Federico Paredes, Arnaldo Estigarribia Bernal, Eduard Permanyer, Javier Poncela, Alejandro Ysasi, Enrique Herrero, Manuel Maynar, Rafael Llorens
{"title":"最新一代生物假体Trifecta™GT的早期体验。","authors":"Federico Paredes, Arnaldo Estigarribia Bernal, Eduard Permanyer, Javier Poncela, Alejandro Ysasi, Enrique Herrero, Manuel Maynar, Rafael Llorens","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The study aim was to assess the hemodynamic results and implantation technique for the latest-generation St. Jude Medical aortic valve bioprosthesis, the Trifecta™ GT, which was first marketed in 2016.</p><p><strong>Methods: </strong>The first 100 patients (mean age 74.59 ± 7.41 years) undergoing aortic valve replacement (AVR) with the Trifecta GT, whether associated or not with other procedures, were included and assessed. All patients underwent a baseline ultrasound scan prior to hospital discharge to monitor postoperative gradients and the presence of periprosthetic leakage.</p><p><strong>Results: </strong>The predominant valvular heart disease was aortic stenosis (85%). An isolated AVR was required in 43% of patients. The prosthesis sizes used were 19, 21, 23, 25, and 27 mm. The overall hospital mortality was 5%; all deaths occurred in patients with associated surgeries. Peak gradients measured prior to hospital discharge ranged from 17.95 mmHg to 10.95 mmHg for 19 mm and 27 mm prostheses, respectively; mean gradients were 9.94 and 6.18 mmHg for 19 mm and 27 mm prostheses, respectively. Neither implant-related complications nor significant periprosthetic leakages were recorded.</p><p><strong>Conclusions: </strong>Based on experience with patients, the Trifecta GT demonstrated an excellent hemodynamic performance after implantation, which involved a simple and safe technique. Further long-term studies to determine the durability of the prosthesis are required.</p>","PeriodicalId":50184,"journal":{"name":"Journal of Heart Valve Disease","volume":"26 6","pages":"721-727"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Early Experience with the Latest-Generation Biological Prosthesis, the Trifecta™ GT.\",\"authors\":\"Federico Paredes, Arnaldo Estigarribia Bernal, Eduard Permanyer, Javier Poncela, Alejandro Ysasi, Enrique Herrero, Manuel Maynar, Rafael Llorens\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The study aim was to assess the hemodynamic results and implantation technique for the latest-generation St. Jude Medical aortic valve bioprosthesis, the Trifecta™ GT, which was first marketed in 2016.</p><p><strong>Methods: </strong>The first 100 patients (mean age 74.59 ± 7.41 years) undergoing aortic valve replacement (AVR) with the Trifecta GT, whether associated or not with other procedures, were included and assessed. All patients underwent a baseline ultrasound scan prior to hospital discharge to monitor postoperative gradients and the presence of periprosthetic leakage.</p><p><strong>Results: </strong>The predominant valvular heart disease was aortic stenosis (85%). An isolated AVR was required in 43% of patients. The prosthesis sizes used were 19, 21, 23, 25, and 27 mm. The overall hospital mortality was 5%; all deaths occurred in patients with associated surgeries. Peak gradients measured prior to hospital discharge ranged from 17.95 mmHg to 10.95 mmHg for 19 mm and 27 mm prostheses, respectively; mean gradients were 9.94 and 6.18 mmHg for 19 mm and 27 mm prostheses, respectively. Neither implant-related complications nor significant periprosthetic leakages were recorded.</p><p><strong>Conclusions: </strong>Based on experience with patients, the Trifecta GT demonstrated an excellent hemodynamic performance after implantation, which involved a simple and safe technique. Further long-term studies to determine the durability of the prosthesis are required.</p>\",\"PeriodicalId\":50184,\"journal\":{\"name\":\"Journal of Heart Valve Disease\",\"volume\":\"26 6\",\"pages\":\"721-727\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Heart Valve Disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Heart Valve Disease","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Early Experience with the Latest-Generation Biological Prosthesis, the Trifecta™ GT.
Background: The study aim was to assess the hemodynamic results and implantation technique for the latest-generation St. Jude Medical aortic valve bioprosthesis, the Trifecta™ GT, which was first marketed in 2016.
Methods: The first 100 patients (mean age 74.59 ± 7.41 years) undergoing aortic valve replacement (AVR) with the Trifecta GT, whether associated or not with other procedures, were included and assessed. All patients underwent a baseline ultrasound scan prior to hospital discharge to monitor postoperative gradients and the presence of periprosthetic leakage.
Results: The predominant valvular heart disease was aortic stenosis (85%). An isolated AVR was required in 43% of patients. The prosthesis sizes used were 19, 21, 23, 25, and 27 mm. The overall hospital mortality was 5%; all deaths occurred in patients with associated surgeries. Peak gradients measured prior to hospital discharge ranged from 17.95 mmHg to 10.95 mmHg for 19 mm and 27 mm prostheses, respectively; mean gradients were 9.94 and 6.18 mmHg for 19 mm and 27 mm prostheses, respectively. Neither implant-related complications nor significant periprosthetic leakages were recorded.
Conclusions: Based on experience with patients, the Trifecta GT demonstrated an excellent hemodynamic performance after implantation, which involved a simple and safe technique. Further long-term studies to determine the durability of the prosthesis are required.
期刊介绍:
The Journal of Heart Valve Disease (ISSN 0966-8519) is the official journal of The Society for Heart Valve Disease. It is indexed/abstracted by Index Medicus, Medline, Medlar, PubMed, Science Citation Index, Scisearch, Research Alert, Biomedical Products, Current Contents/Clinical Medicine. It is issued bi-monthly in one indexed volume by ICR Publishers Ltd., Crispin House, 12A South Approach, Moor Park, Northwood HA6 2ET, United Kingdom. This paper meets the requirements of ANSI standard Z39.48-1992 (Permanence of Paper).