Basavegowdanadoddi Marinaik Chandranaik, Doddamane Rathnamma, S S Patil, Ramesh C Kovi, Jyotsana Dhawan, Shakunigowda Ranganatha, Shrikrishna Isloor, C Renukaprasad, K Prabhudas
{"title":"开发基于探针的实时 PCR 检测法,用于检测精液和其他临床样本中的牛疱疹病毒-1。","authors":"Basavegowdanadoddi Marinaik Chandranaik, Doddamane Rathnamma, S S Patil, Ramesh C Kovi, Jyotsana Dhawan, Shakunigowda Ranganatha, Shrikrishna Isloor, C Renukaprasad, K Prabhudas","doi":"10.1007/s13337-012-0112-1","DOIUrl":null,"url":null,"abstract":"<p><p>This study describes development of a TaqMan probe based real time PCR assay that can detect BoHV-1 of as low as 0.001 TCID50/0.1 ml in clinical samples, its comparative evaluation with indirect ELISA and virus isolation for detection of Bovine herpes virus-1 (BoHV-1) in semen and swab clinical samples. For this study, we collected samples from 212 animals (cattle and buffaloes) comprising 91 bulls and 121 females. Avidin-biotin ELISA employed on serum samples from 212 animals revealed 74 as seropositive for BoHV-1. On inoculation of semen/swabs on MDBK cell line, nine samples yielded cytopathic changes characteristic of herpes viruses. The isolates were confirmed by VNT and a conventional PCR. A real time PCR assay was standardised by designing a new set of TaqMan probe and primers targeting a 71 bp region on gB gene of the virus. The assay detected viral antigen in 21 seropositive and 14 seronegative animals, emphasizing the relevance of serology in BoHV-1 diagnosis, particularly in breeding stations. Further, real time PCR assay was 100 % sensitive and 87.19 % specific compared to virus isolation in detection of the BoHV-1 in clinical samples. The assay was validated at reputed national laboratories, with a sensitivity of ≥99 %. </p>","PeriodicalId":50370,"journal":{"name":"Indian Journal of Virology","volume":"24 1","pages":"16-26"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3650191/pdf/13337_2012_Article_112.pdf","citationCount":"0","resultStr":"{\"title\":\"Development of a probe based real time PCR assay for detection of bovine herpes virus-1 in semen and other clinical samples.\",\"authors\":\"Basavegowdanadoddi Marinaik Chandranaik, Doddamane Rathnamma, S S Patil, Ramesh C Kovi, Jyotsana Dhawan, Shakunigowda Ranganatha, Shrikrishna Isloor, C Renukaprasad, K Prabhudas\",\"doi\":\"10.1007/s13337-012-0112-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study describes development of a TaqMan probe based real time PCR assay that can detect BoHV-1 of as low as 0.001 TCID50/0.1 ml in clinical samples, its comparative evaluation with indirect ELISA and virus isolation for detection of Bovine herpes virus-1 (BoHV-1) in semen and swab clinical samples. For this study, we collected samples from 212 animals (cattle and buffaloes) comprising 91 bulls and 121 females. Avidin-biotin ELISA employed on serum samples from 212 animals revealed 74 as seropositive for BoHV-1. On inoculation of semen/swabs on MDBK cell line, nine samples yielded cytopathic changes characteristic of herpes viruses. The isolates were confirmed by VNT and a conventional PCR. A real time PCR assay was standardised by designing a new set of TaqMan probe and primers targeting a 71 bp region on gB gene of the virus. The assay detected viral antigen in 21 seropositive and 14 seronegative animals, emphasizing the relevance of serology in BoHV-1 diagnosis, particularly in breeding stations. Further, real time PCR assay was 100 % sensitive and 87.19 % specific compared to virus isolation in detection of the BoHV-1 in clinical samples. The assay was validated at reputed national laboratories, with a sensitivity of ≥99 %. </p>\",\"PeriodicalId\":50370,\"journal\":{\"name\":\"Indian Journal of Virology\",\"volume\":\"24 1\",\"pages\":\"16-26\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3650191/pdf/13337_2012_Article_112.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Virology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s13337-012-0112-1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/12/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Virology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s13337-012-0112-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/12/16 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
Development of a probe based real time PCR assay for detection of bovine herpes virus-1 in semen and other clinical samples.
This study describes development of a TaqMan probe based real time PCR assay that can detect BoHV-1 of as low as 0.001 TCID50/0.1 ml in clinical samples, its comparative evaluation with indirect ELISA and virus isolation for detection of Bovine herpes virus-1 (BoHV-1) in semen and swab clinical samples. For this study, we collected samples from 212 animals (cattle and buffaloes) comprising 91 bulls and 121 females. Avidin-biotin ELISA employed on serum samples from 212 animals revealed 74 as seropositive for BoHV-1. On inoculation of semen/swabs on MDBK cell line, nine samples yielded cytopathic changes characteristic of herpes viruses. The isolates were confirmed by VNT and a conventional PCR. A real time PCR assay was standardised by designing a new set of TaqMan probe and primers targeting a 71 bp region on gB gene of the virus. The assay detected viral antigen in 21 seropositive and 14 seronegative animals, emphasizing the relevance of serology in BoHV-1 diagnosis, particularly in breeding stations. Further, real time PCR assay was 100 % sensitive and 87.19 % specific compared to virus isolation in detection of the BoHV-1 in clinical samples. The assay was validated at reputed national laboratories, with a sensitivity of ≥99 %.