{"title":"使用散装可流动材料和树脂复合材料修复的牙髓治疗牙齿的抗折性。","authors":"Almira Isufi, Gianluca Plotino, Nicola Maria Grande, Pietro Ioppolo, Luca Testarelli, Rossella Bedini, Dina Al-Sudani, Gianluca Gambarini","doi":"10.11138/ads/2016.7.1.004","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite.</p><p><strong>Methods: </strong>Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.5 mm layer of the occlusal surface that was restored with the same resin composite as Group B. The specimens were subjected to compressive force in a material static-testing machine until fracture occurred, the maximum fracture load of the specimens was measured (N) and the type of fracture was recorded as favorable or unfavorable. Data were statistically analyzed with one-way analysis of variance (ANOVA) and Bonferroni tests (P<0.05).</p><p><strong>Results: </strong>No statistically significant differences were found among groups (P<0.05). Fracture resistance of endodontically treated teeth restored with a traditional resin composite and with a bulk fill flowable composite (SDR) was similar in both maxillary and mandibular molars and showed no significant decrease in fracture resistance compared to intact specimens.</p><p><strong>Conclusions: </strong>No significant difference was observed in the mechanical fracture resistance of endodontically treated molars restored with traditional resin composite restorations compared to bulk fill flowable composite restorations.</p>","PeriodicalId":78041,"journal":{"name":"Annali di stomatologia","volume":"7 1-2","pages":"4-10"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4955920/pdf/4-10.pdf","citationCount":"0","resultStr":"{\"title\":\"Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite.\",\"authors\":\"Almira Isufi, Gianluca Plotino, Nicola Maria Grande, Pietro Ioppolo, Luca Testarelli, Rossella Bedini, Dina Al-Sudani, Gianluca Gambarini\",\"doi\":\"10.11138/ads/2016.7.1.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite.</p><p><strong>Methods: </strong>Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.5 mm layer of the occlusal surface that was restored with the same resin composite as Group B. The specimens were subjected to compressive force in a material static-testing machine until fracture occurred, the maximum fracture load of the specimens was measured (N) and the type of fracture was recorded as favorable or unfavorable. Data were statistically analyzed with one-way analysis of variance (ANOVA) and Bonferroni tests (P<0.05).</p><p><strong>Results: </strong>No statistically significant differences were found among groups (P<0.05). Fracture resistance of endodontically treated teeth restored with a traditional resin composite and with a bulk fill flowable composite (SDR) was similar in both maxillary and mandibular molars and showed no significant decrease in fracture resistance compared to intact specimens.</p><p><strong>Conclusions: </strong>No significant difference was observed in the mechanical fracture resistance of endodontically treated molars restored with traditional resin composite restorations compared to bulk fill flowable composite restorations.</p>\",\"PeriodicalId\":78041,\"journal\":{\"name\":\"Annali di stomatologia\",\"volume\":\"7 1-2\",\"pages\":\"4-10\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4955920/pdf/4-10.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annali di stomatologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11138/ads/2016.7.1.004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2016/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annali di stomatologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11138/ads/2016.7.1.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:确定并比较使用大量填充流动材料(SDR)和传统树脂复合材料修复的牙髓治疗牙的抗折性:根据相似的尺寸选择 30 颗上颌第一磨牙和 30 颗下颌第一磨牙。经过清洁、根管塑形和充填以及粘接程序后,每种牙齿类型的标本被分配到 3 个亚组(n=10):A 组:对照组,包括完整的牙齿;B 组:用传统树脂复合材料(EsthetX;Dentsply-Italy,意大利罗马)修复通路龋洞;C 组:用大量填充流动复合材料(SDR;Dentsply-Italy)修复通路龋洞,但咬合面 1.试样在材料静力试验机中承受压缩力直至断裂,测量试样的最大断裂载荷(N),并记录断裂类型为有利或不利。数据采用单因素方差分析(ANOVA)和 Bonferroni 检验(PResults:结果:各组间无明显统计学差异:用传统树脂复合树脂修复体修复的牙髓治疗磨牙与大量填充的可流动复合树脂修复体相比,在抗机械折断性方面没有观察到明显差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite.

Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite.

Aim: To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite.

Methods: Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.5 mm layer of the occlusal surface that was restored with the same resin composite as Group B. The specimens were subjected to compressive force in a material static-testing machine until fracture occurred, the maximum fracture load of the specimens was measured (N) and the type of fracture was recorded as favorable or unfavorable. Data were statistically analyzed with one-way analysis of variance (ANOVA) and Bonferroni tests (P<0.05).

Results: No statistically significant differences were found among groups (P<0.05). Fracture resistance of endodontically treated teeth restored with a traditional resin composite and with a bulk fill flowable composite (SDR) was similar in both maxillary and mandibular molars and showed no significant decrease in fracture resistance compared to intact specimens.

Conclusions: No significant difference was observed in the mechanical fracture resistance of endodontically treated molars restored with traditional resin composite restorations compared to bulk fill flowable composite restorations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信