系统性硬化症患者通气分布与小气道功能的关系

B.R.A. Silva , R. Rufino , C.H. Costa , V.S. Vilela , R.A. Levy , A.J. Lopes
{"title":"系统性硬化症患者通气分布与小气道功能的关系","authors":"B.R.A. Silva ,&nbsp;R. Rufino ,&nbsp;C.H. Costa ,&nbsp;V.S. Vilela ,&nbsp;R.A. Levy ,&nbsp;A.J. Lopes","doi":"10.1016/j.rppnen.2017.01.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Despite the importance of traditional pulmonary function tests (PFTs) in managing systemic sclerosis (SSc), many patients with pulmonary disease diagnosed by computed tomography (CT) present with normal PFTs.</p></div><div><h3>Objective</h3><p>To evaluate the efficacy of the nitrogen single-breath washout (N<sub>2</sub>SBW) test in diagnosing SSc and to correlate N<sub>2</sub>SBW parameters with the PFT indexes used in the follow-up of these patients, clinical data, and CT findings.</p></div><div><h3>Methods</h3><p>Cross-sectional study in which 52 consecutive SSc patients were subjected to spirometry, body plethysmography, analysis of the diffusing capacity for carbon monoxide (DLCO), analysis of respiratory muscle strength, N<sub>2</sub>SBW testing, and CT analysis.</p></div><div><h3>Results</h3><p>Twenty-eight patients had a forced vital capacity (FVC) that was &lt;70% of the predicted value. In the N<sub>2</sub>SBW test, 44 patients had a phase III slope (Phase III slope<sub>N2SBW</sub>) that was &gt;120% of the predicted value, while 15 patients had a closing volume/vital capacity (CV/VC) that was &gt;120% of the predicted value. A significant difference in Phase III slope<sub>N2SBW</sub> was observed when the patients with predominant traction bronchiectasis and honeycombing were compared to the patients with other CT patterns (<em>p</em> <!-->&lt;<!--> <!-->0.0001). The Phase III slope<sub>N2SBW</sub> was correlated with FVC (<em>r</em><sub>s</sub> <!-->=<!--> <!-->−0.845, <em>p</em> <!-->&lt;<!--> <!-->0.0001) and DLCO (<em>r</em><sub>s</sub> <!-->=<!--> <!-->−0.600, <em>p</em> <!-->&lt;<!--> <!-->0.0001), and the CV/VC was correlated with FVC (<em>r</em><sub>s</sub> <!-->=<!--> <!-->−0.460, <em>p</em> <!-->=<!--> <!-->0.0006) and residual volume/total lung capacity (<em>r</em><sub>s</sub> <!-->=<!--> <!-->0.328, <em>p</em> <!-->=<!--> <!-->0.017).</p></div><div><h3>Conclusion</h3><p>Ventilation heterogeneity is a frequent finding in SSc patients that is associated with restrictive damage, changes in pulmonary diffusion, and CT patterns. In addition, approximately one-third of the patients presented with findings that were compatible with small airway disease.</p></div>","PeriodicalId":101122,"journal":{"name":"Revista Portuguesa de Pneumologia (English Edition)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.rppnen.2017.01.004","citationCount":"11","resultStr":"{\"title\":\"Ventilation distribution and small airway function in patients with systemic sclerosis\",\"authors\":\"B.R.A. Silva ,&nbsp;R. Rufino ,&nbsp;C.H. Costa ,&nbsp;V.S. Vilela ,&nbsp;R.A. Levy ,&nbsp;A.J. Lopes\",\"doi\":\"10.1016/j.rppnen.2017.01.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Despite the importance of traditional pulmonary function tests (PFTs) in managing systemic sclerosis (SSc), many patients with pulmonary disease diagnosed by computed tomography (CT) present with normal PFTs.</p></div><div><h3>Objective</h3><p>To evaluate the efficacy of the nitrogen single-breath washout (N<sub>2</sub>SBW) test in diagnosing SSc and to correlate N<sub>2</sub>SBW parameters with the PFT indexes used in the follow-up of these patients, clinical data, and CT findings.</p></div><div><h3>Methods</h3><p>Cross-sectional study in which 52 consecutive SSc patients were subjected to spirometry, body plethysmography, analysis of the diffusing capacity for carbon monoxide (DLCO), analysis of respiratory muscle strength, N<sub>2</sub>SBW testing, and CT analysis.</p></div><div><h3>Results</h3><p>Twenty-eight patients had a forced vital capacity (FVC) that was &lt;70% of the predicted value. In the N<sub>2</sub>SBW test, 44 patients had a phase III slope (Phase III slope<sub>N2SBW</sub>) that was &gt;120% of the predicted value, while 15 patients had a closing volume/vital capacity (CV/VC) that was &gt;120% of the predicted value. A significant difference in Phase III slope<sub>N2SBW</sub> was observed when the patients with predominant traction bronchiectasis and honeycombing were compared to the patients with other CT patterns (<em>p</em> <!-->&lt;<!--> <!-->0.0001). The Phase III slope<sub>N2SBW</sub> was correlated with FVC (<em>r</em><sub>s</sub> <!-->=<!--> <!-->−0.845, <em>p</em> <!-->&lt;<!--> <!-->0.0001) and DLCO (<em>r</em><sub>s</sub> <!-->=<!--> <!-->−0.600, <em>p</em> <!-->&lt;<!--> <!-->0.0001), and the CV/VC was correlated with FVC (<em>r</em><sub>s</sub> <!-->=<!--> <!-->−0.460, <em>p</em> <!-->=<!--> <!-->0.0006) and residual volume/total lung capacity (<em>r</em><sub>s</sub> <!-->=<!--> <!-->0.328, <em>p</em> <!-->=<!--> <!-->0.017).</p></div><div><h3>Conclusion</h3><p>Ventilation heterogeneity is a frequent finding in SSc patients that is associated with restrictive damage, changes in pulmonary diffusion, and CT patterns. In addition, approximately one-third of the patients presented with findings that were compatible with small airway disease.</p></div>\",\"PeriodicalId\":101122,\"journal\":{\"name\":\"Revista Portuguesa de Pneumologia (English Edition)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.rppnen.2017.01.004\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Portuguesa de Pneumologia (English Edition)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2173511517300234\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Portuguesa de Pneumologia (English Edition)","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2173511517300234","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

尽管传统的肺功能检查(PFTs)在治疗系统性硬化症(SSc)中很重要,但许多通过计算机断层扫描(CT)诊断的肺部疾病患者的PFTs正常。目的评价氮单次呼吸冲洗试验(N2SBW)对SSc的诊断效果,并将N2SBW参数与患者随访时使用的PFT指标、临床资料及CT表现进行比较。方法对52例SSc患者进行横断面研究,对其进行肺活量测定、体体积谱、一氧化碳弥散能力(DLCO)分析、呼吸肌力量分析、N2SBW测试和CT分析。结果28例患者用力肺活量(FVC)为预测值的70%。在N2SBW试验中,44例患者的III期斜率(phase III slopeN2SBW)为预测值的120%,而15例患者的闭合容积/生命容量(CV/VC)为预测值的120%。以牵引支气管扩张和蜂窝状为主的患者与其他CT表现的患者相比,III期slopeN2SBW有显著差异(p <0.0001)。III期slopeN2SBW与FVC相关(rs = - 0.845, p <0.0001)和DLCO (rs = - 0.600, p <CV/VC与FVC (rs =−0.460,p = 0.0006)、残气量/总肺活量(rs = 0.328, p = 0.017)相关。结论通气异质性在SSc患者中很常见,与限制性损伤、肺弥散改变和CT表现相关。此外,大约三分之一的患者表现出与小气道疾病相符的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ventilation distribution and small airway function in patients with systemic sclerosis

Background

Despite the importance of traditional pulmonary function tests (PFTs) in managing systemic sclerosis (SSc), many patients with pulmonary disease diagnosed by computed tomography (CT) present with normal PFTs.

Objective

To evaluate the efficacy of the nitrogen single-breath washout (N2SBW) test in diagnosing SSc and to correlate N2SBW parameters with the PFT indexes used in the follow-up of these patients, clinical data, and CT findings.

Methods

Cross-sectional study in which 52 consecutive SSc patients were subjected to spirometry, body plethysmography, analysis of the diffusing capacity for carbon monoxide (DLCO), analysis of respiratory muscle strength, N2SBW testing, and CT analysis.

Results

Twenty-eight patients had a forced vital capacity (FVC) that was <70% of the predicted value. In the N2SBW test, 44 patients had a phase III slope (Phase III slopeN2SBW) that was >120% of the predicted value, while 15 patients had a closing volume/vital capacity (CV/VC) that was >120% of the predicted value. A significant difference in Phase III slopeN2SBW was observed when the patients with predominant traction bronchiectasis and honeycombing were compared to the patients with other CT patterns (p < 0.0001). The Phase III slopeN2SBW was correlated with FVC (rs = −0.845, p < 0.0001) and DLCO (rs = −0.600, p < 0.0001), and the CV/VC was correlated with FVC (rs = −0.460, p = 0.0006) and residual volume/total lung capacity (rs = 0.328, p = 0.017).

Conclusion

Ventilation heterogeneity is a frequent finding in SSc patients that is associated with restrictive damage, changes in pulmonary diffusion, and CT patterns. In addition, approximately one-third of the patients presented with findings that were compatible with small airway disease.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信