凝血酶生成测定对止血系统的整体评价:观点和局限性

Rita Carolina Figueiredo Duarte , Cláudia Natália Ferreira , Danyelle Romana Alves Rios , Helton José dos Reis , Maria das Graças Carvalho
{"title":"凝血酶生成测定对止血系统的整体评价:观点和局限性","authors":"Rita Carolina Figueiredo Duarte ,&nbsp;Cláudia Natália Ferreira ,&nbsp;Danyelle Romana Alves Rios ,&nbsp;Helton José dos Reis ,&nbsp;Maria das Graças Carvalho","doi":"10.1016/j.bjhh.2017.03.009","DOIUrl":null,"url":null,"abstract":"<div><p>The existing techniques to evaluate hemostasis in clinical laboratories are not sensitive enough to detect hypercoagulable and mild hypocoagulable states. Under different experimental conditions, the thrombin generation test may meet these requirements. This technique evaluates the overall balance between procoagulant and anticoagulant forces and has provided new insights in our understanding of the coagulation cascade, as well as of the diagnosis of hypocoagulability and hypercoagulability conditions. Thrombin generated in the thrombin generation test can be quantified as platelet-rich or platelet-poor plasma using the calibrated automated thrombogram method, which monitors the cleavage of a fluorogenic substrate that is simultaneously compared to the known thrombin activity in a non-clotting plasma sample. The calibrated automated thrombogram method is an open system, in which different antibodies, proteins, enzymes and peptides can be introduced to answer specific questions regarding hemostatic processes. The thrombin generation test has great clinical potential, such as in monitoring patients taking anticoagulants and antiplatelet drugs, screening for genetic or acquired thrombotic disorders, and evaluating bleeding risk control in patients with hemophilia using bypass agents or replacement therapy. Different to conventional coagulation tests, the thrombin generation test can be used for an overall evaluation of hemostasis, the results of which can then be used to evaluate specific characteristics of hemostasis, such as prothrombin time, activated partial thromboplastin time, and levels of fibrinogen and other coagulation factors. The introduction of this method will contribute to a better understanding and evaluation of overall hemostatic processes; however, this method still requires standardization and clinical validation.</p></div>","PeriodicalId":21233,"journal":{"name":"Revista Brasileira de Hematologia e Hemoterapia","volume":"39 3","pages":"Pages 259-265"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.bjhh.2017.03.009","citationCount":"85","resultStr":"{\"title\":\"Thrombin generation assays for global evaluation of the hemostatic system: perspectives and limitations\",\"authors\":\"Rita Carolina Figueiredo Duarte ,&nbsp;Cláudia Natália Ferreira ,&nbsp;Danyelle Romana Alves Rios ,&nbsp;Helton José dos Reis ,&nbsp;Maria das Graças Carvalho\",\"doi\":\"10.1016/j.bjhh.2017.03.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The existing techniques to evaluate hemostasis in clinical laboratories are not sensitive enough to detect hypercoagulable and mild hypocoagulable states. Under different experimental conditions, the thrombin generation test may meet these requirements. This technique evaluates the overall balance between procoagulant and anticoagulant forces and has provided new insights in our understanding of the coagulation cascade, as well as of the diagnosis of hypocoagulability and hypercoagulability conditions. Thrombin generated in the thrombin generation test can be quantified as platelet-rich or platelet-poor plasma using the calibrated automated thrombogram method, which monitors the cleavage of a fluorogenic substrate that is simultaneously compared to the known thrombin activity in a non-clotting plasma sample. The calibrated automated thrombogram method is an open system, in which different antibodies, proteins, enzymes and peptides can be introduced to answer specific questions regarding hemostatic processes. The thrombin generation test has great clinical potential, such as in monitoring patients taking anticoagulants and antiplatelet drugs, screening for genetic or acquired thrombotic disorders, and evaluating bleeding risk control in patients with hemophilia using bypass agents or replacement therapy. Different to conventional coagulation tests, the thrombin generation test can be used for an overall evaluation of hemostasis, the results of which can then be used to evaluate specific characteristics of hemostasis, such as prothrombin time, activated partial thromboplastin time, and levels of fibrinogen and other coagulation factors. The introduction of this method will contribute to a better understanding and evaluation of overall hemostatic processes; however, this method still requires standardization and clinical validation.</p></div>\",\"PeriodicalId\":21233,\"journal\":{\"name\":\"Revista Brasileira de Hematologia e Hemoterapia\",\"volume\":\"39 3\",\"pages\":\"Pages 259-265\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.bjhh.2017.03.009\",\"citationCount\":\"85\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Brasileira de Hematologia e Hemoterapia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1516848417300506\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira de Hematologia e Hemoterapia","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1516848417300506","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 85

摘要

临床实验室现有的止血评估技术在检测高凝和轻度低凝状态方面不够灵敏。在不同的实验条件下,凝血酶生成试验可以满足这些要求。该技术评估促凝剂和抗凝剂力量之间的总体平衡,并为我们对凝血级联的理解以及低凝性和高凝性疾病的诊断提供了新的见解。在凝血酶生成测试中产生的凝血酶可以被量化为血小板丰富或血小板贫乏的血浆,使用校准的自动血栓成像方法,该方法监测荧光底物的裂解,同时与非凝血血浆样品中的已知凝血酶活性进行比较。校准的自动血栓图方法是一个开放的系统,其中不同的抗体,蛋白质,酶和肽可以被引入来回答关于止血过程的具体问题。凝血酶生成试验具有很大的临床潜力,如监测服用抗凝血和抗血小板药物的患者,筛查遗传性或获得性血栓性疾病,以及评估血友病患者使用旁路药物或替代治疗的出血风险控制。不同于传统的凝血试验,凝血酶生成试验可用于止血的整体评价,其结果可用于评估止血的具体特征,如凝血酶原时间,活化部分凝血活酶时间,纤维蛋白原水平和其他凝血因子。该方法的引入将有助于更好地理解和评估整体止血过程;然而,该方法仍需要标准化和临床验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Thrombin generation assays for global evaluation of the hemostatic system: perspectives and limitations

Thrombin generation assays for global evaluation of the hemostatic system: perspectives and limitations

Thrombin generation assays for global evaluation of the hemostatic system: perspectives and limitations

Thrombin generation assays for global evaluation of the hemostatic system: perspectives and limitations

The existing techniques to evaluate hemostasis in clinical laboratories are not sensitive enough to detect hypercoagulable and mild hypocoagulable states. Under different experimental conditions, the thrombin generation test may meet these requirements. This technique evaluates the overall balance between procoagulant and anticoagulant forces and has provided new insights in our understanding of the coagulation cascade, as well as of the diagnosis of hypocoagulability and hypercoagulability conditions. Thrombin generated in the thrombin generation test can be quantified as platelet-rich or platelet-poor plasma using the calibrated automated thrombogram method, which monitors the cleavage of a fluorogenic substrate that is simultaneously compared to the known thrombin activity in a non-clotting plasma sample. The calibrated automated thrombogram method is an open system, in which different antibodies, proteins, enzymes and peptides can be introduced to answer specific questions regarding hemostatic processes. The thrombin generation test has great clinical potential, such as in monitoring patients taking anticoagulants and antiplatelet drugs, screening for genetic or acquired thrombotic disorders, and evaluating bleeding risk control in patients with hemophilia using bypass agents or replacement therapy. Different to conventional coagulation tests, the thrombin generation test can be used for an overall evaluation of hemostasis, the results of which can then be used to evaluate specific characteristics of hemostasis, such as prothrombin time, activated partial thromboplastin time, and levels of fibrinogen and other coagulation factors. The introduction of this method will contribute to a better understanding and evaluation of overall hemostatic processes; however, this method still requires standardization and clinical validation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
21 weeks
期刊介绍: A Revista Brasileira de Hematologia e Hemoterapia é um periódico científico de propriedade da Associação Brasileira de Hematologia e Hemoterapia, publicada bimestralmente. A abreviatura de seu título é Rev. Bras. Hematol. Hemoter., que deve ser usada em bibliografias, notas de rodapé e em referências e legendas bibliográficas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信