{"title":"重度主动脉瓣狭窄合并心源性休克患者经导管主动脉瓣置换术前使用Impella 5.0","authors":"Dustin W Johnson,&nbsp;John P ErwinIII","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The use of transcatheter aortic valve replacement (TAVR) has risen dramatically during the past decade. Notably, the procedure can reduce symptoms and improve prognosis in patients who would otherwise be excluded from intervention due to prohibitive surgical risk. During the same time period, the use of percutaneous mechanical circulatory support devices for patients with severe left ventricular dysfunction, including the Impella System (Abiomed, Inc., Danvers, MA, USA), has also increased. These devices provide superior hemodynamic effects compared to intra-aortic balloon pumping. However, data relating to use of the Impella in patients with both severe left ventricular dysfunction and significant aortic valve disease are limited. Herein is presented the case of a 59-year-old man with severe aortic stenosis and cardiogenic shock who was treated successfully with an Impella 5.0 as a temporizing measure prior to TAVR. A brief review is also provided of the use of mechanical circulatory support devices in this subset of patients. Video 1: Transesophageal echocardiography video demonstrating stenotic aortic valve pre-intervention in side-by-side long and short axes. Video 2: Transthoracic echocardiography video, parasternal short axis, demonstrating Impella 5 in the left ventricle. Video 3: Fluoroscopy video demonstrating deployment of the Edwards SAPIEN transcatheter aortic valve. Video 4: Transesophageal echocardiography video showing the Edwards SAPIEN transcatheter aortic valve in long axis. Video 5: Transesophageal echocardiography video showing the Edwards SAPIEN transcatheter aortic valve in short axis.</p>","PeriodicalId":50184,"journal":{"name":"Journal of Heart Valve Disease","volume":"26 4","pages":"485-487"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of Impella 5.0 Prior to Transcatheter Aortic Valve Replacement in a Patient with Severe Aortic Stenosis and Cardiogenic Shock.\",\"authors\":\"Dustin W Johnson,&nbsp;John P ErwinIII\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of transcatheter aortic valve replacement (TAVR) has risen dramatically during the past decade. Notably, the procedure can reduce symptoms and improve prognosis in patients who would otherwise be excluded from intervention due to prohibitive surgical risk. During the same time period, the use of percutaneous mechanical circulatory support devices for patients with severe left ventricular dysfunction, including the Impella System (Abiomed, Inc., Danvers, MA, USA), has also increased. These devices provide superior hemodynamic effects compared to intra-aortic balloon pumping. However, data relating to use of the Impella in patients with both severe left ventricular dysfunction and significant aortic valve disease are limited. Herein is presented the case of a 59-year-old man with severe aortic stenosis and cardiogenic shock who was treated successfully with an Impella 5.0 as a temporizing measure prior to TAVR. A brief review is also provided of the use of mechanical circulatory support devices in this subset of patients. Video 1: Transesophageal echocardiography video demonstrating stenotic aortic valve pre-intervention in side-by-side long and short axes. Video 2: Transthoracic echocardiography video, parasternal short axis, demonstrating Impella 5 in the left ventricle. Video 3: Fluoroscopy video demonstrating deployment of the Edwards SAPIEN transcatheter aortic valve. Video 4: Transesophageal echocardiography video showing the Edwards SAPIEN transcatheter aortic valve in long axis. Video 5: Transesophageal echocardiography video showing the Edwards SAPIEN transcatheter aortic valve in short axis.</p>\",\"PeriodicalId\":50184,\"journal\":{\"name\":\"Journal of Heart Valve Disease\",\"volume\":\"26 4\",\"pages\":\"485-487\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Heart Valve Disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Heart Valve Disease","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

在过去的十年中,经导管主动脉瓣置换术(TAVR)的使用急剧上升。值得注意的是,对于那些因手术风险过高而被排除在干预之外的患者,该手术可以减轻症状并改善预后。在同一时期,严重左心室功能障碍患者使用经皮机械循环支持装置,包括Impella系统(Abiomed, Inc., Danvers, MA, USA),也有所增加。与主动脉内球囊泵送相比,这些装置提供了更好的血流动力学效果。然而,关于Impella在严重左心室功能障碍和严重主动脉瓣疾病患者中使用的数据有限。本文报告一名59岁男性严重主动脉瓣狭窄和心源性休克的病例,在TAVR之前使用Impella 5.0作为临时措施成功治疗。简要回顾了在这类患者中使用机械循环支持装置的情况。视频1:经食管超声心动图视频显示主动脉瓣狭窄前干预并排长轴和短轴。视频2:经胸超声心动图视频,胸骨旁短轴,显示左心室第5轮。视频3:透视显示Edwards SAPIEN经导管主动脉瓣的部署。视频4:经食管超声心动图视频显示长轴的Edwards SAPIEN经导管主动脉瓣。视频5:经食管超声心动图视频显示爱德华兹SAPIEN经导管主动脉瓣短轴。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Use of Impella 5.0 Prior to Transcatheter Aortic Valve Replacement in a Patient with Severe Aortic Stenosis and Cardiogenic Shock.

The use of transcatheter aortic valve replacement (TAVR) has risen dramatically during the past decade. Notably, the procedure can reduce symptoms and improve prognosis in patients who would otherwise be excluded from intervention due to prohibitive surgical risk. During the same time period, the use of percutaneous mechanical circulatory support devices for patients with severe left ventricular dysfunction, including the Impella System (Abiomed, Inc., Danvers, MA, USA), has also increased. These devices provide superior hemodynamic effects compared to intra-aortic balloon pumping. However, data relating to use of the Impella in patients with both severe left ventricular dysfunction and significant aortic valve disease are limited. Herein is presented the case of a 59-year-old man with severe aortic stenosis and cardiogenic shock who was treated successfully with an Impella 5.0 as a temporizing measure prior to TAVR. A brief review is also provided of the use of mechanical circulatory support devices in this subset of patients. Video 1: Transesophageal echocardiography video demonstrating stenotic aortic valve pre-intervention in side-by-side long and short axes. Video 2: Transthoracic echocardiography video, parasternal short axis, demonstrating Impella 5 in the left ventricle. Video 3: Fluoroscopy video demonstrating deployment of the Edwards SAPIEN transcatheter aortic valve. Video 4: Transesophageal echocardiography video showing the Edwards SAPIEN transcatheter aortic valve in long axis. Video 5: Transesophageal echocardiography video showing the Edwards SAPIEN transcatheter aortic valve in short axis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Heart Valve Disease
Journal of Heart Valve Disease 医学-心血管系统
CiteScore
1.00
自引率
0.00%
发文量
0
审稿时长
4-8 weeks
期刊介绍: The Journal of Heart Valve Disease (ISSN 0966-8519) is the official journal of The Society for Heart Valve Disease. It is indexed/abstracted by Index Medicus, Medline, Medlar, PubMed, Science Citation Index, Scisearch, Research Alert, Biomedical Products, Current Contents/Clinical Medicine. It is issued bi-monthly in one indexed volume by ICR Publishers Ltd., Crispin House, 12A South Approach, Moor Park, Northwood HA6 2ET, United Kingdom. This paper meets the requirements of ANSI standard Z39.48-1992 (Permanence of Paper).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信