利用低电流x射线和光子计数CZT探测器进行多材料分解。

Sangtaek Kim, Andrew Hernandez, Fares Alhassen, Michael Pivovaroff, Hyo-Min Cho, Robert G Gould, Youngho Seo
{"title":"利用低电流x射线和光子计数CZT探测器进行多材料分解。","authors":"Sangtaek Kim,&nbsp;Andrew Hernandez,&nbsp;Fares Alhassen,&nbsp;Michael Pivovaroff,&nbsp;Hyo-Min Cho,&nbsp;Robert G Gould,&nbsp;Youngho Seo","doi":"10.1109/nssmic.2011.6154705","DOIUrl":null,"url":null,"abstract":"<p><p>We developed and evaluated an x-ray photon-counting imaging system using an energy-resolving cadmium zinc telluride (CZT) detector coupled with application specific integrated circuit (ASIC) readouts. This x-ray imaging system can be used to identify different materials inside the object. The CZT detector has a large active area (5×5 array of 25 CZT modules, each with 16×16 pixels, cover a total area of 200 mm × 200 mm), high stopping efficiency for x-ray photons (~ 100 % at 60 keV and 5 mm thickness). We explored the performance of this system by applying different energy windows around the absorption edges of target materials, silver and indium, in order to distinguish one material from another. The photon-counting CZT-based x-ray imaging system was able to distinguish between the materials, demonstrating its capability as a radiation-spectroscopic decomposition system.</p>","PeriodicalId":73298,"journal":{"name":"IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium","volume":" ","pages":"4735-4738"},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/nssmic.2011.6154705","citationCount":"0","resultStr":"{\"title\":\"Multi-Material Decomposition using Low-Current X-Ray and a Photon-Counting CZT Detector.\",\"authors\":\"Sangtaek Kim,&nbsp;Andrew Hernandez,&nbsp;Fares Alhassen,&nbsp;Michael Pivovaroff,&nbsp;Hyo-Min Cho,&nbsp;Robert G Gould,&nbsp;Youngho Seo\",\"doi\":\"10.1109/nssmic.2011.6154705\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We developed and evaluated an x-ray photon-counting imaging system using an energy-resolving cadmium zinc telluride (CZT) detector coupled with application specific integrated circuit (ASIC) readouts. This x-ray imaging system can be used to identify different materials inside the object. The CZT detector has a large active area (5×5 array of 25 CZT modules, each with 16×16 pixels, cover a total area of 200 mm × 200 mm), high stopping efficiency for x-ray photons (~ 100 % at 60 keV and 5 mm thickness). We explored the performance of this system by applying different energy windows around the absorption edges of target materials, silver and indium, in order to distinguish one material from another. The photon-counting CZT-based x-ray imaging system was able to distinguish between the materials, demonstrating its capability as a radiation-spectroscopic decomposition system.</p>\",\"PeriodicalId\":73298,\"journal\":{\"name\":\"IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium\",\"volume\":\" \",\"pages\":\"4735-4738\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/nssmic.2011.6154705\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/nssmic.2011.6154705\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/nssmic.2011.6154705","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们开发并评估了一种x射线光子计数成像系统,该系统使用能量分辨碲化镉锌(CZT)探测器与专用集成电路(ASIC)读数相结合。这种x射线成像系统可用于识别物体内部的不同材料。该CZT探测器具有较大的有效面积(5×5由25个CZT模块组成的阵列,每个模块有16×16个像素,覆盖总面积为200mm × 200mm),对x射线光子的拦截效率高(在60kev和5mm厚度下达到100%)。我们通过在目标材料(银和铟)的吸收边缘周围应用不同的能量窗来探索该系统的性能,以区分不同的材料。基于光子计数cts的x射线成像系统能够区分材料,证明其作为辐射光谱分解系统的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multi-Material Decomposition using Low-Current X-Ray and a Photon-Counting CZT Detector.

We developed and evaluated an x-ray photon-counting imaging system using an energy-resolving cadmium zinc telluride (CZT) detector coupled with application specific integrated circuit (ASIC) readouts. This x-ray imaging system can be used to identify different materials inside the object. The CZT detector has a large active area (5×5 array of 25 CZT modules, each with 16×16 pixels, cover a total area of 200 mm × 200 mm), high stopping efficiency for x-ray photons (~ 100 % at 60 keV and 5 mm thickness). We explored the performance of this system by applying different energy windows around the absorption edges of target materials, silver and indium, in order to distinguish one material from another. The photon-counting CZT-based x-ray imaging system was able to distinguish between the materials, demonstrating its capability as a radiation-spectroscopic decomposition system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信