定量DCE-MRI的可变性:来源和解决方案。

Journal of nature and science Pub Date : 2018-01-01
Harrison Kim
{"title":"定量DCE-MRI的可变性:来源和解决方案。","authors":"Harrison Kim","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>DCE-MRI has been extensively used for diagnosis, prognosis and therapy monitoring of various diseases including cancer. However, it has been reported that the perfusion parameters measured by DCE-MRI largely vary across different research sites, preventing data comparison in multi-institutional clinical trials. Recently, novel perfusion phantoms have been developed to correct scanner-driven errors, enabling quality assurance of quantitative DCE-MRI measurement. However, the sources for the variability in quantitating perfusion parameters are not only MRI scanners but also software packages and imaging protocols set by the operators. In this manuscript, the various sources influencing the variability in quantitative DCE-MRI measurement are reviewed, and the proper solutions to minimize those are discussed.</p>","PeriodicalId":73848,"journal":{"name":"Journal of nature and science","volume":"4 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5841165/pdf/nihms938928.pdf","citationCount":"0","resultStr":"{\"title\":\"Variability in Quantitative DCE-MRI: Sources and Solutions.\",\"authors\":\"Harrison Kim\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>DCE-MRI has been extensively used for diagnosis, prognosis and therapy monitoring of various diseases including cancer. However, it has been reported that the perfusion parameters measured by DCE-MRI largely vary across different research sites, preventing data comparison in multi-institutional clinical trials. Recently, novel perfusion phantoms have been developed to correct scanner-driven errors, enabling quality assurance of quantitative DCE-MRI measurement. However, the sources for the variability in quantitating perfusion parameters are not only MRI scanners but also software packages and imaging protocols set by the operators. In this manuscript, the various sources influencing the variability in quantitative DCE-MRI measurement are reviewed, and the proper solutions to minimize those are discussed.</p>\",\"PeriodicalId\":73848,\"journal\":{\"name\":\"Journal of nature and science\",\"volume\":\"4 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5841165/pdf/nihms938928.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of nature and science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nature and science","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

DCE-MRI已广泛应用于包括癌症在内的多种疾病的诊断、预后和治疗监测。然而,据报道,DCE-MRI测量的灌注参数在不同的研究地点差异很大,妨碍了多机构临床试验的数据比较。最近,已经开发出新的灌注幻象来纠正扫描仪驱动的错误,从而保证定量DCE-MRI测量的质量。然而,定量灌注参数的可变性来源不仅是MRI扫描仪,还包括软件包和操作员设置的成像协议。本文回顾了影响定量DCE-MRI测量变异性的各种来源,并讨论了最小化这些来源的适当解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Variability in Quantitative DCE-MRI: Sources and Solutions.

Variability in Quantitative DCE-MRI: Sources and Solutions.

DCE-MRI has been extensively used for diagnosis, prognosis and therapy monitoring of various diseases including cancer. However, it has been reported that the perfusion parameters measured by DCE-MRI largely vary across different research sites, preventing data comparison in multi-institutional clinical trials. Recently, novel perfusion phantoms have been developed to correct scanner-driven errors, enabling quality assurance of quantitative DCE-MRI measurement. However, the sources for the variability in quantitating perfusion parameters are not only MRI scanners but also software packages and imaging protocols set by the operators. In this manuscript, the various sources influencing the variability in quantitative DCE-MRI measurement are reviewed, and the proper solutions to minimize those are discussed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信