{"title":"牙齿颜色测量设备是否符合CIE标准?","authors":"Karl Martin Lehmann,&nbsp;Alessandro Devigus,&nbsp;Christopher Igiel,&nbsp;Michael Weyhrauch,&nbsp;Irene Schmidtmann,&nbsp;Stefan Wentaschek,&nbsp;Herbert Scheller","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This in vitro study evaluated the accordance of dental color measurement devices with a Commission Internationale de l'Eclairage (CIE)-compliant reference system, by comparing the CIE lightness, chroma, and hue (L*C*h°) color coordinates of ceramic samples.</p><p><strong>Methods: </strong>Four color measurement devices: Vita Easyshade® Advance (A); DeguDent Shadepilot™ (B); X-Rite® Shadevision (C); and Crystaleye Olympus (D), were compared with a CIE-compliant reference system by recording the L*C*h° color coordinates of ceramic samples matching the tooth colors of the Vita Linearguide 3D-Master®, under standardized test conditions. Differences between regression lines for the dental color measurement device data and regression lines for the CIE-compliant reference system data were evaluated.</p><p><strong>Results: </strong>All devices offered high intraclass correlation coefficients (0.9771- 0.9999) for the L*C*h° color coordinates. The regression lines of the L* and C* coordinates for device A were steeper than those of the CIE-compliant reference system; the regression lines for devices B, C, and D were nearly parallel to those of the reference system, but with an offset. The regression lines of the h° coordinates for all devices were almost parallel to those of the reference system, with slopes near 1. Excluding the L* and h° coordinate measurements of device A, the measurements with the devices exhibited deviations from the reference system that were greater than those expected by chance (P < 0.0002).</p><p><strong>Conclusions: </strong>The dental color measurement devices assessed here offered excellent reproducibility, but showed significant deviations from the CIE-compliant reference system regarding the L*C*h° color coordinates.</p>","PeriodicalId":88322,"journal":{"name":"The European journal of esthetic dentistry : official journal of the European Academy of Esthetic Dentistry","volume":"7 3","pages":"324-33"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Are dental color measuring devices CIE compliant?\",\"authors\":\"Karl Martin Lehmann,&nbsp;Alessandro Devigus,&nbsp;Christopher Igiel,&nbsp;Michael Weyhrauch,&nbsp;Irene Schmidtmann,&nbsp;Stefan Wentaschek,&nbsp;Herbert Scheller\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This in vitro study evaluated the accordance of dental color measurement devices with a Commission Internationale de l'Eclairage (CIE)-compliant reference system, by comparing the CIE lightness, chroma, and hue (L*C*h°) color coordinates of ceramic samples.</p><p><strong>Methods: </strong>Four color measurement devices: Vita Easyshade® Advance (A); DeguDent Shadepilot™ (B); X-Rite® Shadevision (C); and Crystaleye Olympus (D), were compared with a CIE-compliant reference system by recording the L*C*h° color coordinates of ceramic samples matching the tooth colors of the Vita Linearguide 3D-Master®, under standardized test conditions. Differences between regression lines for the dental color measurement device data and regression lines for the CIE-compliant reference system data were evaluated.</p><p><strong>Results: </strong>All devices offered high intraclass correlation coefficients (0.9771- 0.9999) for the L*C*h° color coordinates. The regression lines of the L* and C* coordinates for device A were steeper than those of the CIE-compliant reference system; the regression lines for devices B, C, and D were nearly parallel to those of the reference system, but with an offset. The regression lines of the h° coordinates for all devices were almost parallel to those of the reference system, with slopes near 1. Excluding the L* and h° coordinate measurements of device A, the measurements with the devices exhibited deviations from the reference system that were greater than those expected by chance (P < 0.0002).</p><p><strong>Conclusions: </strong>The dental color measurement devices assessed here offered excellent reproducibility, but showed significant deviations from the CIE-compliant reference system regarding the L*C*h° color coordinates.</p>\",\"PeriodicalId\":88322,\"journal\":{\"name\":\"The European journal of esthetic dentistry : official journal of the European Academy of Esthetic Dentistry\",\"volume\":\"7 3\",\"pages\":\"324-33\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The European journal of esthetic dentistry : official journal of the European Academy of Esthetic Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The European journal of esthetic dentistry : official journal of the European Academy of Esthetic Dentistry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本体外研究通过比较陶瓷样品的CIE明度、色度和色相(l *C*h°)颜色坐标,评价牙体颜色测量装置与符合CIE标准的参考系统的一致性。方法:四种颜色测量装置:Vita easysshade®Advance (A);DeguDent Shadepilot ' (B);X-Rite®Shadevision (C);和Crystaleye Olympus (D),通过在标准化测试条件下记录与Vita Linearguide 3D-Master®牙齿颜色匹配的陶瓷样品的L*C*h°颜色坐标,与符合cie标准的参考系统进行比较。评估牙齿颜色测量装置数据的回归线与cie标准参考系统数据的回归线之间的差异。结果:所有设备的L*C*h°颜色坐标均具有较高的类内相关系数(0.9771 ~ 0.9999)。设备A的L*和C*坐标的回归线比符合cie标准的参照系的回归线更陡;设备B、C和D的回归线与参考系统的回归线几乎平行,但有偏移。各装置的h°坐标回归线与参照系的回归线基本平行,斜率均在1附近。排除设备A的L*和h°坐标测量,设备测量结果与参考系统的偏差大于偶然预期(P < 0.0002)。结论:本研究评估的牙齿颜色测量装置具有良好的再现性,但在L*C*h°颜色坐标方面与cie标准参考系统存在显著偏差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Are dental color measuring devices CIE compliant?

Objectives: This in vitro study evaluated the accordance of dental color measurement devices with a Commission Internationale de l'Eclairage (CIE)-compliant reference system, by comparing the CIE lightness, chroma, and hue (L*C*h°) color coordinates of ceramic samples.

Methods: Four color measurement devices: Vita Easyshade® Advance (A); DeguDent Shadepilot™ (B); X-Rite® Shadevision (C); and Crystaleye Olympus (D), were compared with a CIE-compliant reference system by recording the L*C*h° color coordinates of ceramic samples matching the tooth colors of the Vita Linearguide 3D-Master®, under standardized test conditions. Differences between regression lines for the dental color measurement device data and regression lines for the CIE-compliant reference system data were evaluated.

Results: All devices offered high intraclass correlation coefficients (0.9771- 0.9999) for the L*C*h° color coordinates. The regression lines of the L* and C* coordinates for device A were steeper than those of the CIE-compliant reference system; the regression lines for devices B, C, and D were nearly parallel to those of the reference system, but with an offset. The regression lines of the h° coordinates for all devices were almost parallel to those of the reference system, with slopes near 1. Excluding the L* and h° coordinate measurements of device A, the measurements with the devices exhibited deviations from the reference system that were greater than those expected by chance (P < 0.0002).

Conclusions: The dental color measurement devices assessed here offered excellent reproducibility, but showed significant deviations from the CIE-compliant reference system regarding the L*C*h° color coordinates.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信