Ang Li, Qian Wang, Yang Gao, Jing Yang, Yu Wang, Xin-Kui Li
{"title":"开放式椎板成形术术前设计:计算机辅助形态计量学分析。","authors":"Ang Li, Qian Wang, Yang Gao, Jing Yang, Yu Wang, Xin-Kui Li","doi":"10.3109/10929088.2013.821169","DOIUrl":null,"url":null,"abstract":"<p><p>Whereas the expansive open-door laminoplasty (EL) has been applied widely and the bone gutter on the hinge side is essential for EL, little is known regarding the mandatory width of the bone gutter. This study addressed the essential parameters of bone gutters for EL. Preoperative axial CT images of 20 patients suffering from cervical myelopathy were downloaded and entered into a computer. EL was then simulated using a computer-assisted technique and the thickness of the laminae at the gutter sites was measured. Accordingly, the width of the bone gutter was linked mathematically with the angle of the lifted lamina and the thickness of the lamina at the lamina-lateral mass junction. Furthermore, the average thickness of the laminae at the gutter site was 6.19 mm, and the appropriate bone gutter for EL was 5.13 to 7.15 mm. The width of the bone gutter can thus be planned precisely preoperatively, which may help improve the safety and accuracy of expansive open-door laminoplasty.</p>","PeriodicalId":50644,"journal":{"name":"Computer Aided Surgery","volume":"18 5-6","pages":"201-4"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10929088.2013.821169","citationCount":"3","resultStr":"{\"title\":\"Preoperative design of expansive open-door laminoplasty: a computer-assisted morphometric analysis.\",\"authors\":\"Ang Li, Qian Wang, Yang Gao, Jing Yang, Yu Wang, Xin-Kui Li\",\"doi\":\"10.3109/10929088.2013.821169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Whereas the expansive open-door laminoplasty (EL) has been applied widely and the bone gutter on the hinge side is essential for EL, little is known regarding the mandatory width of the bone gutter. This study addressed the essential parameters of bone gutters for EL. Preoperative axial CT images of 20 patients suffering from cervical myelopathy were downloaded and entered into a computer. EL was then simulated using a computer-assisted technique and the thickness of the laminae at the gutter sites was measured. Accordingly, the width of the bone gutter was linked mathematically with the angle of the lifted lamina and the thickness of the lamina at the lamina-lateral mass junction. Furthermore, the average thickness of the laminae at the gutter site was 6.19 mm, and the appropriate bone gutter for EL was 5.13 to 7.15 mm. The width of the bone gutter can thus be planned precisely preoperatively, which may help improve the safety and accuracy of expansive open-door laminoplasty.</p>\",\"PeriodicalId\":50644,\"journal\":{\"name\":\"Computer Aided Surgery\",\"volume\":\"18 5-6\",\"pages\":\"201-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10929088.2013.821169\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Aided Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10929088.2013.821169\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2013/7/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Aided Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10929088.2013.821169","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/7/29 0:00:00","PubModel":"Epub","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
Preoperative design of expansive open-door laminoplasty: a computer-assisted morphometric analysis.
Whereas the expansive open-door laminoplasty (EL) has been applied widely and the bone gutter on the hinge side is essential for EL, little is known regarding the mandatory width of the bone gutter. This study addressed the essential parameters of bone gutters for EL. Preoperative axial CT images of 20 patients suffering from cervical myelopathy were downloaded and entered into a computer. EL was then simulated using a computer-assisted technique and the thickness of the laminae at the gutter sites was measured. Accordingly, the width of the bone gutter was linked mathematically with the angle of the lifted lamina and the thickness of the lamina at the lamina-lateral mass junction. Furthermore, the average thickness of the laminae at the gutter site was 6.19 mm, and the appropriate bone gutter for EL was 5.13 to 7.15 mm. The width of the bone gutter can thus be planned precisely preoperatively, which may help improve the safety and accuracy of expansive open-door laminoplasty.
期刊介绍:
The scope of Computer Aided Surgery encompasses all fields within surgery, as well as biomedical imaging and instrumentation, and digital technology employed as an adjunct to imaging in diagnosis, therapeutics, and surgery. Topics featured include frameless as well as conventional stereotaxic procedures, surgery guided by ultrasound, image guided focal irradiation, robotic surgery, and other therapeutic interventions that are performed with the use of digital imaging technology.