低轮廓、自膨胀支架治疗颅内动脉瘤的安全性和有效性:初步和中期结果-系统回顾和荟萃分析

Q1 Medicine
Interventional Neurology Pub Date : 2017-10-01 Epub Date: 2017-04-26 DOI:10.1159/000471890
Su-Yeon Park, Jae-Sang Oh, Hyuk-Jin Oh, Seok-Mann Yoon, Hack-Gun Bae
{"title":"低轮廓、自膨胀支架治疗颅内动脉瘤的安全性和有效性:初步和中期结果-系统回顾和荟萃分析","authors":"Su-Yeon Park,&nbsp;Jae-Sang Oh,&nbsp;Hyuk-Jin Oh,&nbsp;Seok-Mann Yoon,&nbsp;Hack-Gun Bae","doi":"10.1159/000471890","DOIUrl":null,"url":null,"abstract":"<p><p>Low-profile stents seem to be associated with a higher incidence of thromboembolic events compared with preexisting stents. We conducted a systematic review of 11 eligible reports and a meta-analysis of 7 reports with respect to the clinical efficacy and safety of low-profile stents. There were 217 intracranial aneurysms reported; 22% were ruptured aneurysms. In all, 72% were treated using single stenting, 19% were treated using overlapping stenting, and 6% were treated using balloon angioplasty followed by stenting; 3% were used to assess the flow diverter effect in a dissecting aneurysm or were treated using unexpected subtotal coil packing. On immediate postprocedural angiographic results, Raymond class I and II obliteration was obtained in 87% of the aneurysms. On angiographic results at 3-6 months, Raymond class I and II obliteration or stability was obtained in 79% of the aneurysms, and Raymond class III obliteration was obtained in 3% of the aneurysms. The recurrence rate on follow-up of intracranial aneurysms was 6.5% (5.7% with LEO Baby and 1.3% with LVIS Jr). The periprocedural complication rate was 12.4%. Periprocedural thromboembolism occurred in 6.5% of the cases. The rate of in-stent stenosis on follow-up of intracranial aneurysms was 10%. In the midterm result, the recurrence rate with use of low-profile, self-expandable stents was relatively low compared to that with use of other self-expandable stents. In the meta-analysis comparing LEO Baby with LVIS Jr, the obliteration rate at 6 months was not significantly different, but the periprocedural complication rate was relatively low with LVIS Jr.</p>","PeriodicalId":46280,"journal":{"name":"Interventional Neurology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000471890","citationCount":"21","resultStr":"{\"title\":\"Safety and Efficacy of Low-Profile, Self-Expandable Stents for Treatment of Intracranial Aneurysms: Initial and Midterm Results - A Systematic Review and Meta-Analysis.\",\"authors\":\"Su-Yeon Park,&nbsp;Jae-Sang Oh,&nbsp;Hyuk-Jin Oh,&nbsp;Seok-Mann Yoon,&nbsp;Hack-Gun Bae\",\"doi\":\"10.1159/000471890\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Low-profile stents seem to be associated with a higher incidence of thromboembolic events compared with preexisting stents. We conducted a systematic review of 11 eligible reports and a meta-analysis of 7 reports with respect to the clinical efficacy and safety of low-profile stents. There were 217 intracranial aneurysms reported; 22% were ruptured aneurysms. In all, 72% were treated using single stenting, 19% were treated using overlapping stenting, and 6% were treated using balloon angioplasty followed by stenting; 3% were used to assess the flow diverter effect in a dissecting aneurysm or were treated using unexpected subtotal coil packing. On immediate postprocedural angiographic results, Raymond class I and II obliteration was obtained in 87% of the aneurysms. On angiographic results at 3-6 months, Raymond class I and II obliteration or stability was obtained in 79% of the aneurysms, and Raymond class III obliteration was obtained in 3% of the aneurysms. The recurrence rate on follow-up of intracranial aneurysms was 6.5% (5.7% with LEO Baby and 1.3% with LVIS Jr). The periprocedural complication rate was 12.4%. Periprocedural thromboembolism occurred in 6.5% of the cases. The rate of in-stent stenosis on follow-up of intracranial aneurysms was 10%. In the midterm result, the recurrence rate with use of low-profile, self-expandable stents was relatively low compared to that with use of other self-expandable stents. In the meta-analysis comparing LEO Baby with LVIS Jr, the obliteration rate at 6 months was not significantly different, but the periprocedural complication rate was relatively low with LVIS Jr.</p>\",\"PeriodicalId\":46280,\"journal\":{\"name\":\"Interventional Neurology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000471890\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Neurology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000471890\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2017/4/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neurology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000471890","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/4/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 21

摘要

与现有支架相比,低轮廓支架似乎与更高的血栓栓塞事件发生率相关。我们对11份符合条件的报告进行了系统回顾,并对7份关于低轮廓支架临床疗效和安全性的报告进行了荟萃分析。报告颅内动脉瘤217例;22%为动脉瘤破裂。总的来说,72%的患者使用单一支架,19%的患者使用重叠支架,6%的患者使用球囊血管成形术后再使用支架;3%用于评估夹层动脉瘤的分流效果,或采用意外的次全线圈填充治疗。术后立即血管造影结果显示,87%的动脉瘤获得了雷蒙德I级和II级闭塞。在3-6个月的血管造影结果中,79%的动脉瘤获得了Raymond I级和II级闭塞或稳定,3%的动脉瘤获得了Raymond III级闭塞。颅内动脉瘤随访复发率为6.5% (LEO Baby为5.7%,LVIS Jr为1.3%)。围手术期并发症发生率为12.4%。6.5%的病例发生围手术期血栓栓塞。颅内动脉瘤随访时支架内狭窄发生率为10%。在中期结果中,与使用其他自扩展支架相比,使用低轮廓自扩展支架的复发率相对较低。在meta分析中,LEO Baby与LVIS Jr比较,6个月时的闭塞率无显著差异,但LVIS Jr的围手术期并发症发生率相对较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Safety and Efficacy of Low-Profile, Self-Expandable Stents for Treatment of Intracranial Aneurysms: Initial and Midterm Results - A Systematic Review and Meta-Analysis.

Safety and Efficacy of Low-Profile, Self-Expandable Stents for Treatment of Intracranial Aneurysms: Initial and Midterm Results - A Systematic Review and Meta-Analysis.

Safety and Efficacy of Low-Profile, Self-Expandable Stents for Treatment of Intracranial Aneurysms: Initial and Midterm Results - A Systematic Review and Meta-Analysis.

Low-profile stents seem to be associated with a higher incidence of thromboembolic events compared with preexisting stents. We conducted a systematic review of 11 eligible reports and a meta-analysis of 7 reports with respect to the clinical efficacy and safety of low-profile stents. There were 217 intracranial aneurysms reported; 22% were ruptured aneurysms. In all, 72% were treated using single stenting, 19% were treated using overlapping stenting, and 6% were treated using balloon angioplasty followed by stenting; 3% were used to assess the flow diverter effect in a dissecting aneurysm or were treated using unexpected subtotal coil packing. On immediate postprocedural angiographic results, Raymond class I and II obliteration was obtained in 87% of the aneurysms. On angiographic results at 3-6 months, Raymond class I and II obliteration or stability was obtained in 79% of the aneurysms, and Raymond class III obliteration was obtained in 3% of the aneurysms. The recurrence rate on follow-up of intracranial aneurysms was 6.5% (5.7% with LEO Baby and 1.3% with LVIS Jr). The periprocedural complication rate was 12.4%. Periprocedural thromboembolism occurred in 6.5% of the cases. The rate of in-stent stenosis on follow-up of intracranial aneurysms was 10%. In the midterm result, the recurrence rate with use of low-profile, self-expandable stents was relatively low compared to that with use of other self-expandable stents. In the meta-analysis comparing LEO Baby with LVIS Jr, the obliteration rate at 6 months was not significantly different, but the periprocedural complication rate was relatively low with LVIS Jr.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Interventional Neurology
Interventional Neurology CLINICAL NEUROLOGY-
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信