Manohar Bance, Andrzej Zarowski, Robert A Adamson, Jan W Casselman
{"title":"耳科的新成像方式。","authors":"Manohar Bance, Andrzej Zarowski, Robert A Adamson, Jan W Casselman","doi":"10.1159/000485576","DOIUrl":null,"url":null,"abstract":"<p><p>Despite steady improvements in cross-sectional imaging of the ear, current technologies still have limitations in terms of resolution, diagnosis, functional assessment and safety. In this chapter, state-of-the-art imaging techniques in current clinical practice are presented including cone-beam computerized tomography, non-echo planar imaging magnetic resonance imaging, imaging for labyrinthine hydrops and imaging of the central auditory pathways. Potential future imaging modalities are also presented, including optical coherence tomography (OCT) and high-frequency ultrasound (HFUS) of the ear. These experimental modalities offer new opportunities for the assessment of ear structure and function. For example, middle ear structures can be visualized through the tympanic membrane, basilar membrane vibrations can be assessed through the round window and the passage of cochlear implants can be assessed in decalcified cochlear. Functional assessment of the middle ear using Doppler techniques are also discussed, including measurement of tympanic membrane and middle ear vibration amplitudes, visualization of dynamic changes, such as tensor tympani movements and movement of the tympanic membrane with breathing. These new modalities currently have limitations that preclude mainstream clinical use. For example, OCT is limited by the optical scattering of the thickened tympanic membrane and HFUS needs a coupling medium such as gel or fluid from the transducer to the imaged structure although it can visualize through thicker tissues. Nevertheless, further development of these novel techniques may provide an enhanced ability to assess the ear in conjunction with current technologies.</p>","PeriodicalId":39848,"journal":{"name":"Advances in Oto-Rhino-Laryngology","volume":"81 ","pages":"1-13"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000485576","citationCount":"5","resultStr":"{\"title\":\"New Imaging Modalities in Otology.\",\"authors\":\"Manohar Bance, Andrzej Zarowski, Robert A Adamson, Jan W Casselman\",\"doi\":\"10.1159/000485576\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Despite steady improvements in cross-sectional imaging of the ear, current technologies still have limitations in terms of resolution, diagnosis, functional assessment and safety. In this chapter, state-of-the-art imaging techniques in current clinical practice are presented including cone-beam computerized tomography, non-echo planar imaging magnetic resonance imaging, imaging for labyrinthine hydrops and imaging of the central auditory pathways. Potential future imaging modalities are also presented, including optical coherence tomography (OCT) and high-frequency ultrasound (HFUS) of the ear. These experimental modalities offer new opportunities for the assessment of ear structure and function. For example, middle ear structures can be visualized through the tympanic membrane, basilar membrane vibrations can be assessed through the round window and the passage of cochlear implants can be assessed in decalcified cochlear. Functional assessment of the middle ear using Doppler techniques are also discussed, including measurement of tympanic membrane and middle ear vibration amplitudes, visualization of dynamic changes, such as tensor tympani movements and movement of the tympanic membrane with breathing. These new modalities currently have limitations that preclude mainstream clinical use. For example, OCT is limited by the optical scattering of the thickened tympanic membrane and HFUS needs a coupling medium such as gel or fluid from the transducer to the imaged structure although it can visualize through thicker tissues. Nevertheless, further development of these novel techniques may provide an enhanced ability to assess the ear in conjunction with current technologies.</p>\",\"PeriodicalId\":39848,\"journal\":{\"name\":\"Advances in Oto-Rhino-Laryngology\",\"volume\":\"81 \",\"pages\":\"1-13\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000485576\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Oto-Rhino-Laryngology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000485576\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/4/6 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Oto-Rhino-Laryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000485576","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/4/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Despite steady improvements in cross-sectional imaging of the ear, current technologies still have limitations in terms of resolution, diagnosis, functional assessment and safety. In this chapter, state-of-the-art imaging techniques in current clinical practice are presented including cone-beam computerized tomography, non-echo planar imaging magnetic resonance imaging, imaging for labyrinthine hydrops and imaging of the central auditory pathways. Potential future imaging modalities are also presented, including optical coherence tomography (OCT) and high-frequency ultrasound (HFUS) of the ear. These experimental modalities offer new opportunities for the assessment of ear structure and function. For example, middle ear structures can be visualized through the tympanic membrane, basilar membrane vibrations can be assessed through the round window and the passage of cochlear implants can be assessed in decalcified cochlear. Functional assessment of the middle ear using Doppler techniques are also discussed, including measurement of tympanic membrane and middle ear vibration amplitudes, visualization of dynamic changes, such as tensor tympani movements and movement of the tympanic membrane with breathing. These new modalities currently have limitations that preclude mainstream clinical use. For example, OCT is limited by the optical scattering of the thickened tympanic membrane and HFUS needs a coupling medium such as gel or fluid from the transducer to the imaged structure although it can visualize through thicker tissues. Nevertheless, further development of these novel techniques may provide an enhanced ability to assess the ear in conjunction with current technologies.
期刊介绍:
Material for each volume in this series has been skillfully selected to document the most active areas of otorhinolaryngology and related specialties, such as neuro-otology and oncology. The series reproduces results from basic research and clinical studies pertaining to the pathophysiology, diagnosis, clinical symptoms, course, prognosis and therapy of a variety of ear, nose and throat disorders. The numerous papers correlating basic research findings and clinical applications are of immense value to all specialists engaged in the ongoing efforts to improve management of these disorders. Acting as a voice for its field, the series has also been instrumental in developing subspecialities into established specialities.