{"title":"原发性开角型青光眼的视觉诱发电位。","authors":"Mukesh Kumar Jha, Dilip Thakur, Nirmala Limbu, Badri Prasad Badhu, Bishnu Hari Paudel","doi":"10.1155/2017/9540609","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Visual evoked potentials (VEPs) assess the integrity of the visual pathways from the optic nerve to the occipital cortex. Optic disc cupping and visual field loss have been associated with prolongation of latency of VEP in primary open angle glaucoma (POAG).</p><p><strong>Methods: </strong>Pattern reversal and flash VEP tests were done in consenting 20 primary open angle glaucoma eyes and 40 normal control eyes.</p><p><strong>Results: </strong>In POAG cases, the refractive error [3.51 ± 1.88 versus 1.88 ± 1.11, D, <i>p</i> = 0.001], cup-disc ratio in percent [66.00 ± 16.98 versus 28.50 ± 5.80, <i>p</i> = 0.001], intraocular pressure [19.55 ± 2.08 versus 11.65 ± 1.64, mmHg, <i>p</i> = 0.001], and automated visual field pattern standard deviation [4.13 ± 6.96 versus 1.64 ± 0.45, dB, <i>p</i> = 0.001] were significantly more than in control. The visual acuity [0.41 ± 0.29 versus 1.00 ± 0.00, <i>p</i> = 0.001], foveal visual sensitivity [25.92 ± 6.88 versus 33.48 ± 1.75, dB, <i>p</i> = 0.001], and automated visual field mean deviation [-9.63 ± 10.58 versus 0.07 ± 1.54, dB, <i>p</i> = 0.001] were significantly less in cases than in control. Among VEP variables, pattern reversal latency N145 [149.00 ± 15.75 versus 137.52 ± 15.20, ms, <i>p</i> = 0.011], flash amplitude N75 [2.18 ± .57 versus 1.47 ± .38, <i>μ</i>V, <i>p</i> = 0.001], and flash amplitude N145 [1.99 ± .39 versus 1.43 ± .38, <i>μ</i>V, <i>p</i> = 0.001] were increased in cases. The pattern reversal amplitude N75 [1.97 ± .35 versus 2.47 ± .58, <i>μ</i>V, <i>p</i> = 0.001], amplitude P100 [3.09 ± .46 versus 6.07 ± 1.44, <i>μ</i>V, <i>p</i> = 0.001], and amplitude N145 [2.21 ± .58 versus 4.45 ± 1.99, <i>μ</i>V, <i>p</i> = 0.001] were decreased in cases.</p><p><strong>Conclusions: </strong>POAG caused glaucomatous damage to optic pathway.</p>","PeriodicalId":16405,"journal":{"name":"Journal of Neurodegenerative Diseases","volume":"2017 ","pages":"9540609"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2017/9540609","citationCount":"16","resultStr":"{\"title\":\"Visual Evoked Potentials in Primary Open Angle Glaucoma.\",\"authors\":\"Mukesh Kumar Jha, Dilip Thakur, Nirmala Limbu, Badri Prasad Badhu, Bishnu Hari Paudel\",\"doi\":\"10.1155/2017/9540609\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and aims: </strong>Visual evoked potentials (VEPs) assess the integrity of the visual pathways from the optic nerve to the occipital cortex. Optic disc cupping and visual field loss have been associated with prolongation of latency of VEP in primary open angle glaucoma (POAG).</p><p><strong>Methods: </strong>Pattern reversal and flash VEP tests were done in consenting 20 primary open angle glaucoma eyes and 40 normal control eyes.</p><p><strong>Results: </strong>In POAG cases, the refractive error [3.51 ± 1.88 versus 1.88 ± 1.11, D, <i>p</i> = 0.001], cup-disc ratio in percent [66.00 ± 16.98 versus 28.50 ± 5.80, <i>p</i> = 0.001], intraocular pressure [19.55 ± 2.08 versus 11.65 ± 1.64, mmHg, <i>p</i> = 0.001], and automated visual field pattern standard deviation [4.13 ± 6.96 versus 1.64 ± 0.45, dB, <i>p</i> = 0.001] were significantly more than in control. The visual acuity [0.41 ± 0.29 versus 1.00 ± 0.00, <i>p</i> = 0.001], foveal visual sensitivity [25.92 ± 6.88 versus 33.48 ± 1.75, dB, <i>p</i> = 0.001], and automated visual field mean deviation [-9.63 ± 10.58 versus 0.07 ± 1.54, dB, <i>p</i> = 0.001] were significantly less in cases than in control. Among VEP variables, pattern reversal latency N145 [149.00 ± 15.75 versus 137.52 ± 15.20, ms, <i>p</i> = 0.011], flash amplitude N75 [2.18 ± .57 versus 1.47 ± .38, <i>μ</i>V, <i>p</i> = 0.001], and flash amplitude N145 [1.99 ± .39 versus 1.43 ± .38, <i>μ</i>V, <i>p</i> = 0.001] were increased in cases. The pattern reversal amplitude N75 [1.97 ± .35 versus 2.47 ± .58, <i>μ</i>V, <i>p</i> = 0.001], amplitude P100 [3.09 ± .46 versus 6.07 ± 1.44, <i>μ</i>V, <i>p</i> = 0.001], and amplitude N145 [2.21 ± .58 versus 4.45 ± 1.99, <i>μ</i>V, <i>p</i> = 0.001] were decreased in cases.</p><p><strong>Conclusions: </strong>POAG caused glaucomatous damage to optic pathway.</p>\",\"PeriodicalId\":16405,\"journal\":{\"name\":\"Journal of Neurodegenerative Diseases\",\"volume\":\"2017 \",\"pages\":\"9540609\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2017/9540609\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Neurodegenerative Diseases\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2017/9540609\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2017/7/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neurodegenerative Diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2017/9540609","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/7/20 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
摘要
背景和目的:视觉诱发电位(VEPs)评估从视神经到枕皮质的视觉通路的完整性。视盘拔罐和视野丧失与原发性开角型青光眼(POAG) VEP潜伏期延长有关。方法:对20只原发开角型青光眼和40只正常对照眼进行模式反转和闪光VEP试验。结果:POAG患者的屈光不正[3.51±1.88比1.88±1.11,D, p = 0.001]、杯盘比[66.00±16.98比28.50±5.80,p = 0.001]、眼压[19.55±2.08比11.65±1.64,mmHg, p = 0.001]、自动视野模式标准差[4.13±6.96比1.64±0.45,dB, p = 0.001]均显著高于对照组。视力[0.41±0.29比1.00±0.00,p = 0.001]、中央凹视敏度[25.92±6.88比33.48±1.75,dB, p = 0.001]、自动视野平均偏差[-9.63±10.58比0.07±1.54,dB, p = 0.001]均显著小于对照组。在VEP变量中,模式反转潜伏期N145(149.00±15.75 vs 137.52±15.20,ms, p = 0.011)、闪光幅度N75(2.18±0.57 vs 1.47±0.38,μV, p = 0.001)、闪光幅度N145(1.99±0.39 vs 1.43±0.38,μV, p = 0.001)增加。病例的模式反转幅度N75[1.97±0.35 vs 2.47±0.58,μV, p = 0.001]、幅度P100[3.09±0.46 vs 6.07±1.44,μV, p = 0.001]、幅度N145[2.21±0.58 vs 4.45±1.99,μV, p = 0.001]均降低。结论:POAG对视神经通路造成青光眼损害。
Visual Evoked Potentials in Primary Open Angle Glaucoma.
Background and aims: Visual evoked potentials (VEPs) assess the integrity of the visual pathways from the optic nerve to the occipital cortex. Optic disc cupping and visual field loss have been associated with prolongation of latency of VEP in primary open angle glaucoma (POAG).
Methods: Pattern reversal and flash VEP tests were done in consenting 20 primary open angle glaucoma eyes and 40 normal control eyes.
Results: In POAG cases, the refractive error [3.51 ± 1.88 versus 1.88 ± 1.11, D, p = 0.001], cup-disc ratio in percent [66.00 ± 16.98 versus 28.50 ± 5.80, p = 0.001], intraocular pressure [19.55 ± 2.08 versus 11.65 ± 1.64, mmHg, p = 0.001], and automated visual field pattern standard deviation [4.13 ± 6.96 versus 1.64 ± 0.45, dB, p = 0.001] were significantly more than in control. The visual acuity [0.41 ± 0.29 versus 1.00 ± 0.00, p = 0.001], foveal visual sensitivity [25.92 ± 6.88 versus 33.48 ± 1.75, dB, p = 0.001], and automated visual field mean deviation [-9.63 ± 10.58 versus 0.07 ± 1.54, dB, p = 0.001] were significantly less in cases than in control. Among VEP variables, pattern reversal latency N145 [149.00 ± 15.75 versus 137.52 ± 15.20, ms, p = 0.011], flash amplitude N75 [2.18 ± .57 versus 1.47 ± .38, μV, p = 0.001], and flash amplitude N145 [1.99 ± .39 versus 1.43 ± .38, μV, p = 0.001] were increased in cases. The pattern reversal amplitude N75 [1.97 ± .35 versus 2.47 ± .58, μV, p = 0.001], amplitude P100 [3.09 ± .46 versus 6.07 ± 1.44, μV, p = 0.001], and amplitude N145 [2.21 ± .58 versus 4.45 ± 1.99, μV, p = 0.001] were decreased in cases.
Conclusions: POAG caused glaucomatous damage to optic pathway.