1型糖尿病人工胰腺MPC中连续血糖监测反馈的移动水平状态估计。

Ravi Gondhalekar, Eyal Dassau, Francis J Doyle
{"title":"1型糖尿病人工胰腺MPC中连续血糖监测反馈的移动水平状态估计。","authors":"Ravi Gondhalekar,&nbsp;Eyal Dassau,&nbsp;Francis J Doyle","doi":"10.1109/CDC.2014.7039399","DOIUrl":null,"url":null,"abstract":"<p><p>An extension of a novel state estimation scheme is presented. The proposed method is developed for model predictive control (MPC) of an artificial pancreas for automatic insulin delivery to people with type 1 diabetes mellitus; specifically, glycemia control based on feedback by a continuous glucose monitor. The state estimation strategy is akin to moving-horizon estimation, but effectively exploits knowledge of sensor recalibrations, ameliorates the effects of delays between measurements and the controller call, and accommodates irregularly sampled output measurements. The method performs a function fit and a sampling action to synthesize a mock output trajectory for constructing the state. In this paper the structure of the fitted function prototype is divorced from the structure of the function that is sampled, facilitating the strategic elimination of prediction artifacts that are not observed in the actual plant. The proposed estimation strategy is demonstrated using clinical data collected by a Dexcom G4 Platinum continuous glucose monitor.</p>","PeriodicalId":74517,"journal":{"name":"Proceedings of the ... IEEE Conference on Decision & Control. IEEE Conference on Decision & Control","volume":"2014 ","pages":"310-315"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CDC.2014.7039399","citationCount":"12","resultStr":"{\"title\":\"Moving-horizon-like state estimation via continuous glucose monitor feedback in MPC of an artificial pancreas for type 1 diabetes.\",\"authors\":\"Ravi Gondhalekar,&nbsp;Eyal Dassau,&nbsp;Francis J Doyle\",\"doi\":\"10.1109/CDC.2014.7039399\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An extension of a novel state estimation scheme is presented. The proposed method is developed for model predictive control (MPC) of an artificial pancreas for automatic insulin delivery to people with type 1 diabetes mellitus; specifically, glycemia control based on feedback by a continuous glucose monitor. The state estimation strategy is akin to moving-horizon estimation, but effectively exploits knowledge of sensor recalibrations, ameliorates the effects of delays between measurements and the controller call, and accommodates irregularly sampled output measurements. The method performs a function fit and a sampling action to synthesize a mock output trajectory for constructing the state. In this paper the structure of the fitted function prototype is divorced from the structure of the function that is sampled, facilitating the strategic elimination of prediction artifacts that are not observed in the actual plant. The proposed estimation strategy is demonstrated using clinical data collected by a Dexcom G4 Platinum continuous glucose monitor.</p>\",\"PeriodicalId\":74517,\"journal\":{\"name\":\"Proceedings of the ... IEEE Conference on Decision & Control. IEEE Conference on Decision & Control\",\"volume\":\"2014 \",\"pages\":\"310-315\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/CDC.2014.7039399\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the ... IEEE Conference on Decision & Control. IEEE Conference on Decision & Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CDC.2014.7039399\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2015/2/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the ... IEEE Conference on Decision & Control. IEEE Conference on Decision & Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CDC.2014.7039399","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2015/2/12 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

提出了一种新的状态估计方法的推广。提出了一种用于1型糖尿病患者胰岛素自动输送人工胰腺模型预测控制(MPC)的方法;具体来说,是基于连续血糖监测仪反馈的血糖控制。状态估计策略类似于移动地平线估计,但有效地利用了传感器重新校准的知识,改善了测量和控制器调用之间延迟的影响,并适应不规则采样的输出测量。该方法通过函数拟合和采样动作来合成模拟输出轨迹,用于构造状态。在本文中,拟合函数原型的结构与被采样函数的结构分离,有助于战略性地消除在实际工厂中未观察到的预测伪影。采用Dexcom G4 Platinum连续血糖监测仪收集的临床数据验证了所提出的估计策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Moving-horizon-like state estimation via continuous glucose monitor feedback in MPC of an artificial pancreas for type 1 diabetes.

Moving-horizon-like state estimation via continuous glucose monitor feedback in MPC of an artificial pancreas for type 1 diabetes.

Moving-horizon-like state estimation via continuous glucose monitor feedback in MPC of an artificial pancreas for type 1 diabetes.

An extension of a novel state estimation scheme is presented. The proposed method is developed for model predictive control (MPC) of an artificial pancreas for automatic insulin delivery to people with type 1 diabetes mellitus; specifically, glycemia control based on feedback by a continuous glucose monitor. The state estimation strategy is akin to moving-horizon estimation, but effectively exploits knowledge of sensor recalibrations, ameliorates the effects of delays between measurements and the controller call, and accommodates irregularly sampled output measurements. The method performs a function fit and a sampling action to synthesize a mock output trajectory for constructing the state. In this paper the structure of the fitted function prototype is divorced from the structure of the function that is sampled, facilitating the strategic elimination of prediction artifacts that are not observed in the actual plant. The proposed estimation strategy is demonstrated using clinical data collected by a Dexcom G4 Platinum continuous glucose monitor.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信