在心脏手术中使用简单球囊法成功取出器械。

Q2 Medicine
Shivanand Patil, Natraj Setty, Rangaraj Ramalingam, Jayasheelan Mambally, Cholenahally Nanjappa Manjunath
{"title":"在心脏手术中使用简单球囊法成功取出器械。","authors":"Shivanand Patil,&nbsp;Natraj Setty,&nbsp;Rangaraj Ramalingam,&nbsp;Jayasheelan Mambally,&nbsp;Cholenahally Nanjappa Manjunath","doi":"10.1556/1646.10.2018.36","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Although rare, incidents of broken/dislodged fragment of various angioplasty hardwares, including catheters, guidewires, angioplasty balloons, and stents, are being increasingly reported in recent years. Since these broken fragments may cause life-threatening consequences for a patient, it is vital for an interventional cardiologist to be acquainted with different retrieval techniques. Here, we are reporting our observations of several incidents of device dislodgement/fracture during cardiac interventions and their retrieval using simple balloon method.</p><p><strong>Methods: </strong>We present a study of eight patients in whom we attempted to retrieve dislodged/fractured cath-lab hardwares during cardiac interventions, using simple balloon method. These cases include two cases of balloon, three cases of stent, and three cases of guidewire dislodgement/fracture.</p><p><strong>Results: </strong>Fractured/dislodged cath-lab hardwares were successfully retrieved using a simple balloon method in six out of eight cases (75%), without any need of other retrieval hardwares. We observed no major complications in any patient.</p><p><strong>Conclusions: </strong>The balloon-assisted retrieval method is a simple, safe, and cost-effective way to avoid complications of endothelial injury, myocardial infarction, emergency coronary artery bypass graft, and sudden cardiac death. This study, particularly the context of retrieval technique used in each case, will offer valuable information to fellow interventional cardiologists.</p>","PeriodicalId":45181,"journal":{"name":"Interventional Medicine and Applied Science","volume":"10 4","pages":"186-190"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1556/1646.10.2018.36","citationCount":"2","resultStr":"{\"title\":\"Successful device retrieval using simple balloon method during cardiac procedures.\",\"authors\":\"Shivanand Patil,&nbsp;Natraj Setty,&nbsp;Rangaraj Ramalingam,&nbsp;Jayasheelan Mambally,&nbsp;Cholenahally Nanjappa Manjunath\",\"doi\":\"10.1556/1646.10.2018.36\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Although rare, incidents of broken/dislodged fragment of various angioplasty hardwares, including catheters, guidewires, angioplasty balloons, and stents, are being increasingly reported in recent years. Since these broken fragments may cause life-threatening consequences for a patient, it is vital for an interventional cardiologist to be acquainted with different retrieval techniques. Here, we are reporting our observations of several incidents of device dislodgement/fracture during cardiac interventions and their retrieval using simple balloon method.</p><p><strong>Methods: </strong>We present a study of eight patients in whom we attempted to retrieve dislodged/fractured cath-lab hardwares during cardiac interventions, using simple balloon method. These cases include two cases of balloon, three cases of stent, and three cases of guidewire dislodgement/fracture.</p><p><strong>Results: </strong>Fractured/dislodged cath-lab hardwares were successfully retrieved using a simple balloon method in six out of eight cases (75%), without any need of other retrieval hardwares. We observed no major complications in any patient.</p><p><strong>Conclusions: </strong>The balloon-assisted retrieval method is a simple, safe, and cost-effective way to avoid complications of endothelial injury, myocardial infarction, emergency coronary artery bypass graft, and sudden cardiac death. This study, particularly the context of retrieval technique used in each case, will offer valuable information to fellow interventional cardiologists.</p>\",\"PeriodicalId\":45181,\"journal\":{\"name\":\"Interventional Medicine and Applied Science\",\"volume\":\"10 4\",\"pages\":\"186-190\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1556/1646.10.2018.36\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Medicine and Applied Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1556/1646.10.2018.36\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Medicine and Applied Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1556/1646.10.2018.36","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

摘要

目的:尽管罕见,但近年来,各种血管成形术硬件(包括导管、导丝、血管成形术球囊和支架)破碎/移位的事件越来越多。由于这些破碎的碎片可能会对患者造成危及生命的后果,因此对介入心脏病专家来说,熟悉不同的回收技术是至关重要的。在此,我们报告了我们观察到的几例心脏介入手术中器械脱位/骨折的事件,并使用简单的球囊法将其取出。方法:我们对8例患者进行了研究,在心脏介入治疗期间,我们试图使用简单的球囊法恢复脱位/断裂的导管室硬件。其中球囊2例,支架3例,导丝移位/骨折3例。结果:8例患者中有6例(75%)采用简单球囊法成功取出断裂/移位的导管室硬体,无需使用其他硬体。我们未观察到任何患者出现重大并发症。结论:球囊辅助取物术是一种简单、安全、经济的方法,可避免内皮损伤、心肌梗死、急诊冠状动脉搭桥术、心源性猝死等并发症。这项研究,特别是在每个病例中使用的检索技术的背景下,将为其他介入心脏病学家提供有价值的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Successful device retrieval using simple balloon method during cardiac procedures.

Successful device retrieval using simple balloon method during cardiac procedures.

Objectives: Although rare, incidents of broken/dislodged fragment of various angioplasty hardwares, including catheters, guidewires, angioplasty balloons, and stents, are being increasingly reported in recent years. Since these broken fragments may cause life-threatening consequences for a patient, it is vital for an interventional cardiologist to be acquainted with different retrieval techniques. Here, we are reporting our observations of several incidents of device dislodgement/fracture during cardiac interventions and their retrieval using simple balloon method.

Methods: We present a study of eight patients in whom we attempted to retrieve dislodged/fractured cath-lab hardwares during cardiac interventions, using simple balloon method. These cases include two cases of balloon, three cases of stent, and three cases of guidewire dislodgement/fracture.

Results: Fractured/dislodged cath-lab hardwares were successfully retrieved using a simple balloon method in six out of eight cases (75%), without any need of other retrieval hardwares. We observed no major complications in any patient.

Conclusions: The balloon-assisted retrieval method is a simple, safe, and cost-effective way to avoid complications of endothelial injury, myocardial infarction, emergency coronary artery bypass graft, and sudden cardiac death. This study, particularly the context of retrieval technique used in each case, will offer valuable information to fellow interventional cardiologists.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Interventional Medicine and Applied Science
Interventional Medicine and Applied Science MEDICINE, GENERAL & INTERNAL-
CiteScore
1.60
自引率
0.00%
发文量
0
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信