在存在加性干扰效应的情况下,采用非线性标准加法法进行可靠标定。

IF 1.7 4区 化学 Q3 CHEMISTRY, MULTIDISCIPLINARY
Monatshefte Fur Chemie Pub Date : 2018-01-01 Epub Date: 2018-08-07 DOI:10.1007/s00706-018-2203-1
Marcin Wieczorek, Marek Dębosz, Paweł Świt, Aleksandra Piech, Joanna Kasperek, Paweł Kościelniak
{"title":"在存在加性干扰效应的情况下,采用非线性标准加法法进行可靠标定。","authors":"Marcin Wieczorek,&nbsp;Marek Dębosz,&nbsp;Paweł Świt,&nbsp;Aleksandra Piech,&nbsp;Joanna Kasperek,&nbsp;Paweł Kościelniak","doi":"10.1007/s00706-018-2203-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>The possibility of adapting the Standard Addition Method (SAM) to calibration in very difficult analytical conditions, namely when there is a need to determine an analyte with the use of nonlinear calibration graph and in the presence of matrix components causing additive interference effect, is investigated. To this aim the SAM in the common version and the Chemical H-point Standard Addition Method (C-HPSAM) realized by the flow injection technique were applied. Specifically, a flow manifold was used for construction of a set of nonlinear calibration graphs in different chemical conditions. As the graphs were intersected indicating both the additive interference effect and the analytical result free of this effect, the analyte concentration in the sample was able to be obtained with improved accuracy. The applicability of this approach was verified on the example of spectrophotometric determination of paracetamol in pharmaceuticals and of total acidity in wines. The C-HPSAM method enabled complete compensation of the additive effect and obtaining analytical results at a relative error not exceeding 6.0%.</p><p><strong>Graphical abstract: </strong></p>","PeriodicalId":18766,"journal":{"name":"Monatshefte Fur Chemie","volume":"149 9","pages":"1567-1572"},"PeriodicalIF":1.7000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s00706-018-2203-1","citationCount":"8","resultStr":"{\"title\":\"Reliable calibration by nonlinear standard addition method in the presence of additive interference effects.\",\"authors\":\"Marcin Wieczorek,&nbsp;Marek Dębosz,&nbsp;Paweł Świt,&nbsp;Aleksandra Piech,&nbsp;Joanna Kasperek,&nbsp;Paweł Kościelniak\",\"doi\":\"10.1007/s00706-018-2203-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Abstract: </strong>The possibility of adapting the Standard Addition Method (SAM) to calibration in very difficult analytical conditions, namely when there is a need to determine an analyte with the use of nonlinear calibration graph and in the presence of matrix components causing additive interference effect, is investigated. To this aim the SAM in the common version and the Chemical H-point Standard Addition Method (C-HPSAM) realized by the flow injection technique were applied. Specifically, a flow manifold was used for construction of a set of nonlinear calibration graphs in different chemical conditions. As the graphs were intersected indicating both the additive interference effect and the analytical result free of this effect, the analyte concentration in the sample was able to be obtained with improved accuracy. The applicability of this approach was verified on the example of spectrophotometric determination of paracetamol in pharmaceuticals and of total acidity in wines. The C-HPSAM method enabled complete compensation of the additive effect and obtaining analytical results at a relative error not exceeding 6.0%.</p><p><strong>Graphical abstract: </strong></p>\",\"PeriodicalId\":18766,\"journal\":{\"name\":\"Monatshefte Fur Chemie\",\"volume\":\"149 9\",\"pages\":\"1567-1572\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s00706-018-2203-1\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Monatshefte Fur Chemie\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1007/s00706-018-2203-1\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/8/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Monatshefte Fur Chemie","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00706-018-2203-1","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/8/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 8

摘要

摘要:研究了标准添加法(SAM)在非常困难的分析条件下,即需要使用非线性校准图确定分析物和存在引起加性干扰效应的矩阵成分时,适用于校准的可能性。为此,采用了通用版的化学h点标准添加法和流动注射技术实现的化学h点标准添加法(C-HPSAM)。具体而言,利用流动流形构造了不同化学条件下的一组非线性标定图。由于图形相交,表明加性干扰效应和分析结果没有这种影响,因此能够以更高的精度获得样品中的分析物浓度。以分光光度法测定药品中的扑热息痛和葡萄酒中的总酸度为例,验证了该方法的适用性。C-HPSAM方法完全补偿了加性效应,得到的分析结果相对误差不超过6.0%。图形化的简介:
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Reliable calibration by nonlinear standard addition method in the presence of additive interference effects.

Reliable calibration by nonlinear standard addition method in the presence of additive interference effects.

Reliable calibration by nonlinear standard addition method in the presence of additive interference effects.

Reliable calibration by nonlinear standard addition method in the presence of additive interference effects.

Abstract: The possibility of adapting the Standard Addition Method (SAM) to calibration in very difficult analytical conditions, namely when there is a need to determine an analyte with the use of nonlinear calibration graph and in the presence of matrix components causing additive interference effect, is investigated. To this aim the SAM in the common version and the Chemical H-point Standard Addition Method (C-HPSAM) realized by the flow injection technique were applied. Specifically, a flow manifold was used for construction of a set of nonlinear calibration graphs in different chemical conditions. As the graphs were intersected indicating both the additive interference effect and the analytical result free of this effect, the analyte concentration in the sample was able to be obtained with improved accuracy. The applicability of this approach was verified on the example of spectrophotometric determination of paracetamol in pharmaceuticals and of total acidity in wines. The C-HPSAM method enabled complete compensation of the additive effect and obtaining analytical results at a relative error not exceeding 6.0%.

Graphical abstract:

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Monatshefte Fur Chemie
Monatshefte Fur Chemie 化学-化学综合
CiteScore
3.70
自引率
5.60%
发文量
116
审稿时长
3.3 months
期刊介绍: "Monatshefte für Chemie/Chemical Monthly" was originally conceived as an Austrian journal of chemistry. It has evolved into an international journal covering all branches of chemistry. Featuring the most recent advances in research in analytical chemistry, biochemistry, inorganic, medicinal, organic, physical, structural, and theoretical chemistry, Chemical Monthly publishes refereed original papers and a section entitled "Short Communications". Reviews, symposia in print, and issues devoted to special fields will also be considered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信