adjunctive ultrasound provides superior clinical efficacy compared to standard catheter-directed thrombolysis (CDT). This retrospective study was designed to compare outcomes between the two modalities. We analyzed patients with computed tomography-diagnosed PE at our institution treated with either USAT or standard CDT. Efficacy parameters assessed included invasive pulmonary artery systolic pressure (PASP; pre- and 24 hours post-treatment), non-invasive right-to-left ventricle (RV/LV) ratio (pre- and post-treatment), and general clinical outcomes (length-of-stay, significant bleeding, and mortality). We analyzed 98 cases (62 USAT and 36 CDT), in whom massive PE was diagnosed in 7%, intermediate/high risk in 81%, and intermediate/low risk in 12%. Overall, 92% had bilateral clot and 40% saddle embolus. At 24 hours, PASP decreased similarly in both groups (CDT Δ14.7 mmHg, USAT Δ10.8 mmHg; p = 0.14). Post-treatment, CDT showed similar improvement in the RV/LV ratio (CDT Δ0.58 vs USAT Δ0.45; p = 0.07), despite the baseline ratio being greater in the CDT group, indicating more severe RV strain (1.56 ± 0.36 vs 1.40 ± 0.29; p = 0.01). Intensive care unit and hospital length-of-stays were similar in both groups. A trend toward lesser significant bleeding rates in the CDT group (8.3% vs 12.9%, p = 0.74) as well as improved survival-to-discharge (97.2% vs 91.9%, p = 0.66) was observed. Compared to USAT, standard CDT achieves similar beneficial effects on hemodynamics, RV/LV ratios, and clinical outcomes. These observations suggest that salutary clinical results may be achieved without the need for very expensive devices.