过度肥胖者肾脏组织谐波与常规b超图像质量的比较。

Electronic Physician Pub Date : 2018-07-25 eCollection Date: 2018-07-01 DOI:10.19082/7095
Hossein Rezaei-Dalouei, Farrokh Seilanian-Toosi, Sirous Nekooei, Behrouz Davachi, Azita Azarian, Bita Abbasi
{"title":"过度肥胖者肾脏组织谐波与常规b超图像质量的比较。","authors":"Hossein Rezaei-Dalouei,&nbsp;Farrokh Seilanian-Toosi,&nbsp;Sirous Nekooei,&nbsp;Behrouz Davachi,&nbsp;Azita Azarian,&nbsp;Bita Abbasi","doi":"10.19082/7095","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Increased subcutaneous fat thickness and depth of target organs in over-obese patients, results in weak signals and inadequate images. Tissue harmonic imaging has been used widely in obese patients and is believed to result in higher quality images. This superiority is not proved in modern machines with improved image quality in conventional mode.</p><p><strong>Objective: </strong>To compare the image quality between conventional and tissue harmonic ultrasound images.</p><p><strong>Methods: </strong>This cross-sectional study was carried out from March 2015 to June 2016. Seventy-six over-obese patients referred to Ghaem Hospital (Mashhad, Iran) for weight-correction surgeries, were enrolled into the study. Conventional and tissue harmonic images of their kidneys were blinded and compared back-to-back by four expert radiologists. Data were analyzed by SPSS version 16, using Cochrane's Q test.</p><p><strong>Results: </strong>All raters reported image quality to be better in tissue harmonic compared to fundamental frequency ultrasound (p=0.000, Cochrane's Q test). Although better image quality in tissue harmonic mode was reported by the four raters, there was weak inter-observer agreement (p=0.081 for right kidney and p=0.21 for left kidney).</p><p><strong>Conclusion: </strong>Advances in ultrasound equipment and the introduction of tissue harmonic imaging can improve the diagnostic performance in over-obese patients and this mode of imaging should be used whenever evaluating over-obese subjects.</p>","PeriodicalId":11603,"journal":{"name":"Electronic Physician","volume":"10 7","pages":"7095-7100"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/36/38/epj-10-7095.PMC6092138.pdf","citationCount":"0","resultStr":"{\"title\":\"Comparing the image quality of tissue harmonic and conventional B-mode ultrasound of kidney in over-obese individuals.\",\"authors\":\"Hossein Rezaei-Dalouei,&nbsp;Farrokh Seilanian-Toosi,&nbsp;Sirous Nekooei,&nbsp;Behrouz Davachi,&nbsp;Azita Azarian,&nbsp;Bita Abbasi\",\"doi\":\"10.19082/7095\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Increased subcutaneous fat thickness and depth of target organs in over-obese patients, results in weak signals and inadequate images. Tissue harmonic imaging has been used widely in obese patients and is believed to result in higher quality images. This superiority is not proved in modern machines with improved image quality in conventional mode.</p><p><strong>Objective: </strong>To compare the image quality between conventional and tissue harmonic ultrasound images.</p><p><strong>Methods: </strong>This cross-sectional study was carried out from March 2015 to June 2016. Seventy-six over-obese patients referred to Ghaem Hospital (Mashhad, Iran) for weight-correction surgeries, were enrolled into the study. Conventional and tissue harmonic images of their kidneys were blinded and compared back-to-back by four expert radiologists. Data were analyzed by SPSS version 16, using Cochrane's Q test.</p><p><strong>Results: </strong>All raters reported image quality to be better in tissue harmonic compared to fundamental frequency ultrasound (p=0.000, Cochrane's Q test). Although better image quality in tissue harmonic mode was reported by the four raters, there was weak inter-observer agreement (p=0.081 for right kidney and p=0.21 for left kidney).</p><p><strong>Conclusion: </strong>Advances in ultrasound equipment and the introduction of tissue harmonic imaging can improve the diagnostic performance in over-obese patients and this mode of imaging should be used whenever evaluating over-obese subjects.</p>\",\"PeriodicalId\":11603,\"journal\":{\"name\":\"Electronic Physician\",\"volume\":\"10 7\",\"pages\":\"7095-7100\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/36/38/epj-10-7095.PMC6092138.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electronic Physician\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.19082/7095\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/7/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electronic Physician","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19082/7095","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/7/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:过度肥胖患者靶器官皮下脂肪厚度和深度增加,导致信号弱和图像不充分。组织谐波成像已广泛应用于肥胖患者,并被认为可以获得更高质量的图像。这种优越性在传统模式下提高图像质量的现代机器中没有得到证明。目的:比较常规超声与组织谐波超声图像的图像质量。方法:本横断面研究于2015年3月至2016年6月进行。76名到伊朗马什哈德Ghaem医院接受体重矫正手术的过度肥胖患者被纳入研究。他们肾脏的常规图像和组织谐波图像是盲法的,由四位放射专家背靠背进行比较。数据分析采用SPSS 16版,采用Cochrane’s Q检验。结果:与基频超声相比,所有评分者报告组织谐波图像质量更好(p=0.000, Cochrane’s Q检验)。尽管四名评分者报告了组织谐波模式下更好的图像质量,但观察者之间的一致性很弱(右肾p=0.081,左肾p=0.21)。结论:超声设备的进步和组织谐波成像的引入可以提高对过度肥胖患者的诊断效果,在评估过度肥胖患者时应采用这种成像模式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparing the image quality of tissue harmonic and conventional B-mode ultrasound of kidney in over-obese individuals.

Comparing the image quality of tissue harmonic and conventional B-mode ultrasound of kidney in over-obese individuals.

Background: Increased subcutaneous fat thickness and depth of target organs in over-obese patients, results in weak signals and inadequate images. Tissue harmonic imaging has been used widely in obese patients and is believed to result in higher quality images. This superiority is not proved in modern machines with improved image quality in conventional mode.

Objective: To compare the image quality between conventional and tissue harmonic ultrasound images.

Methods: This cross-sectional study was carried out from March 2015 to June 2016. Seventy-six over-obese patients referred to Ghaem Hospital (Mashhad, Iran) for weight-correction surgeries, were enrolled into the study. Conventional and tissue harmonic images of their kidneys were blinded and compared back-to-back by four expert radiologists. Data were analyzed by SPSS version 16, using Cochrane's Q test.

Results: All raters reported image quality to be better in tissue harmonic compared to fundamental frequency ultrasound (p=0.000, Cochrane's Q test). Although better image quality in tissue harmonic mode was reported by the four raters, there was weak inter-observer agreement (p=0.081 for right kidney and p=0.21 for left kidney).

Conclusion: Advances in ultrasound equipment and the introduction of tissue harmonic imaging can improve the diagnostic performance in over-obese patients and this mode of imaging should be used whenever evaluating over-obese subjects.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
6
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信