{"title":"使用基于计算机断层扫描的方法验证无创设备测量旋转膝关节松弛度。","authors":"Simon Neumann,&nbsp;Stefan Maas,&nbsp;Danièle Waldmann,&nbsp;Pierre-Louis Ricci,&nbsp;Arno Zürbes,&nbsp;Pierre-Jean Arnoux,&nbsp;Frédéric Walter,&nbsp;Jens Kelm","doi":"10.1155/2015/705201","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study is to validate a noninvasive rotational knee laxity measuring device called \"Rotameter P2\" with an approach based on Computed Tomography (CT). This CT-approach using X-rays is hence invasive and can be regarded as a precise reference method that may also be applied to similar devices. An error due to imperfect femur fixation was observed but can be neglected for small torques. The most significant estimation error is due to the unavoidable soft tissues rotation and hence flexibility in the measurement chain. The error increases with the applied torque. The assessment showed that the rotational knee angle measured with the Rotameter is still overestimated because of thigh and femur displacement, soft tissues deformation, and measurement artefacts adding up to a maximum of 285% error at +15 Nm for the Internal Rotation of female volunteers. This may be questioned if such noninvasive devices for measuring the Tibia-Femoral Rotation (TFR) can help diagnosing knee pathologies and investigate ligament reconstructive surgery. </p>","PeriodicalId":14433,"journal":{"name":"International Scholarly Research Notices","volume":"2015 ","pages":"705201"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2015/705201","citationCount":"0","resultStr":"{\"title\":\"Use of a Computed Tomography Based Approach to Validate Noninvasive Devices to Measure Rotational Knee Laxity.\",\"authors\":\"Simon Neumann,&nbsp;Stefan Maas,&nbsp;Danièle Waldmann,&nbsp;Pierre-Louis Ricci,&nbsp;Arno Zürbes,&nbsp;Pierre-Jean Arnoux,&nbsp;Frédéric Walter,&nbsp;Jens Kelm\",\"doi\":\"10.1155/2015/705201\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study is to validate a noninvasive rotational knee laxity measuring device called \\\"Rotameter P2\\\" with an approach based on Computed Tomography (CT). This CT-approach using X-rays is hence invasive and can be regarded as a precise reference method that may also be applied to similar devices. An error due to imperfect femur fixation was observed but can be neglected for small torques. The most significant estimation error is due to the unavoidable soft tissues rotation and hence flexibility in the measurement chain. The error increases with the applied torque. The assessment showed that the rotational knee angle measured with the Rotameter is still overestimated because of thigh and femur displacement, soft tissues deformation, and measurement artefacts adding up to a maximum of 285% error at +15 Nm for the Internal Rotation of female volunteers. This may be questioned if such noninvasive devices for measuring the Tibia-Femoral Rotation (TFR) can help diagnosing knee pathologies and investigate ligament reconstructive surgery. </p>\",\"PeriodicalId\":14433,\"journal\":{\"name\":\"International Scholarly Research Notices\",\"volume\":\"2015 \",\"pages\":\"705201\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2015/705201\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Scholarly Research Notices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2015/705201\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2015/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Scholarly Research Notices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2015/705201","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2015/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是验证一种基于计算机断层扫描(CT)的无创旋转膝关节松弛测量装置“Rotameter P2”。因此,这种使用x射线的ct方法具有侵入性,可以被视为一种精确的参考方法,也可以应用于类似的设备。观察到由于股骨固定不完美造成的误差,但对于小扭矩可以忽略不计。最显著的估计误差是由于不可避免的软组织旋转和测量链的灵活性。误差随扭矩的增大而增大。评估表明,由于大腿和股骨移位、软组织变形和测量伪像,Rotameter测量的旋转膝关节角度仍然高估,在+15 Nm时,女性志愿者的内旋误差最大可达285%。这种测量胫骨-股骨旋转(TFR)的无创设备是否有助于诊断膝关节病变和研究韧带重建手术,这一点值得质疑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Use of a Computed Tomography Based Approach to Validate Noninvasive Devices to Measure Rotational Knee Laxity.

Use of a Computed Tomography Based Approach to Validate Noninvasive Devices to Measure Rotational Knee Laxity.

Use of a Computed Tomography Based Approach to Validate Noninvasive Devices to Measure Rotational Knee Laxity.

Use of a Computed Tomography Based Approach to Validate Noninvasive Devices to Measure Rotational Knee Laxity.

The purpose of this study is to validate a noninvasive rotational knee laxity measuring device called "Rotameter P2" with an approach based on Computed Tomography (CT). This CT-approach using X-rays is hence invasive and can be regarded as a precise reference method that may also be applied to similar devices. An error due to imperfect femur fixation was observed but can be neglected for small torques. The most significant estimation error is due to the unavoidable soft tissues rotation and hence flexibility in the measurement chain. The error increases with the applied torque. The assessment showed that the rotational knee angle measured with the Rotameter is still overestimated because of thigh and femur displacement, soft tissues deformation, and measurement artefacts adding up to a maximum of 285% error at +15 Nm for the Internal Rotation of female volunteers. This may be questioned if such noninvasive devices for measuring the Tibia-Femoral Rotation (TFR) can help diagnosing knee pathologies and investigate ligament reconstructive surgery.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信