螺旋中轴线上原子模型及其低温电镜图像的比较。

Jing He, Stephanie Zeil, Hussam Hallak, Kele McKaig, Julio Kovacs, Willy Wriggers
{"title":"螺旋中轴线上原子模型及其低温电镜图像的比较。","authors":"Jing He,&nbsp;Stephanie Zeil,&nbsp;Hussam Hallak,&nbsp;Kele McKaig,&nbsp;Julio Kovacs,&nbsp;Willy Wriggers","doi":"10.1109/BIBM.2015.7359860","DOIUrl":null,"url":null,"abstract":"<p><p>Cryo-electron microscopy (cryo-EM) is an important biophysical technique that produces three-dimensional (3D) density maps at different resolutions. Because more and more models are being produced from cryo-EM density maps, validation of the models is becoming important. We propose a method for measuring local agreement between a model and the density map using the central axis of the helix. This method was tested using 19 helices from cryo-EM density maps between 5.5 Å and 7.2 Å resolution and 94 helices from simulated density maps. This method distinguished most of the well-fitting helices, although challenges exist for shorter helices.</p>","PeriodicalId":74563,"journal":{"name":"Proceedings. IEEE International Conference on Bioinformatics and Biomedicine","volume":"2015 ","pages":"1253-1259"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/BIBM.2015.7359860","citationCount":"1","resultStr":"{\"title\":\"Comparison of an Atomic Model and Its Cryo-EM Image at the Central Axis of a Helix.\",\"authors\":\"Jing He,&nbsp;Stephanie Zeil,&nbsp;Hussam Hallak,&nbsp;Kele McKaig,&nbsp;Julio Kovacs,&nbsp;Willy Wriggers\",\"doi\":\"10.1109/BIBM.2015.7359860\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Cryo-electron microscopy (cryo-EM) is an important biophysical technique that produces three-dimensional (3D) density maps at different resolutions. Because more and more models are being produced from cryo-EM density maps, validation of the models is becoming important. We propose a method for measuring local agreement between a model and the density map using the central axis of the helix. This method was tested using 19 helices from cryo-EM density maps between 5.5 Å and 7.2 Å resolution and 94 helices from simulated density maps. This method distinguished most of the well-fitting helices, although challenges exist for shorter helices.</p>\",\"PeriodicalId\":74563,\"journal\":{\"name\":\"Proceedings. IEEE International Conference on Bioinformatics and Biomedicine\",\"volume\":\"2015 \",\"pages\":\"1253-1259\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/BIBM.2015.7359860\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. IEEE International Conference on Bioinformatics and Biomedicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIBM.2015.7359860\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. IEEE International Conference on Bioinformatics and Biomedicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIBM.2015.7359860","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

低温电子显微镜(cryo-EM)是一种重要的生物物理技术,可以产生不同分辨率的三维(3D)密度图。由于越来越多的模型是由低温电镜密度图产生的,因此模型的验证变得越来越重要。我们提出了一种利用螺旋的中轴线测量模型和密度图之间局部一致性的方法。采用5.5 Å ~ 7.2 Å分辨率的低温电镜密度图中的19条螺旋和模拟密度图中的94条螺旋对该方法进行了测试。该方法区分了大多数拟合良好的螺旋,尽管对于较短的螺旋存在挑战。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparison of an Atomic Model and Its Cryo-EM Image at the Central Axis of a Helix.

Comparison of an Atomic Model and Its Cryo-EM Image at the Central Axis of a Helix.

Comparison of an Atomic Model and Its Cryo-EM Image at the Central Axis of a Helix.

Cryo-electron microscopy (cryo-EM) is an important biophysical technique that produces three-dimensional (3D) density maps at different resolutions. Because more and more models are being produced from cryo-EM density maps, validation of the models is becoming important. We propose a method for measuring local agreement between a model and the density map using the central axis of the helix. This method was tested using 19 helices from cryo-EM density maps between 5.5 Å and 7.2 Å resolution and 94 helices from simulated density maps. This method distinguished most of the well-fitting helices, although challenges exist for shorter helices.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信