{"title":"SPY术中灌注评估系统减少乳房切除术后即刻重建中缺血性并发症的潜力。","authors":"Mohit Sood, Paul Glat","doi":"10.1186/1750-1164-7-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The quality and viability of mastectomy flaps remain a central challenge in reconstructive surgery, particularly for immediate breast reconstruction. Insufficient perfusion in tissue flaps is a leading cause of early complications following reconstructive procedures, and clinical judgment alone is not completely reliable for the assessment of flap viability. Accurate and reliable intraoperative methods for assessment of tissue perfusion are needed to help surgeons identify tissue at risk for ischemia and necrosis, thereby allowing for maneuvers to improve tissue flap viability.</p><p><strong>Methods: </strong>This study evaluates the use of intraoperative laser angiography using the SPY System (LifeCell Corp., Branchburg, NJ) for the assessment of perfusion in mastectomy flaps for immediate breast reconstruction. The SPY System uses the contrast agent indocyanine green, which has an excellent safety profile and pharmacokinetics that allow for repeat evaluations during the same surgical procedure. In recent work, the SPY System has demonstrated high sensitivity and specificity for detection of tissues at risk for ischemia and necrosis during reconstructive surgery. Using a retrospective, chart-review design, the authors compared consecutive cases of immediate breast reconstruction using a prosthesis, before and after implementation of the SPY System.</p><p><strong>Results: </strong>Ninety-one subjects were included in the analysis: 52 prior to SPY (Pre-SPY) and 39 after implementation of SPY (Post-SPY). Baseline characteristics were similar between the groups. Both groups had high rates of comorbidities, chemotherapy, and radiation therapy. The rate of postoperative complications was two-fold higher in the Pre-SPY group compared to the Post-SPY group (36.5% vs. 17.9%); this difference was of borderline significance (P = 0.0631). However, mean number of repeat visits to the OR per patient was significantly higher in the Pre-SPY group (1.21 ± 1.47 vs. 0.41 ± 0.71; P = 0.0023). Of the seven patients with complications in the Post-SPY group, five were identified by SPY as having poor flap perfusion; none were identified by clinical judgment alone.</p><p><strong>Conclusions: </strong>This study suggests that the SPY System can contribute to reduced ischemia-related complications in a population of women undergoing immediate breast reconstruction following mastectomy for breast cancer.</p>","PeriodicalId":87428,"journal":{"name":"Annals of surgical innovation and research","volume":"7 1","pages":"9"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/1750-1164-7-9","citationCount":"68","resultStr":"{\"title\":\"Potential of the SPY intraoperative perfusion assessment system to reduce ischemic complications in immediate postmastectomy breast reconstruction.\",\"authors\":\"Mohit Sood, Paul Glat\",\"doi\":\"10.1186/1750-1164-7-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The quality and viability of mastectomy flaps remain a central challenge in reconstructive surgery, particularly for immediate breast reconstruction. Insufficient perfusion in tissue flaps is a leading cause of early complications following reconstructive procedures, and clinical judgment alone is not completely reliable for the assessment of flap viability. Accurate and reliable intraoperative methods for assessment of tissue perfusion are needed to help surgeons identify tissue at risk for ischemia and necrosis, thereby allowing for maneuvers to improve tissue flap viability.</p><p><strong>Methods: </strong>This study evaluates the use of intraoperative laser angiography using the SPY System (LifeCell Corp., Branchburg, NJ) for the assessment of perfusion in mastectomy flaps for immediate breast reconstruction. The SPY System uses the contrast agent indocyanine green, which has an excellent safety profile and pharmacokinetics that allow for repeat evaluations during the same surgical procedure. In recent work, the SPY System has demonstrated high sensitivity and specificity for detection of tissues at risk for ischemia and necrosis during reconstructive surgery. Using a retrospective, chart-review design, the authors compared consecutive cases of immediate breast reconstruction using a prosthesis, before and after implementation of the SPY System.</p><p><strong>Results: </strong>Ninety-one subjects were included in the analysis: 52 prior to SPY (Pre-SPY) and 39 after implementation of SPY (Post-SPY). Baseline characteristics were similar between the groups. Both groups had high rates of comorbidities, chemotherapy, and radiation therapy. The rate of postoperative complications was two-fold higher in the Pre-SPY group compared to the Post-SPY group (36.5% vs. 17.9%); this difference was of borderline significance (P = 0.0631). However, mean number of repeat visits to the OR per patient was significantly higher in the Pre-SPY group (1.21 ± 1.47 vs. 0.41 ± 0.71; P = 0.0023). Of the seven patients with complications in the Post-SPY group, five were identified by SPY as having poor flap perfusion; none were identified by clinical judgment alone.</p><p><strong>Conclusions: </strong>This study suggests that the SPY System can contribute to reduced ischemia-related complications in a population of women undergoing immediate breast reconstruction following mastectomy for breast cancer.</p>\",\"PeriodicalId\":87428,\"journal\":{\"name\":\"Annals of surgical innovation and research\",\"volume\":\"7 1\",\"pages\":\"9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/1750-1164-7-9\",\"citationCount\":\"68\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of surgical innovation and research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/1750-1164-7-9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of surgical innovation and research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/1750-1164-7-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 68
摘要
背景:乳房切除术皮瓣的质量和生存能力仍然是重建手术的核心挑战,特别是对于立即乳房重建。组织皮瓣灌注不足是重建手术后早期并发症的主要原因,仅凭临床判断评估皮瓣活力并不完全可靠。需要准确可靠的术中组织灌注评估方法来帮助外科医生识别有缺血和坏死风险的组织,从而允许操作来提高组织瓣的活力。方法:本研究评估使用SPY系统(LifeCell Corp., Branchburg, NJ)术中激光血管造影评估乳房切除术皮瓣在立即乳房重建中的灌注情况。SPY系统使用造影剂吲哚菁绿,具有良好的安全性和药代动力学,允许在同一手术过程中重复评估。在最近的工作中,SPY系统在重建手术中检测有缺血和坏死危险的组织方面表现出了高灵敏度和特异性。采用回顾性、图表回顾设计,作者比较了SPY系统实施前后使用假体立即乳房重建的连续病例。结果:共纳入91例受试者,其中实施前52例(Pre-SPY),实施后39例(Post-SPY)。两组的基线特征相似。两组患者的合并症、化疗和放疗的发生率都很高。spy前组的术后并发症发生率是spy后组的2倍(36.5% vs. 17.9%);差异有临界意义(P = 0.0631)。然而,Pre-SPY组每位患者的平均重复就诊次数显著高于对照组(1.21±1.47 vs 0.41±0.71;p = 0.0023)。SPY后组出现并发症的7例患者中,有5例经SPY鉴定为皮瓣灌注不良;没有一个是单独通过临床判断确定的。结论:本研究表明SPY系统有助于减少乳腺癌切除术后立即进行乳房重建的女性人群中的缺血相关并发症。
Potential of the SPY intraoperative perfusion assessment system to reduce ischemic complications in immediate postmastectomy breast reconstruction.
Background: The quality and viability of mastectomy flaps remain a central challenge in reconstructive surgery, particularly for immediate breast reconstruction. Insufficient perfusion in tissue flaps is a leading cause of early complications following reconstructive procedures, and clinical judgment alone is not completely reliable for the assessment of flap viability. Accurate and reliable intraoperative methods for assessment of tissue perfusion are needed to help surgeons identify tissue at risk for ischemia and necrosis, thereby allowing for maneuvers to improve tissue flap viability.
Methods: This study evaluates the use of intraoperative laser angiography using the SPY System (LifeCell Corp., Branchburg, NJ) for the assessment of perfusion in mastectomy flaps for immediate breast reconstruction. The SPY System uses the contrast agent indocyanine green, which has an excellent safety profile and pharmacokinetics that allow for repeat evaluations during the same surgical procedure. In recent work, the SPY System has demonstrated high sensitivity and specificity for detection of tissues at risk for ischemia and necrosis during reconstructive surgery. Using a retrospective, chart-review design, the authors compared consecutive cases of immediate breast reconstruction using a prosthesis, before and after implementation of the SPY System.
Results: Ninety-one subjects were included in the analysis: 52 prior to SPY (Pre-SPY) and 39 after implementation of SPY (Post-SPY). Baseline characteristics were similar between the groups. Both groups had high rates of comorbidities, chemotherapy, and radiation therapy. The rate of postoperative complications was two-fold higher in the Pre-SPY group compared to the Post-SPY group (36.5% vs. 17.9%); this difference was of borderline significance (P = 0.0631). However, mean number of repeat visits to the OR per patient was significantly higher in the Pre-SPY group (1.21 ± 1.47 vs. 0.41 ± 0.71; P = 0.0023). Of the seven patients with complications in the Post-SPY group, five were identified by SPY as having poor flap perfusion; none were identified by clinical judgment alone.
Conclusions: This study suggests that the SPY System can contribute to reduced ischemia-related complications in a population of women undergoing immediate breast reconstruction following mastectomy for breast cancer.