{"title":"伪影模拟扭转:治疗病人而不是心电图。","authors":"Una Bergin, Richard M Lynch","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>ECG interpretation is an essential skill in the management of the acutely unwell patient and in addition to history taking and physical examination has been shown to have a significant effect on referral patterns to cardiologists. One of the basic initial steps in ECG interpretation is assessment for the presence of artefact which if present can dramatically influence the diagnosis. The most common sources of artefact are tremor e.g. in Parkinson’s disease, loose skin electrodes and electromagnetic interference from other medical devices and mobile phones. The Medicines and Healthcare products Regulatory Agency in the UK advises that mobile phones should be kept at least one metre away from equipment that is sensitive to electromagnetic interference. The possibility that artefact is the cause of the ECG appearance should always be considered if bizarre ECG changes are present particularly in an asymptomatic patient. The ECG should always be interpreted in the context of the patient’s condition. If artefact is thought to be the cause of the ECG appearance, then any contributory factors present should be corrected and the ECG should be repeated before invasive investigations are undertaken or treatment is administered.</p>","PeriodicalId":39516,"journal":{"name":"Practitioner","volume":"261 1801","pages":"23-6"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Artefact mimicking torsades: treat the patient not the ECG.\",\"authors\":\"Una Bergin, Richard M Lynch\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>ECG interpretation is an essential skill in the management of the acutely unwell patient and in addition to history taking and physical examination has been shown to have a significant effect on referral patterns to cardiologists. One of the basic initial steps in ECG interpretation is assessment for the presence of artefact which if present can dramatically influence the diagnosis. The most common sources of artefact are tremor e.g. in Parkinson’s disease, loose skin electrodes and electromagnetic interference from other medical devices and mobile phones. The Medicines and Healthcare products Regulatory Agency in the UK advises that mobile phones should be kept at least one metre away from equipment that is sensitive to electromagnetic interference. The possibility that artefact is the cause of the ECG appearance should always be considered if bizarre ECG changes are present particularly in an asymptomatic patient. The ECG should always be interpreted in the context of the patient’s condition. If artefact is thought to be the cause of the ECG appearance, then any contributory factors present should be corrected and the ECG should be repeated before invasive investigations are undertaken or treatment is administered.</p>\",\"PeriodicalId\":39516,\"journal\":{\"name\":\"Practitioner\",\"volume\":\"261 1801\",\"pages\":\"23-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Practitioner\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Practitioner","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Artefact mimicking torsades: treat the patient not the ECG.
ECG interpretation is an essential skill in the management of the acutely unwell patient and in addition to history taking and physical examination has been shown to have a significant effect on referral patterns to cardiologists. One of the basic initial steps in ECG interpretation is assessment for the presence of artefact which if present can dramatically influence the diagnosis. The most common sources of artefact are tremor e.g. in Parkinson’s disease, loose skin electrodes and electromagnetic interference from other medical devices and mobile phones. The Medicines and Healthcare products Regulatory Agency in the UK advises that mobile phones should be kept at least one metre away from equipment that is sensitive to electromagnetic interference. The possibility that artefact is the cause of the ECG appearance should always be considered if bizarre ECG changes are present particularly in an asymptomatic patient. The ECG should always be interpreted in the context of the patient’s condition. If artefact is thought to be the cause of the ECG appearance, then any contributory factors present should be corrected and the ECG should be repeated before invasive investigations are undertaken or treatment is administered.
期刊介绍:
The term "practitioner" of course has general application. It is used in a wide variety of professional contexts and industry and service sectors. The Practioner.Com portal is intended to support professionals in a growing number of these. Across a range of sub-sites, we offer a raft of useful information and data on the core topic(s) covered. These range from Legal Practioner (legal profession) through ITIL Practitioner (IT Infrastructure Library), Information Security Practitioner, Insolvency Practitioner (IP), General Practitioner and beyond.