{"title":"高剂量血管加压药物治疗感染性休克患者两种微创血流动力学测量方法的一致性评估。初步研究。","authors":"Oana Antal, Mihai Mărginean, Natalia Hagău","doi":"10.21454/rjaic.7518.242.min","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Minimally invasive hemodynamic monitoring is still controversial among the methods used to assess the hemodynamic profile of the septic shock patient. The aim of this study was to test the level of agreement between two different devices.</p><p><strong>Methods: </strong>We collected 385 data entries during 12-hour intervals from four critically ill patients with septic shock and high doses of vasoactive therapy using two minimally invasive methods at the same time: Vigileo™ device which uses the pulse contour principle, and EV1000™ monitoring platform which uses the transpulmonary thermodilution principle. The studied parameters were Stroke Volume (SV), Cardiac Output (CO) and Mean Arterial Pressure (MAP). We tested the agreement by performing the visual examination of data patterns using graphs and studying the bias, limits of agreement and creating Bland-Altman plots. For assessing the systematic, proportional and random differences, we computed a Passing-Bablock regression with the CUSUM test for linearity.</p><p><strong>Results: </strong>The one sample t-Test for the differences between the two methods against the null value was statistically significant for the studied parameters (p < 0.0001). The Bland-Altman analysis found no agreement between the data obtained using the two techniques, with calculated error percent as high as 88.28% for SV, 82.02% for CO and 42.06% for MAP. The Passing-Bablock regression analysis tested positive for systematic differences, but this could not be accounted for.</p><p><strong>Conclusion: </strong>We found no agreement between data obtained from the studied devices; therefore, these cannot be used interchangeably for critically ill septic shock patients on high doses of vasoactive substances.</p>","PeriodicalId":21279,"journal":{"name":"Romanian journal of anaesthesia and intensive care","volume":"24 2","pages":"89-100"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.21454/rjaic.7518.242.min","citationCount":"0","resultStr":"{\"title\":\"Assessment of method agreement between two minimally invasive hemodynamic measurements in septic shock patients on high doses of vasopressor drugs. A preliminary study.\",\"authors\":\"Oana Antal, Mihai Mărginean, Natalia Hagău\",\"doi\":\"10.21454/rjaic.7518.242.min\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Minimally invasive hemodynamic monitoring is still controversial among the methods used to assess the hemodynamic profile of the septic shock patient. The aim of this study was to test the level of agreement between two different devices.</p><p><strong>Methods: </strong>We collected 385 data entries during 12-hour intervals from four critically ill patients with septic shock and high doses of vasoactive therapy using two minimally invasive methods at the same time: Vigileo™ device which uses the pulse contour principle, and EV1000™ monitoring platform which uses the transpulmonary thermodilution principle. The studied parameters were Stroke Volume (SV), Cardiac Output (CO) and Mean Arterial Pressure (MAP). We tested the agreement by performing the visual examination of data patterns using graphs and studying the bias, limits of agreement and creating Bland-Altman plots. For assessing the systematic, proportional and random differences, we computed a Passing-Bablock regression with the CUSUM test for linearity.</p><p><strong>Results: </strong>The one sample t-Test for the differences between the two methods against the null value was statistically significant for the studied parameters (p < 0.0001). The Bland-Altman analysis found no agreement between the data obtained using the two techniques, with calculated error percent as high as 88.28% for SV, 82.02% for CO and 42.06% for MAP. The Passing-Bablock regression analysis tested positive for systematic differences, but this could not be accounted for.</p><p><strong>Conclusion: </strong>We found no agreement between data obtained from the studied devices; therefore, these cannot be used interchangeably for critically ill septic shock patients on high doses of vasoactive substances.</p>\",\"PeriodicalId\":21279,\"journal\":{\"name\":\"Romanian journal of anaesthesia and intensive care\",\"volume\":\"24 2\",\"pages\":\"89-100\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.21454/rjaic.7518.242.min\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Romanian journal of anaesthesia and intensive care\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21454/rjaic.7518.242.min\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Romanian journal of anaesthesia and intensive care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21454/rjaic.7518.242.min","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Assessment of method agreement between two minimally invasive hemodynamic measurements in septic shock patients on high doses of vasopressor drugs. A preliminary study.
Background: Minimally invasive hemodynamic monitoring is still controversial among the methods used to assess the hemodynamic profile of the septic shock patient. The aim of this study was to test the level of agreement between two different devices.
Methods: We collected 385 data entries during 12-hour intervals from four critically ill patients with septic shock and high doses of vasoactive therapy using two minimally invasive methods at the same time: Vigileo™ device which uses the pulse contour principle, and EV1000™ monitoring platform which uses the transpulmonary thermodilution principle. The studied parameters were Stroke Volume (SV), Cardiac Output (CO) and Mean Arterial Pressure (MAP). We tested the agreement by performing the visual examination of data patterns using graphs and studying the bias, limits of agreement and creating Bland-Altman plots. For assessing the systematic, proportional and random differences, we computed a Passing-Bablock regression with the CUSUM test for linearity.
Results: The one sample t-Test for the differences between the two methods against the null value was statistically significant for the studied parameters (p < 0.0001). The Bland-Altman analysis found no agreement between the data obtained using the two techniques, with calculated error percent as high as 88.28% for SV, 82.02% for CO and 42.06% for MAP. The Passing-Bablock regression analysis tested positive for systematic differences, but this could not be accounted for.
Conclusion: We found no agreement between data obtained from the studied devices; therefore, these cannot be used interchangeably for critically ill septic shock patients on high doses of vasoactive substances.
期刊介绍:
The Romanian Journal of Anaesthesia and Intensive Care is the official journal of the Romanian Society of Anaesthesia and Intensive Care and has been published continuously since 1994. It is intended mainly for anaesthesia and intensive care providers, but it is also aimed at specialists in emergency medical care and in pain research and management. The Journal is indexed in Scopus, Embase, PubMed Central as well as the databases of the Romanian Ministry of Education and Research (CNCSIS) B+ category. The Journal publishes two issues per year, the first one in April and the second one in October, and contains original articles, reviews, case reports, letters to the editor, book reviews and commentaries. The Journal is distributed free of charge to the members of the Romanian Society of Anaesthesia and Intensive Care.