{"title":"修复表面长期氟化物交换及其对表面力学性能的影响。","authors":"Steven Naoum, Elizabeth Martin, Ayman Ellakwa","doi":"10.1155/2013/579039","DOIUrl":null,"url":null,"abstract":"<p><p>Aim. The aim of the study was to determine whether three fluoride containing resin composites could maintain fluoride release, fluoride recharge, and mechanical stability over long-term (18-month) aging. Materials and Methods. Fluoride containing composites Beautifil II, Gradia Direct X, Tetric EvoCeram, and glass ionomer Fuji IX Extra were analyzed. Specimens of each material were fabricated for two test groups: Group 1: bimonthly fluoride release/recharge analysis (n = 5); Group 2: hardness and elastic modulus analysis (n = 6). Nanoindentation was employed at 24 hours and at 1, 3, 6, 12, and 18 months. After 18 months, each specimen was immersed (recharged) in 5000 ppm NaF gel, and fluoride rerelease, hardness, and elastic modulus were measured. Results. Beautifil II and Gradia Direct X maintained fluoride release and recharge capability throughout 18-month aging (Beautifil II > Gradia Direct X > Tetric EvoCeram). The fluoride rerelease from Beautifil II following a 10-minute NaF recharge (at 18 months) was comparable to the long-term fluoride release from Fuji IX Extra. Elastic modulus and hardness did not change significantly (P > 0.05) with fluoride release, recharge, and water aging over 18 months for all three analyzed composites. Conclusions. The long-term fluoride release, fluoride recharge, and mechanical property stability of Beautifil II and Gradia Direct X render these composites suitable for load bearing restorations in high caries risk patients. Clinical Relevance. The ability for Beautifil II and Gradia Direct X to maintain fluoride release and fluoride recharge capability, despite long-term aging, raises the potential for unrestored tooth surfaces in contact with Beautifil II or Gradia Direct X restorations to demonstrate a reduced rate of caries incidence compared to unrestored surfaces adjacent to conventional nonfluoride containing composites. </p>","PeriodicalId":89396,"journal":{"name":"ISRN dentistry","volume":"2013 ","pages":"579039"},"PeriodicalIF":0.0000,"publicationDate":"2013-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2013/579039","citationCount":"15","resultStr":"{\"title\":\"Long-term fluoride exchanges at restoration surfaces and effects on surface mechanical properties.\",\"authors\":\"Steven Naoum, Elizabeth Martin, Ayman Ellakwa\",\"doi\":\"10.1155/2013/579039\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Aim. The aim of the study was to determine whether three fluoride containing resin composites could maintain fluoride release, fluoride recharge, and mechanical stability over long-term (18-month) aging. Materials and Methods. Fluoride containing composites Beautifil II, Gradia Direct X, Tetric EvoCeram, and glass ionomer Fuji IX Extra were analyzed. Specimens of each material were fabricated for two test groups: Group 1: bimonthly fluoride release/recharge analysis (n = 5); Group 2: hardness and elastic modulus analysis (n = 6). Nanoindentation was employed at 24 hours and at 1, 3, 6, 12, and 18 months. After 18 months, each specimen was immersed (recharged) in 5000 ppm NaF gel, and fluoride rerelease, hardness, and elastic modulus were measured. Results. Beautifil II and Gradia Direct X maintained fluoride release and recharge capability throughout 18-month aging (Beautifil II > Gradia Direct X > Tetric EvoCeram). The fluoride rerelease from Beautifil II following a 10-minute NaF recharge (at 18 months) was comparable to the long-term fluoride release from Fuji IX Extra. Elastic modulus and hardness did not change significantly (P > 0.05) with fluoride release, recharge, and water aging over 18 months for all three analyzed composites. Conclusions. The long-term fluoride release, fluoride recharge, and mechanical property stability of Beautifil II and Gradia Direct X render these composites suitable for load bearing restorations in high caries risk patients. Clinical Relevance. The ability for Beautifil II and Gradia Direct X to maintain fluoride release and fluoride recharge capability, despite long-term aging, raises the potential for unrestored tooth surfaces in contact with Beautifil II or Gradia Direct X restorations to demonstrate a reduced rate of caries incidence compared to unrestored surfaces adjacent to conventional nonfluoride containing composites. </p>\",\"PeriodicalId\":89396,\"journal\":{\"name\":\"ISRN dentistry\",\"volume\":\"2013 \",\"pages\":\"579039\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-08-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2013/579039\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISRN dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2013/579039\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2013/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2013/579039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15
摘要
的目标。该研究的目的是确定三种含氟树脂复合材料在长期(18个月)老化过程中是否能保持氟释放、氟补给和机械稳定性。材料与方法。分析了含氟复合材料Beautifil II、gradient Direct X、Tetric EvoCeram和玻璃离子聚合物Fuji IX Extra。每种材料的标本制作分为两个实验组:第1组:每两个月进行一次氟化物释放/补给分析(n = 5);第2组:硬度和弹性模量分析(n = 6)。纳米压痕在24小时和1、3、6、12和18个月时使用。18个月后,将每个样品浸入(再充电)在5000 ppm的NaF凝胶中,测量氟化物释放量、硬度和弹性模量。结果。在18个月的老化过程中,Beautifil II和Gradia Direct X保持了氟化物释放和补给能力(Beautifil II > Gradia Direct X > electric EvoCeram)。在10分钟NaF充电后(18个月),Beautifil II的氟化物释放量与富士IX Extra的长期氟化物释放量相当。在18个月以上,三种复合材料的弹性模量和硬度随氟释放、补给和水老化均无显著变化(P > 0.05)。结论。Beautifil II和grada Direct X的长期氟化物释放、氟化物补充和力学性能稳定性使其适合于高龋风险患者的负重修复。临床相关性。尽管长期老化,但Beautifil II和gradient Direct X保持氟化物释放和氟化物补充能力的能力,提高了与Beautifil II或gradient Direct X修复体接触的未修复牙齿表面的潜力,与传统不含氟化物的复合材料相邻的未修复表面相比,龋齿发病率降低。
Long-term fluoride exchanges at restoration surfaces and effects on surface mechanical properties.
Aim. The aim of the study was to determine whether three fluoride containing resin composites could maintain fluoride release, fluoride recharge, and mechanical stability over long-term (18-month) aging. Materials and Methods. Fluoride containing composites Beautifil II, Gradia Direct X, Tetric EvoCeram, and glass ionomer Fuji IX Extra were analyzed. Specimens of each material were fabricated for two test groups: Group 1: bimonthly fluoride release/recharge analysis (n = 5); Group 2: hardness and elastic modulus analysis (n = 6). Nanoindentation was employed at 24 hours and at 1, 3, 6, 12, and 18 months. After 18 months, each specimen was immersed (recharged) in 5000 ppm NaF gel, and fluoride rerelease, hardness, and elastic modulus were measured. Results. Beautifil II and Gradia Direct X maintained fluoride release and recharge capability throughout 18-month aging (Beautifil II > Gradia Direct X > Tetric EvoCeram). The fluoride rerelease from Beautifil II following a 10-minute NaF recharge (at 18 months) was comparable to the long-term fluoride release from Fuji IX Extra. Elastic modulus and hardness did not change significantly (P > 0.05) with fluoride release, recharge, and water aging over 18 months for all three analyzed composites. Conclusions. The long-term fluoride release, fluoride recharge, and mechanical property stability of Beautifil II and Gradia Direct X render these composites suitable for load bearing restorations in high caries risk patients. Clinical Relevance. The ability for Beautifil II and Gradia Direct X to maintain fluoride release and fluoride recharge capability, despite long-term aging, raises the potential for unrestored tooth surfaces in contact with Beautifil II or Gradia Direct X restorations to demonstrate a reduced rate of caries incidence compared to unrestored surfaces adjacent to conventional nonfluoride containing composites.