{"title":"低轮廓、自膨胀支架治疗颅内动脉瘤的安全性和有效性:初步和中期结果-系统回顾和荟萃分析","authors":"Su-Yeon Park, Jae-Sang Oh, Hyuk-Jin Oh, Seok-Mann Yoon, Hack-Gun Bae","doi":"10.1159/000471890","DOIUrl":null,"url":null,"abstract":"<p><p>Low-profile stents seem to be associated with a higher incidence of thromboembolic events compared with preexisting stents. We conducted a systematic review of 11 eligible reports and a meta-analysis of 7 reports with respect to the clinical efficacy and safety of low-profile stents. There were 217 intracranial aneurysms reported; 22% were ruptured aneurysms. In all, 72% were treated using single stenting, 19% were treated using overlapping stenting, and 6% were treated using balloon angioplasty followed by stenting; 3% were used to assess the flow diverter effect in a dissecting aneurysm or were treated using unexpected subtotal coil packing. On immediate postprocedural angiographic results, Raymond class I and II obliteration was obtained in 87% of the aneurysms. On angiographic results at 3-6 months, Raymond class I and II obliteration or stability was obtained in 79% of the aneurysms, and Raymond class III obliteration was obtained in 3% of the aneurysms. The recurrence rate on follow-up of intracranial aneurysms was 6.5% (5.7% with LEO Baby and 1.3% with LVIS Jr). The periprocedural complication rate was 12.4%. Periprocedural thromboembolism occurred in 6.5% of the cases. The rate of in-stent stenosis on follow-up of intracranial aneurysms was 10%. In the midterm result, the recurrence rate with use of low-profile, self-expandable stents was relatively low compared to that with use of other self-expandable stents. In the meta-analysis comparing LEO Baby with LVIS Jr, the obliteration rate at 6 months was not significantly different, but the periprocedural complication rate was relatively low with LVIS Jr.</p>","PeriodicalId":46280,"journal":{"name":"Interventional Neurology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000471890","citationCount":"21","resultStr":"{\"title\":\"Safety and Efficacy of Low-Profile, Self-Expandable Stents for Treatment of Intracranial Aneurysms: Initial and Midterm Results - A Systematic Review and Meta-Analysis.\",\"authors\":\"Su-Yeon Park, Jae-Sang Oh, Hyuk-Jin Oh, Seok-Mann Yoon, Hack-Gun Bae\",\"doi\":\"10.1159/000471890\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Low-profile stents seem to be associated with a higher incidence of thromboembolic events compared with preexisting stents. We conducted a systematic review of 11 eligible reports and a meta-analysis of 7 reports with respect to the clinical efficacy and safety of low-profile stents. There were 217 intracranial aneurysms reported; 22% were ruptured aneurysms. In all, 72% were treated using single stenting, 19% were treated using overlapping stenting, and 6% were treated using balloon angioplasty followed by stenting; 3% were used to assess the flow diverter effect in a dissecting aneurysm or were treated using unexpected subtotal coil packing. On immediate postprocedural angiographic results, Raymond class I and II obliteration was obtained in 87% of the aneurysms. On angiographic results at 3-6 months, Raymond class I and II obliteration or stability was obtained in 79% of the aneurysms, and Raymond class III obliteration was obtained in 3% of the aneurysms. The recurrence rate on follow-up of intracranial aneurysms was 6.5% (5.7% with LEO Baby and 1.3% with LVIS Jr). The periprocedural complication rate was 12.4%. Periprocedural thromboembolism occurred in 6.5% of the cases. The rate of in-stent stenosis on follow-up of intracranial aneurysms was 10%. In the midterm result, the recurrence rate with use of low-profile, self-expandable stents was relatively low compared to that with use of other self-expandable stents. In the meta-analysis comparing LEO Baby with LVIS Jr, the obliteration rate at 6 months was not significantly different, but the periprocedural complication rate was relatively low with LVIS Jr.</p>\",\"PeriodicalId\":46280,\"journal\":{\"name\":\"Interventional Neurology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000471890\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Neurology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000471890\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2017/4/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neurology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000471890","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/4/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
Safety and Efficacy of Low-Profile, Self-Expandable Stents for Treatment of Intracranial Aneurysms: Initial and Midterm Results - A Systematic Review and Meta-Analysis.
Low-profile stents seem to be associated with a higher incidence of thromboembolic events compared with preexisting stents. We conducted a systematic review of 11 eligible reports and a meta-analysis of 7 reports with respect to the clinical efficacy and safety of low-profile stents. There were 217 intracranial aneurysms reported; 22% were ruptured aneurysms. In all, 72% were treated using single stenting, 19% were treated using overlapping stenting, and 6% were treated using balloon angioplasty followed by stenting; 3% were used to assess the flow diverter effect in a dissecting aneurysm or were treated using unexpected subtotal coil packing. On immediate postprocedural angiographic results, Raymond class I and II obliteration was obtained in 87% of the aneurysms. On angiographic results at 3-6 months, Raymond class I and II obliteration or stability was obtained in 79% of the aneurysms, and Raymond class III obliteration was obtained in 3% of the aneurysms. The recurrence rate on follow-up of intracranial aneurysms was 6.5% (5.7% with LEO Baby and 1.3% with LVIS Jr). The periprocedural complication rate was 12.4%. Periprocedural thromboembolism occurred in 6.5% of the cases. The rate of in-stent stenosis on follow-up of intracranial aneurysms was 10%. In the midterm result, the recurrence rate with use of low-profile, self-expandable stents was relatively low compared to that with use of other self-expandable stents. In the meta-analysis comparing LEO Baby with LVIS Jr, the obliteration rate at 6 months was not significantly different, but the periprocedural complication rate was relatively low with LVIS Jr.