2012年玉树患者体检血液中多氯联苯特异性积累的研究

Takashi Miyawaki, Shusaku Hirakawa, Takashi Todaka, Hironori Hirakawa, Tsuguhide Hori, Junboku Kajiwara, Teruaki Hirata, Hiroshi Uchi, Masutaka Furue
{"title":"2012年玉树患者体检血液中多氯联苯特异性积累的研究","authors":"Takashi Miyawaki,&nbsp;Shusaku Hirakawa,&nbsp;Takashi Todaka,&nbsp;Hironori Hirakawa,&nbsp;Tsuguhide Hori,&nbsp;Junboku Kajiwara,&nbsp;Teruaki Hirata,&nbsp;Hiroshi Uchi,&nbsp;Masutaka Furue","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, we analyzed polychlorinated biphenyls (PCBs) in the blood of Yusho patients collected from medical check-ups, which were conducted in 2012. The results show that 65 PCB isomers, not including non-ortho PCBs, were detected in the blood samples, and the total concentration was 620 ng g(-1) lipid. This value was comparable to the concentration in blood samples collected in 2005, and indicated that PCB concentrations in Yusho patients remained unchanged from 2005 to 2012. Here, we focused on major and specific PCB isomers in the blood samples of Yusho patients and normal controls. Examples of the former include hexaCB-153, hexaCB-138, and heptaCB-180, which are detected in human blood, while the latter include hexaCB-156, hexaCB-157, and heptaCB-189, and are highly detected in the blood of Yusho patients. Additionally, we tried to determine why the specific isomers were highly accumulated in the blood of Yusho patients as compared to the normal controls. We therefore analyzed these isomers in the contaminated rice oil, and found that the concentrations of hexaCB-156, hexaCB-157, and heptaCB-189 were 1800, 450, and 190 ng g(-1), respectively. Notably, previous studies indicated that these isomers might not be easily metabolized in humans. Therefore, these findings demonstrated that these isomers were highly accumulated in the blood of Yusho patients.</p>","PeriodicalId":12665,"journal":{"name":"Fukuoka igaku zasshi = Hukuoka acta medica","volume":"106 5","pages":"160-8"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Study on Polychlorinated Biphenyls Specifically--Accumulated in Blood of Yusho Patients Collected from Medical Check-Ups in 2012.\",\"authors\":\"Takashi Miyawaki,&nbsp;Shusaku Hirakawa,&nbsp;Takashi Todaka,&nbsp;Hironori Hirakawa,&nbsp;Tsuguhide Hori,&nbsp;Junboku Kajiwara,&nbsp;Teruaki Hirata,&nbsp;Hiroshi Uchi,&nbsp;Masutaka Furue\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this study, we analyzed polychlorinated biphenyls (PCBs) in the blood of Yusho patients collected from medical check-ups, which were conducted in 2012. The results show that 65 PCB isomers, not including non-ortho PCBs, were detected in the blood samples, and the total concentration was 620 ng g(-1) lipid. This value was comparable to the concentration in blood samples collected in 2005, and indicated that PCB concentrations in Yusho patients remained unchanged from 2005 to 2012. Here, we focused on major and specific PCB isomers in the blood samples of Yusho patients and normal controls. Examples of the former include hexaCB-153, hexaCB-138, and heptaCB-180, which are detected in human blood, while the latter include hexaCB-156, hexaCB-157, and heptaCB-189, and are highly detected in the blood of Yusho patients. Additionally, we tried to determine why the specific isomers were highly accumulated in the blood of Yusho patients as compared to the normal controls. We therefore analyzed these isomers in the contaminated rice oil, and found that the concentrations of hexaCB-156, hexaCB-157, and heptaCB-189 were 1800, 450, and 190 ng g(-1), respectively. Notably, previous studies indicated that these isomers might not be easily metabolized in humans. Therefore, these findings demonstrated that these isomers were highly accumulated in the blood of Yusho patients.</p>\",\"PeriodicalId\":12665,\"journal\":{\"name\":\"Fukuoka igaku zasshi = Hukuoka acta medica\",\"volume\":\"106 5\",\"pages\":\"160-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fukuoka igaku zasshi = Hukuoka acta medica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fukuoka igaku zasshi = Hukuoka acta medica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在本研究中,我们分析了2012年进行体检的玉树患者血液中的多氯联苯(PCBs)。结果表明,血样中检出65种多氯联苯异构体,总浓度为620 ng g(-1)脂质。该值与2005年采集的血液样本中的浓度相当,表明2005年至2012年玉树患者的多氯联苯浓度保持不变。在这里,我们重点研究了玉树患者和正常人血液样本中的主要和特定的多氯联苯异构体。前者包括hexaCB-153、hexaCB-138和heptaCB-180,在人类血液中检测到,后者包括hexaCB-156、hexaCB-157和heptaCB-189,在禹州患者血液中检测到的量很高。此外,我们试图确定为什么与正常对照相比,特定的异构体在玉树患者的血液中高度积累。因此,我们在污染的米油中分析了这些异构体,发现hexaCB-156、hexaCB-157和heptaCB-189的浓度分别为1800、450和190 ng g(-1)。值得注意的是,先前的研究表明,这些异构体可能不容易在人体内代谢。因此,这些发现表明这些异构体在玉树患者的血液中高度积累。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Study on Polychlorinated Biphenyls Specifically--Accumulated in Blood of Yusho Patients Collected from Medical Check-Ups in 2012.

In this study, we analyzed polychlorinated biphenyls (PCBs) in the blood of Yusho patients collected from medical check-ups, which were conducted in 2012. The results show that 65 PCB isomers, not including non-ortho PCBs, were detected in the blood samples, and the total concentration was 620 ng g(-1) lipid. This value was comparable to the concentration in blood samples collected in 2005, and indicated that PCB concentrations in Yusho patients remained unchanged from 2005 to 2012. Here, we focused on major and specific PCB isomers in the blood samples of Yusho patients and normal controls. Examples of the former include hexaCB-153, hexaCB-138, and heptaCB-180, which are detected in human blood, while the latter include hexaCB-156, hexaCB-157, and heptaCB-189, and are highly detected in the blood of Yusho patients. Additionally, we tried to determine why the specific isomers were highly accumulated in the blood of Yusho patients as compared to the normal controls. We therefore analyzed these isomers in the contaminated rice oil, and found that the concentrations of hexaCB-156, hexaCB-157, and heptaCB-189 were 1800, 450, and 190 ng g(-1), respectively. Notably, previous studies indicated that these isomers might not be easily metabolized in humans. Therefore, these findings demonstrated that these isomers were highly accumulated in the blood of Yusho patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信