竞争性酶联免疫吸附试验的适应性,用于检测用于野生水禽的马血清中甲型流感病毒抗体。

Indian Journal of Virology Pub Date : 2012-12-01 Epub Date: 2012-08-02 DOI:10.1007/s13337-012-0074-3
M A Hoque, L F Skerratt, S Garland, G W Burgess, P Selleck
{"title":"竞争性酶联免疫吸附试验的适应性,用于检测用于野生水禽的马血清中甲型流感病毒抗体。","authors":"M A Hoque,&nbsp;L F Skerratt,&nbsp;S Garland,&nbsp;G W Burgess,&nbsp;P Selleck","doi":"10.1007/s13337-012-0074-3","DOIUrl":null,"url":null,"abstract":"<p><p>We applied a competitive enzyme-linked immunosorbent assay for the detection of antibodies for influenza A in equine sera to their detection in sera from wild aquatic birds. Suboptimal results were obtained for the optical density (OD) of the monoclonal antibody (MAb) control and reproducibility between duplicate analyses in the initial assessment. It was therefore necessary to modify the assay to deliver increased reliability and reproducibility while maintaining adequate sensitivity. We optimized reagent concentrations to obtain optimal OD values (close to 2) for the monoclonal antibody control and used 2, 2'-Azino-bis: 3-Benzthiazoline-6-Sulphonic Acid as an alternative chromogen to potentially reduce variability in duplicate analyses. The original assay was compared with the optimized versions, with and without post coating, for the detection of avian influenza viral antibodies in 240 sera obtained from wild plumed whistling ducks. A separate analytical sensitivity study on diluted positive field sera of plumed whistling ducks and a test of antigen stability after post coating were also performed. Some quantitative differences were detected between the original and modified assays. The original assay recorded higher percentage inhibition results which were potentially indicative of increased sensitivity. However, when reagent concentrations were increased in the original assay to the same levels as used in the modified versions, there were no quantitative differences for practical purposes. The original assay produced a median (OD) value of 0.81 for the (MAb) controls that is at the limit of acceptability. By contrast, the modified assays always produced acceptable optical density values for MAb controls. Our overall results indicated the modified assays were potentially more reliable (OD values close to 2), and of adequate sensitivity compared to the original assay in the detection of avian influenza viral antibodies in wild bird sera. Although further optimization of antigen and MAb concentrations should also be considered to increase the sensitivity of a modified assay, while maintaining acceptable optical density values for the MAb control. Post coating had a minimal quantitative effect on the results and stabilized the plates for 214 days. We therefore recommend the incorporation of post coating. </p>","PeriodicalId":50370,"journal":{"name":"Indian Journal of Virology","volume":"23 3","pages":"261-9"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s13337-012-0074-3","citationCount":"7","resultStr":"{\"title\":\"Adaptations of a competitive enzyme-linked immunosorbent assays for the detection of antibodies to influenza a virus in horse sera for use in wild aquatic birds.\",\"authors\":\"M A Hoque,&nbsp;L F Skerratt,&nbsp;S Garland,&nbsp;G W Burgess,&nbsp;P Selleck\",\"doi\":\"10.1007/s13337-012-0074-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We applied a competitive enzyme-linked immunosorbent assay for the detection of antibodies for influenza A in equine sera to their detection in sera from wild aquatic birds. Suboptimal results were obtained for the optical density (OD) of the monoclonal antibody (MAb) control and reproducibility between duplicate analyses in the initial assessment. It was therefore necessary to modify the assay to deliver increased reliability and reproducibility while maintaining adequate sensitivity. We optimized reagent concentrations to obtain optimal OD values (close to 2) for the monoclonal antibody control and used 2, 2'-Azino-bis: 3-Benzthiazoline-6-Sulphonic Acid as an alternative chromogen to potentially reduce variability in duplicate analyses. The original assay was compared with the optimized versions, with and without post coating, for the detection of avian influenza viral antibodies in 240 sera obtained from wild plumed whistling ducks. A separate analytical sensitivity study on diluted positive field sera of plumed whistling ducks and a test of antigen stability after post coating were also performed. Some quantitative differences were detected between the original and modified assays. The original assay recorded higher percentage inhibition results which were potentially indicative of increased sensitivity. However, when reagent concentrations were increased in the original assay to the same levels as used in the modified versions, there were no quantitative differences for practical purposes. The original assay produced a median (OD) value of 0.81 for the (MAb) controls that is at the limit of acceptability. By contrast, the modified assays always produced acceptable optical density values for MAb controls. Our overall results indicated the modified assays were potentially more reliable (OD values close to 2), and of adequate sensitivity compared to the original assay in the detection of avian influenza viral antibodies in wild bird sera. Although further optimization of antigen and MAb concentrations should also be considered to increase the sensitivity of a modified assay, while maintaining acceptable optical density values for the MAb control. Post coating had a minimal quantitative effect on the results and stabilized the plates for 214 days. We therefore recommend the incorporation of post coating. </p>\",\"PeriodicalId\":50370,\"journal\":{\"name\":\"Indian Journal of Virology\",\"volume\":\"23 3\",\"pages\":\"261-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s13337-012-0074-3\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Virology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s13337-012-0074-3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/8/2 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Virology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s13337-012-0074-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/8/2 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

我们应用竞争性酶联免疫吸附法检测马血清中甲型流感抗体,以检测野生水禽血清中的甲型流感抗体。单克隆抗体(MAb)对照的光密度(OD)和重复分析之间的可重复性在初始评估中获得了不理想的结果。因此,有必要修改分析,以提供更高的可靠性和可重复性,同时保持足够的灵敏度。我们优化了试剂浓度,以获得单克隆抗体对照的最佳OD值(接近2),并使用2,2 '- azno -bis: 3-Benzthiazoline-6-Sulphonic Acid作为替代显色剂,以潜在地减少重复分析的可变性。将原方法与优化后的方法进行比较,分别对240份野生羽笛鸭血清进行禽流感病毒抗体检测。另外,对羽鸣鸭稀释阳性场血清进行了分析敏感性研究,并对抗原涂覆后的稳定性进行了测试。在原始测定法和修改后的测定法之间检测到一些定量差异。原始分析记录了更高百分比的抑制结果,这可能表明敏感性增加。然而,当试剂浓度在原始分析中增加到与修改版本中使用的相同水平时,没有实际目的的定量差异。原始分析产生的(单抗)对照的中位(OD)值为0.81,处于可接受的极限。相比之下,修改后的检测方法总是产生可接受的单克隆抗体对照光密度值。我们的总体结果表明,在检测野鸟血清中的禽流感病毒抗体时,与原始检测方法相比,改进的检测方法可能更可靠(OD值接近2),并且具有足够的灵敏度。虽然还应考虑进一步优化抗原和单抗浓度,以提高改进检测的灵敏度,同时保持单抗对照可接受的光密度值。后涂层对结果的定量影响很小,并稳定了214天。因此,我们建议合并后涂层。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Adaptations of a competitive enzyme-linked immunosorbent assays for the detection of antibodies to influenza a virus in horse sera for use in wild aquatic birds.

We applied a competitive enzyme-linked immunosorbent assay for the detection of antibodies for influenza A in equine sera to their detection in sera from wild aquatic birds. Suboptimal results were obtained for the optical density (OD) of the monoclonal antibody (MAb) control and reproducibility between duplicate analyses in the initial assessment. It was therefore necessary to modify the assay to deliver increased reliability and reproducibility while maintaining adequate sensitivity. We optimized reagent concentrations to obtain optimal OD values (close to 2) for the monoclonal antibody control and used 2, 2'-Azino-bis: 3-Benzthiazoline-6-Sulphonic Acid as an alternative chromogen to potentially reduce variability in duplicate analyses. The original assay was compared with the optimized versions, with and without post coating, for the detection of avian influenza viral antibodies in 240 sera obtained from wild plumed whistling ducks. A separate analytical sensitivity study on diluted positive field sera of plumed whistling ducks and a test of antigen stability after post coating were also performed. Some quantitative differences were detected between the original and modified assays. The original assay recorded higher percentage inhibition results which were potentially indicative of increased sensitivity. However, when reagent concentrations were increased in the original assay to the same levels as used in the modified versions, there were no quantitative differences for practical purposes. The original assay produced a median (OD) value of 0.81 for the (MAb) controls that is at the limit of acceptability. By contrast, the modified assays always produced acceptable optical density values for MAb controls. Our overall results indicated the modified assays were potentially more reliable (OD values close to 2), and of adequate sensitivity compared to the original assay in the detection of avian influenza viral antibodies in wild bird sera. Although further optimization of antigen and MAb concentrations should also be considered to increase the sensitivity of a modified assay, while maintaining acceptable optical density values for the MAb control. Post coating had a minimal quantitative effect on the results and stabilized the plates for 214 days. We therefore recommend the incorporation of post coating.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Journal of Virology
Indian Journal of Virology 医学-病毒学
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信