穴居人人体模型的建立:下肢对垂直加速载荷亚损伤反应的验证。

Q2 Medicine
Kent Butz, Chad Spurlock, Rajarshi Roy, Cameron Bell, Paul Barrett, Aaron Ward, Xudong Xiao, Allen Shirley, Colin Welch, Kevin Lister
{"title":"穴居人人体模型的建立:下肢对垂直加速载荷亚损伤反应的验证。","authors":"Kent Butz,&nbsp;Chad Spurlock,&nbsp;Rajarshi Roy,&nbsp;Cameron Bell,&nbsp;Paul Barrett,&nbsp;Aaron Ward,&nbsp;Xudong Xiao,&nbsp;Allen Shirley,&nbsp;Colin Welch,&nbsp;Kevin Lister","doi":"10.4271/2017-22-0007","DOIUrl":null,"url":null,"abstract":"<p><p>Improving injury prediction accuracy and fidelity for mounted Warfighters has become an area of focus for the U.S. military in response to improvised explosive device (IED) use in both Iraq and Afghanistan. Although the Hybrid III anthropomorphic test device (ATD) has historically been used for crew injury analysis, it is only capable of predicting a few select skeletal injuries. The Computational Anthropomorphic Virtual Experiment Man (CAVEMAN) human body model is being developed to expand the injury analysis capability to both skeletal and soft tissues. The CAVEMAN model is built upon the Zygote 50<sup>th</sup> percentile male human CAD model and uses a finite element modeling approach developed for high performance computing (HPC). The lower extremity subset of the CAVEMAN human body model presented herein includes: 28 bones, 26 muscles, 40 ligaments, fascia, cartilage and skin. Sensitivity studies have been conducted with the CAVEMAN lower extremity model to determine the structures critical for load transmission through the leg in the underbody blast (UBB) environment. An evaluation of the CAVEMAN lower extremity biofidelity was also carried out using 14 unique data sets derived by the Warrior Injury Assessment Manikin (WIAMan) program cadaveric lower leg testing. Extension of the CAVEMAN lower extremity model into anatomical tissue failure will provide additional injury prediction capabilities, beyond what is currently achievable using ATDs, to improve occupant survivability analyses within military vehicles.</p>","PeriodicalId":35289,"journal":{"name":"Stapp car crash journal","volume":"61 ","pages":"175-209"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4271/2017-22-0007","citationCount":"3","resultStr":"{\"title\":\"Development of the CAVEMAN Human Body Model: Validation of Lower Extremity Sub-Injurious Response to Vertical Accelerative Loading.\",\"authors\":\"Kent Butz,&nbsp;Chad Spurlock,&nbsp;Rajarshi Roy,&nbsp;Cameron Bell,&nbsp;Paul Barrett,&nbsp;Aaron Ward,&nbsp;Xudong Xiao,&nbsp;Allen Shirley,&nbsp;Colin Welch,&nbsp;Kevin Lister\",\"doi\":\"10.4271/2017-22-0007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Improving injury prediction accuracy and fidelity for mounted Warfighters has become an area of focus for the U.S. military in response to improvised explosive device (IED) use in both Iraq and Afghanistan. Although the Hybrid III anthropomorphic test device (ATD) has historically been used for crew injury analysis, it is only capable of predicting a few select skeletal injuries. The Computational Anthropomorphic Virtual Experiment Man (CAVEMAN) human body model is being developed to expand the injury analysis capability to both skeletal and soft tissues. The CAVEMAN model is built upon the Zygote 50<sup>th</sup> percentile male human CAD model and uses a finite element modeling approach developed for high performance computing (HPC). The lower extremity subset of the CAVEMAN human body model presented herein includes: 28 bones, 26 muscles, 40 ligaments, fascia, cartilage and skin. Sensitivity studies have been conducted with the CAVEMAN lower extremity model to determine the structures critical for load transmission through the leg in the underbody blast (UBB) environment. An evaluation of the CAVEMAN lower extremity biofidelity was also carried out using 14 unique data sets derived by the Warrior Injury Assessment Manikin (WIAMan) program cadaveric lower leg testing. Extension of the CAVEMAN lower extremity model into anatomical tissue failure will provide additional injury prediction capabilities, beyond what is currently achievable using ATDs, to improve occupant survivability analyses within military vehicles.</p>\",\"PeriodicalId\":35289,\"journal\":{\"name\":\"Stapp car crash journal\",\"volume\":\"61 \",\"pages\":\"175-209\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4271/2017-22-0007\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Stapp car crash journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4271/2017-22-0007\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stapp car crash journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4271/2017-22-0007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 3

摘要

提高骑兵损伤预测的准确性和保真度已经成为美军应对伊拉克和阿富汗简易爆炸装置(IED)使用的一个重点领域。尽管Hybrid III拟人化测试装置(ATD)在历史上曾用于乘员损伤分析,但它只能预测少数几种选定的骨骼损伤。计算拟人虚拟实验人(CAVEMAN)人体模型的开发是为了将损伤分析能力扩展到骨骼和软组织。CAVEMAN模型建立在Zygote第50百分位男性CAD模型的基础上,并使用为高性能计算(HPC)开发的有限元建模方法。本文提出的穴人人体模型的下肢亚群包括:28块骨骼、26块肌肉、40块韧带、筋膜、软骨和皮肤。对CAVEMAN下肢模型进行了敏感性研究,以确定在体下爆炸(UBB)环境中通过腿部传递载荷的关键结构。利用勇士损伤评估人体模型(WIAMan)项目的尸体下肢测试得出的14个独特数据集,对穴人下肢生物保真度进行了评估。将CAVEMAN下肢模型扩展到解剖组织损伤,将提供额外的损伤预测能力,超越目前使用ATDs所能实现的,以提高军用车辆乘员的生存能力分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of the CAVEMAN Human Body Model: Validation of Lower Extremity Sub-Injurious Response to Vertical Accelerative Loading.

Improving injury prediction accuracy and fidelity for mounted Warfighters has become an area of focus for the U.S. military in response to improvised explosive device (IED) use in both Iraq and Afghanistan. Although the Hybrid III anthropomorphic test device (ATD) has historically been used for crew injury analysis, it is only capable of predicting a few select skeletal injuries. The Computational Anthropomorphic Virtual Experiment Man (CAVEMAN) human body model is being developed to expand the injury analysis capability to both skeletal and soft tissues. The CAVEMAN model is built upon the Zygote 50th percentile male human CAD model and uses a finite element modeling approach developed for high performance computing (HPC). The lower extremity subset of the CAVEMAN human body model presented herein includes: 28 bones, 26 muscles, 40 ligaments, fascia, cartilage and skin. Sensitivity studies have been conducted with the CAVEMAN lower extremity model to determine the structures critical for load transmission through the leg in the underbody blast (UBB) environment. An evaluation of the CAVEMAN lower extremity biofidelity was also carried out using 14 unique data sets derived by the Warrior Injury Assessment Manikin (WIAMan) program cadaveric lower leg testing. Extension of the CAVEMAN lower extremity model into anatomical tissue failure will provide additional injury prediction capabilities, beyond what is currently achievable using ATDs, to improve occupant survivability analyses within military vehicles.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Stapp car crash journal
Stapp car crash journal Medicine-Medicine (all)
CiteScore
3.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信