薄片荧光显微镜(LSFM)

Q1 Health Professions
Michael W. Adams, Andrew F. Loftus, Sarah E. Dunn, Matthew S. Joens, James A.J. Fitzpatrick
{"title":"薄片荧光显微镜(LSFM)","authors":"Michael W. Adams,&nbsp;Andrew F. Loftus,&nbsp;Sarah E. Dunn,&nbsp;Matthew S. Joens,&nbsp;James A.J. Fitzpatrick","doi":"10.1002/0471142956.cy1237s71","DOIUrl":null,"url":null,"abstract":"<p>The development of confocal microscopy techniques introduced the ability to optically section fluorescent samples in the axial dimension, perpendicular to the image plane. These approaches, via the placement of a pinhole in the conjugate image plane, provided superior resolution in the axial (z) dimension resulting in nearly isotropic optical sections. However, increased axial resolution, via pinhole optics, comes at the cost of both speed and excitation efficiency. Light sheet fluorescent microscopy (LSFM), a century-old idea made possible with modern developments in both excitation and detection optics, provides sub-cellular resolution and optical sectioning capabilities without compromising speed or excitation efficiency. Over the past decade, several variations of LSFM have been implemented each with its own benefits and deficiencies. Here we discuss LSFM fundamentals and outline the basic principles of several major light-sheet-based imaging modalities (SPIM, inverted SPIM, multi-view SPIM, Bessel beam SPIM, and stimulated emission depletion SPIM) while considering their biological relevance in terms of intrusiveness, temporal resolution, and sample requirements. © 2015 by John Wiley &amp; Sons, Inc.</p>","PeriodicalId":11020,"journal":{"name":"Current Protocols in Cytometry","volume":"71 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2015-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/0471142956.cy1237s71","citationCount":"21","resultStr":"{\"title\":\"Light Sheet Fluorescence Microscopy (LSFM)\",\"authors\":\"Michael W. Adams,&nbsp;Andrew F. Loftus,&nbsp;Sarah E. Dunn,&nbsp;Matthew S. Joens,&nbsp;James A.J. Fitzpatrick\",\"doi\":\"10.1002/0471142956.cy1237s71\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The development of confocal microscopy techniques introduced the ability to optically section fluorescent samples in the axial dimension, perpendicular to the image plane. These approaches, via the placement of a pinhole in the conjugate image plane, provided superior resolution in the axial (z) dimension resulting in nearly isotropic optical sections. However, increased axial resolution, via pinhole optics, comes at the cost of both speed and excitation efficiency. Light sheet fluorescent microscopy (LSFM), a century-old idea made possible with modern developments in both excitation and detection optics, provides sub-cellular resolution and optical sectioning capabilities without compromising speed or excitation efficiency. Over the past decade, several variations of LSFM have been implemented each with its own benefits and deficiencies. Here we discuss LSFM fundamentals and outline the basic principles of several major light-sheet-based imaging modalities (SPIM, inverted SPIM, multi-view SPIM, Bessel beam SPIM, and stimulated emission depletion SPIM) while considering their biological relevance in terms of intrusiveness, temporal resolution, and sample requirements. © 2015 by John Wiley &amp; Sons, Inc.</p>\",\"PeriodicalId\":11020,\"journal\":{\"name\":\"Current Protocols in Cytometry\",\"volume\":\"71 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-01-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/0471142956.cy1237s71\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Protocols in Cytometry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/0471142956.cy1237s71\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Protocols in Cytometry","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/0471142956.cy1237s71","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 21

摘要

共聚焦显微镜技术的发展引入了在垂直于成像平面的轴向尺寸上对荧光样品进行光学切片的能力。这些方法通过在共轭成像平面上放置针孔,在轴向(z)尺寸上提供了优越的分辨率,从而产生了几乎各向同性的光学切片。然而,通过针孔光学增加轴向分辨率,是以速度和激发效率为代价的。光片荧光显微镜(LSFM)是一个有着百年历史的想法,随着激发和检测光学的现代发展,它提供了亚细胞分辨率和光学切片能力,而不会影响速度或激发效率。在过去的十年中,已经实现了LSFM的几种变体,每种变体都有自己的优点和不足。在这里,我们讨论了LSFM的基本原理,并概述了几种主要的基于光片的成像模式(SPIM,倒置SPIM,多视图SPIM,贝塞尔光束SPIM和受激发射耗尽SPIM)的基本原理,同时考虑了它们在侵入性,时间分辨率和样品要求方面的生物学相关性。©2015 by John Wiley &儿子,Inc。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Light Sheet Fluorescence Microscopy (LSFM)

Light Sheet Fluorescence Microscopy (LSFM)

Light Sheet Fluorescence Microscopy (LSFM)

Light Sheet Fluorescence Microscopy (LSFM)

The development of confocal microscopy techniques introduced the ability to optically section fluorescent samples in the axial dimension, perpendicular to the image plane. These approaches, via the placement of a pinhole in the conjugate image plane, provided superior resolution in the axial (z) dimension resulting in nearly isotropic optical sections. However, increased axial resolution, via pinhole optics, comes at the cost of both speed and excitation efficiency. Light sheet fluorescent microscopy (LSFM), a century-old idea made possible with modern developments in both excitation and detection optics, provides sub-cellular resolution and optical sectioning capabilities without compromising speed or excitation efficiency. Over the past decade, several variations of LSFM have been implemented each with its own benefits and deficiencies. Here we discuss LSFM fundamentals and outline the basic principles of several major light-sheet-based imaging modalities (SPIM, inverted SPIM, multi-view SPIM, Bessel beam SPIM, and stimulated emission depletion SPIM) while considering their biological relevance in terms of intrusiveness, temporal resolution, and sample requirements. © 2015 by John Wiley & Sons, Inc.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Protocols in Cytometry
Current Protocols in Cytometry Health Professions-Medical Laboratory Technology
自引率
0.00%
发文量
0
期刊介绍: Published in affiliation with the International Society for Advancement of Cytometry, Current Protocols in Cytometry is a "best practices" collection that distills and organizes the absolute latest techniques from the top cytometry labs and specialists worldwide. It is the most complete set of peer-reviewed protocols for flow and image cytometry available.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信