{"title":"预测多发性硬化症患者行走时的摄氧量。","authors":"Stamatis Agiovlasitis,&nbsp;Brian M Sandroff,&nbsp;Robert W Motl","doi":"10.1682/JRRD.2014.12.0307","DOIUrl":null,"url":null,"abstract":"<p><p>People with multiple sclerosis (MS) have an increased rate of gross oxygen uptake (gross-VO2) during treadmill walking, and their gross-VO2 may further vary with walking impairment. This study attempted to develop an equation for predicting gross-VO2 from walking speed and an index of walking impairment in persons with MS and examine its accuracy. Gross-VO2 was measured with open-circuit spirometry in 43 persons with MS (47 +/- 9 yr; 38 women) during five treadmill walking trials, each lasting 6 min, at 2.0, 2.5, 3.0, 3.5, and 4.0 mph (0.89, 1.12, 1.34, 1.56, and 1.79 m/s). The 12-Item Multiple Sclerosis Walking Scale (MSWS-12) and the single-item Patient Determined Disease Steps scale (PDDS) provided indices of walking impairment. Multilevel modeling with random intercepts and slopes showed significant effects of speed and MSWS-12 on gross-VO2 (p </= 0.014; R(2) = 0.70). PDDS was not a significant predictor. Gross-VO2 estimated by the regression equation did not differ from actual gross-VO2 across speeds. Mean absolute prediction error across speeds was 9.1%. The Bland-Altman plot indicated zero mean difference between actual and predicted gross-VO2 with modest 95% confidence intervals. Therefore, speed and MSWS-12 score are jointly highly predictive of gross-VO2 during treadmill walking in persons with MS.</p>","PeriodicalId":50065,"journal":{"name":"Journal of Rehabilitation Research and Development","volume":"53 2","pages":"199-206"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1682/JRRD.2014.12.0307","citationCount":"8","resultStr":"{\"title\":\"Prediction of oxygen uptake during walking in ambulatory persons with multiple sclerosis.\",\"authors\":\"Stamatis Agiovlasitis,&nbsp;Brian M Sandroff,&nbsp;Robert W Motl\",\"doi\":\"10.1682/JRRD.2014.12.0307\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>People with multiple sclerosis (MS) have an increased rate of gross oxygen uptake (gross-VO2) during treadmill walking, and their gross-VO2 may further vary with walking impairment. This study attempted to develop an equation for predicting gross-VO2 from walking speed and an index of walking impairment in persons with MS and examine its accuracy. Gross-VO2 was measured with open-circuit spirometry in 43 persons with MS (47 +/- 9 yr; 38 women) during five treadmill walking trials, each lasting 6 min, at 2.0, 2.5, 3.0, 3.5, and 4.0 mph (0.89, 1.12, 1.34, 1.56, and 1.79 m/s). The 12-Item Multiple Sclerosis Walking Scale (MSWS-12) and the single-item Patient Determined Disease Steps scale (PDDS) provided indices of walking impairment. Multilevel modeling with random intercepts and slopes showed significant effects of speed and MSWS-12 on gross-VO2 (p </= 0.014; R(2) = 0.70). PDDS was not a significant predictor. Gross-VO2 estimated by the regression equation did not differ from actual gross-VO2 across speeds. Mean absolute prediction error across speeds was 9.1%. The Bland-Altman plot indicated zero mean difference between actual and predicted gross-VO2 with modest 95% confidence intervals. Therefore, speed and MSWS-12 score are jointly highly predictive of gross-VO2 during treadmill walking in persons with MS.</p>\",\"PeriodicalId\":50065,\"journal\":{\"name\":\"Journal of Rehabilitation Research and Development\",\"volume\":\"53 2\",\"pages\":\"199-206\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1682/JRRD.2014.12.0307\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Rehabilitation Research and Development\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1682/JRRD.2014.12.0307\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation Research and Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1682/JRRD.2014.12.0307","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 8

摘要

患有多发性硬化症(MS)的人在跑步机上行走时总摄氧量(总摄氧量)增加,并且他们的总摄氧量可能会随着行走障碍而进一步变化。本研究试图建立一个从步行速度和MS患者步行障碍指数预测总vo2的方程,并检验其准确性。用开路肺活量法测量43例MS患者的总摄氧量(47 +/- 9年;38名女性)进行了5次跑步机步行试验,每次持续6分钟,速度分别为2.0、2.5、3.0、3.5和4.0英里/小时(0.89、1.12、1.34、1.56和1.79米/秒)。12项多发性硬化症步行量表(MSWS-12)和单项患者确定疾病步数量表(PDDS)提供了步行障碍的指标。具有随机截距和斜率的多层模型显示,速度和MSWS-12对总vo2有显著影响(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Prediction of oxygen uptake during walking in ambulatory persons with multiple sclerosis.

People with multiple sclerosis (MS) have an increased rate of gross oxygen uptake (gross-VO2) during treadmill walking, and their gross-VO2 may further vary with walking impairment. This study attempted to develop an equation for predicting gross-VO2 from walking speed and an index of walking impairment in persons with MS and examine its accuracy. Gross-VO2 was measured with open-circuit spirometry in 43 persons with MS (47 +/- 9 yr; 38 women) during five treadmill walking trials, each lasting 6 min, at 2.0, 2.5, 3.0, 3.5, and 4.0 mph (0.89, 1.12, 1.34, 1.56, and 1.79 m/s). The 12-Item Multiple Sclerosis Walking Scale (MSWS-12) and the single-item Patient Determined Disease Steps scale (PDDS) provided indices of walking impairment. Multilevel modeling with random intercepts and slopes showed significant effects of speed and MSWS-12 on gross-VO2 (p

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.64
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信