激光与旋转仪器的比较——一个案例研究。

Paul Gregory, James Lea, Christopher Walinski, Denise Terese-Koch, Timothy Hottel, Dan Fields, Christopher Rodriguez
{"title":"激光与旋转仪器的比较——一个案例研究。","authors":"Paul Gregory,&nbsp;James Lea,&nbsp;Christopher Walinski,&nbsp;Denise Terese-Koch,&nbsp;Timothy Hottel,&nbsp;Dan Fields,&nbsp;Christopher Rodriguez","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The use of an erbium laser to treat carious teeth has proven to have several advantages when compared to rotary instruments. The clinician is able to remove a minimal amount of tooth structure, thus minimizing the risk of pulpal exposure. The extremely short pulses of erbium lasers combined with an aerosolized water spray have been shown to cool the pulp as opposed to rotary instruments which may create heat that could lead to a pulpitis. Bonding to the lased surfaces is improved because the smear layer is removed, bleeding is controlled, and the lased tooth surface appears etched with open dentinal tubules. The laser also provides a bactericidal effect and the need for local anesthetics is eliminated or reduced. The use of the erbium laser to prepare cavity preparations can be done as quickly, or oftentimes more quickly, than using a rotary instruments. In addition, patients appreciate the absence of the high speed drill noise and vibration.</p>","PeriodicalId":76685,"journal":{"name":"The Journal of the Tennessee Dental Association","volume":"96 2","pages":"18-22"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Laser Versus Rotary Instrumentation- A Case Study.\",\"authors\":\"Paul Gregory,&nbsp;James Lea,&nbsp;Christopher Walinski,&nbsp;Denise Terese-Koch,&nbsp;Timothy Hottel,&nbsp;Dan Fields,&nbsp;Christopher Rodriguez\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of an erbium laser to treat carious teeth has proven to have several advantages when compared to rotary instruments. The clinician is able to remove a minimal amount of tooth structure, thus minimizing the risk of pulpal exposure. The extremely short pulses of erbium lasers combined with an aerosolized water spray have been shown to cool the pulp as opposed to rotary instruments which may create heat that could lead to a pulpitis. Bonding to the lased surfaces is improved because the smear layer is removed, bleeding is controlled, and the lased tooth surface appears etched with open dentinal tubules. The laser also provides a bactericidal effect and the need for local anesthetics is eliminated or reduced. The use of the erbium laser to prepare cavity preparations can be done as quickly, or oftentimes more quickly, than using a rotary instruments. In addition, patients appreciate the absence of the high speed drill noise and vibration.</p>\",\"PeriodicalId\":76685,\"journal\":{\"name\":\"The Journal of the Tennessee Dental Association\",\"volume\":\"96 2\",\"pages\":\"18-22\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of the Tennessee Dental Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of the Tennessee Dental Association","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

与旋转器械相比,使用铒激光治疗龋齿已被证明具有几个优点。临床医生能够移除最少量的牙齿结构,从而将牙髓暴露的风险降至最低。与旋转器械相反,极短脉冲的铒激光结合雾化水喷雾可以冷却牙髓,而旋转器械可能会产生热量,导致牙髓炎。与激光表面的结合得到改善,因为涂抹层被去除,出血得到控制,并且激光牙齿表面出现了开放的牙本质小管。激光还提供了杀菌效果,消除或减少了局部麻醉剂的需要。使用铒激光来准备腔体的准备可以和使用旋转仪器一样快,甚至更快。此外,患者对没有高速钻头的噪音和振动表示赞赏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Laser Versus Rotary Instrumentation- A Case Study.

The use of an erbium laser to treat carious teeth has proven to have several advantages when compared to rotary instruments. The clinician is able to remove a minimal amount of tooth structure, thus minimizing the risk of pulpal exposure. The extremely short pulses of erbium lasers combined with an aerosolized water spray have been shown to cool the pulp as opposed to rotary instruments which may create heat that could lead to a pulpitis. Bonding to the lased surfaces is improved because the smear layer is removed, bleeding is controlled, and the lased tooth surface appears etched with open dentinal tubules. The laser also provides a bactericidal effect and the need for local anesthetics is eliminated or reduced. The use of the erbium laser to prepare cavity preparations can be done as quickly, or oftentimes more quickly, than using a rotary instruments. In addition, patients appreciate the absence of the high speed drill noise and vibration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信