{"title":"骨源性细胞体外机械负荷的临床前模型。","authors":"Robin Michael Delaine-Smith,&nbsp;Behzad Javaheri,&nbsp;Jennifer Helen Edwards,&nbsp;Marisol Vazquez,&nbsp;Robin Mark Howard Rumney","doi":"10.1038/bonekey.2015.97","DOIUrl":null,"url":null,"abstract":"<p><p>It is well established that bone responds to mechanical stimuli whereby physical forces are translated into chemical signals between cells, via mechanotransduction. It is difficult however to study the precise cellular and molecular responses using in vivo systems. In vitro loading models, which aim to replicate forces found within the bone microenvironment, make the underlying processes of mechanotransduction accessible to the researcher. Direct measurements in vivo and predictive modeling have been used to define these forces in normal physiological and pathological states. The types of mechanical stimuli present in the bone include vibration, fluid shear, substrate deformation and compressive loading, which can all be applied in vitro to monolayer and three-dimensional (3D) cultures. In monolayer, vibration can be readily applied to cultures via a low-magnitude, high-frequency loading rig. Fluid shear can be applied to cultures in multiwell plates via a simple rocking platform to engender gravitational fluid movement or via a pump to cells attached to a slide within a parallel-plate flow chamber, which may be micropatterned for use with osteocytes. Substrate strain can be applied via the vacuum-driven FlexCell system or via a four-point loading jig. 3D cultures better replicate the bone microenvironment and can also be subjected to the same forms of mechanical stimuli as monolayer, including vibration, fluid shear via perfusion flow, strain or compression. 3D cocultures that more closely replicate the bone microenvironment can be used to study the collective response of several cell types to loading. This technical review summarizes the methods for applying mechanical stimuli to bone cells in vitro. </p>","PeriodicalId":72441,"journal":{"name":"BoneKEy reports","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1038/bonekey.2015.97","citationCount":"35","resultStr":"{\"title\":\"Preclinical models for in vitro mechanical loading of bone-derived cells.\",\"authors\":\"Robin Michael Delaine-Smith,&nbsp;Behzad Javaheri,&nbsp;Jennifer Helen Edwards,&nbsp;Marisol Vazquez,&nbsp;Robin Mark Howard Rumney\",\"doi\":\"10.1038/bonekey.2015.97\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>It is well established that bone responds to mechanical stimuli whereby physical forces are translated into chemical signals between cells, via mechanotransduction. It is difficult however to study the precise cellular and molecular responses using in vivo systems. In vitro loading models, which aim to replicate forces found within the bone microenvironment, make the underlying processes of mechanotransduction accessible to the researcher. Direct measurements in vivo and predictive modeling have been used to define these forces in normal physiological and pathological states. The types of mechanical stimuli present in the bone include vibration, fluid shear, substrate deformation and compressive loading, which can all be applied in vitro to monolayer and three-dimensional (3D) cultures. In monolayer, vibration can be readily applied to cultures via a low-magnitude, high-frequency loading rig. Fluid shear can be applied to cultures in multiwell plates via a simple rocking platform to engender gravitational fluid movement or via a pump to cells attached to a slide within a parallel-plate flow chamber, which may be micropatterned for use with osteocytes. Substrate strain can be applied via the vacuum-driven FlexCell system or via a four-point loading jig. 3D cultures better replicate the bone microenvironment and can also be subjected to the same forms of mechanical stimuli as monolayer, including vibration, fluid shear via perfusion flow, strain or compression. 3D cocultures that more closely replicate the bone microenvironment can be used to study the collective response of several cell types to loading. This technical review summarizes the methods for applying mechanical stimuli to bone cells in vitro. </p>\",\"PeriodicalId\":72441,\"journal\":{\"name\":\"BoneKEy reports\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-08-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1038/bonekey.2015.97\",\"citationCount\":\"35\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BoneKEy reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1038/bonekey.2015.97\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2015/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BoneKEy reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1038/bonekey.2015.97","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2015/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 35

摘要

众所周知,骨对机械刺激有反应,即物理力通过机械转导在细胞之间转化为化学信号。然而,使用体内系统来研究精确的细胞和分子反应是困难的。体外加载模型旨在复制骨微环境中发现的力,使研究人员可以访问机械转导的潜在过程。在正常的生理和病理状态下,直接的体内测量和预测模型已经被用来定义这些力。骨中存在的机械刺激类型包括振动、流体剪切、基底变形和压缩载荷,这些都可以在体外应用于单层和三维(3D)培养。在单层中,振动可以很容易地通过低量级,高频加载装置应用于培养。流体剪切可以应用于多孔板中的培养,通过简单的摇晃平台产生重力流体运动,或通过泵连接到平行板流室内的载玻片上的细胞,这可能是用于骨细胞的微图案。基板应变可以通过真空驱动的FlexCell系统或通过四点加载夹具施加。3D培养更好地复制了骨微环境,也可以受到与单层相同形式的机械刺激,包括振动、通过灌注流产生的流体剪切、应变或压缩。3D共培养更接近地复制骨微环境,可用于研究几种细胞类型对负载的集体反应。本文综述了体外对骨细胞施加机械刺激的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Preclinical models for in vitro mechanical loading of bone-derived cells.

Preclinical models for in vitro mechanical loading of bone-derived cells.

Preclinical models for in vitro mechanical loading of bone-derived cells.

Preclinical models for in vitro mechanical loading of bone-derived cells.

It is well established that bone responds to mechanical stimuli whereby physical forces are translated into chemical signals between cells, via mechanotransduction. It is difficult however to study the precise cellular and molecular responses using in vivo systems. In vitro loading models, which aim to replicate forces found within the bone microenvironment, make the underlying processes of mechanotransduction accessible to the researcher. Direct measurements in vivo and predictive modeling have been used to define these forces in normal physiological and pathological states. The types of mechanical stimuli present in the bone include vibration, fluid shear, substrate deformation and compressive loading, which can all be applied in vitro to monolayer and three-dimensional (3D) cultures. In monolayer, vibration can be readily applied to cultures via a low-magnitude, high-frequency loading rig. Fluid shear can be applied to cultures in multiwell plates via a simple rocking platform to engender gravitational fluid movement or via a pump to cells attached to a slide within a parallel-plate flow chamber, which may be micropatterned for use with osteocytes. Substrate strain can be applied via the vacuum-driven FlexCell system or via a four-point loading jig. 3D cultures better replicate the bone microenvironment and can also be subjected to the same forms of mechanical stimuli as monolayer, including vibration, fluid shear via perfusion flow, strain or compression. 3D cocultures that more closely replicate the bone microenvironment can be used to study the collective response of several cell types to loading. This technical review summarizes the methods for applying mechanical stimuli to bone cells in vitro.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信