被动沉积取样器的设计与验证。

Journal of Environmental Monitoring Pub Date : 2012-09-01 Epub Date: 2012-07-23 DOI:10.1039/c2em30174a
Stephanie A Einstein, Chang-Ho Yu, Gediminas Mainelis, Lung Chi Chen, Clifford P Weisel, Paul J Lioy
{"title":"被动沉积取样器的设计与验证。","authors":"Stephanie A Einstein,&nbsp;Chang-Ho Yu,&nbsp;Gediminas Mainelis,&nbsp;Lung Chi Chen,&nbsp;Clifford P Weisel,&nbsp;Paul J Lioy","doi":"10.1039/c2em30174a","DOIUrl":null,"url":null,"abstract":"<p><p>A new, passive particle deposition air sampler, called the Einstein-Lioy Deposition Sampler (ELDS), has been developed to fill a gap in passive sampling for near-field particle emissions. The sampler can be configured in several ways: with a protective hood for outdoor sampling, without a protective hood, and as a dust plate. In addition, there is an XRF-ready option that allows for direct sampling onto a filter-mounted XRF cartridge which can be used in conjunction with all configurations. A wind tunnel was designed and constructed to test the performance of different sampler configurations using a test dust with a known particle size distribution. The sampler configurations were also tested versus each other to evaluate whether or not the protective hood would affect the collected particle size distribution. A field study was conducted to test the sampler under actual environmental conditions and to evaluate its ability to collect samples for chemical analysis. Individual experiments for each configuration demonstrated precision of the sampler. The field experiment demonstrated the ability of the sampler to both collect mass and allow for the measurement of an environmental contaminant i.e. Cr(6+). The ELDS was demonstrated to be statistically not different for Hooded and Non-Hooded models, compared to each other and the test dust; thus, it can be used indoors and outdoors in a variety of configurations to suit the user's needs.</p>","PeriodicalId":50202,"journal":{"name":"Journal of Environmental Monitoring","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1039/c2em30174a","citationCount":"10","resultStr":"{\"title\":\"Design and validation of a passive deposition sampler.\",\"authors\":\"Stephanie A Einstein,&nbsp;Chang-Ho Yu,&nbsp;Gediminas Mainelis,&nbsp;Lung Chi Chen,&nbsp;Clifford P Weisel,&nbsp;Paul J Lioy\",\"doi\":\"10.1039/c2em30174a\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A new, passive particle deposition air sampler, called the Einstein-Lioy Deposition Sampler (ELDS), has been developed to fill a gap in passive sampling for near-field particle emissions. The sampler can be configured in several ways: with a protective hood for outdoor sampling, without a protective hood, and as a dust plate. In addition, there is an XRF-ready option that allows for direct sampling onto a filter-mounted XRF cartridge which can be used in conjunction with all configurations. A wind tunnel was designed and constructed to test the performance of different sampler configurations using a test dust with a known particle size distribution. The sampler configurations were also tested versus each other to evaluate whether or not the protective hood would affect the collected particle size distribution. A field study was conducted to test the sampler under actual environmental conditions and to evaluate its ability to collect samples for chemical analysis. Individual experiments for each configuration demonstrated precision of the sampler. The field experiment demonstrated the ability of the sampler to both collect mass and allow for the measurement of an environmental contaminant i.e. Cr(6+). The ELDS was demonstrated to be statistically not different for Hooded and Non-Hooded models, compared to each other and the test dust; thus, it can be used indoors and outdoors in a variety of configurations to suit the user's needs.</p>\",\"PeriodicalId\":50202,\"journal\":{\"name\":\"Journal of Environmental Monitoring\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1039/c2em30174a\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Environmental Monitoring\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1039/c2em30174a\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/7/23 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Monitoring","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1039/c2em30174a","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/7/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

一种新型的被动粒子沉积空气采样器,称为爱因斯坦- lioy沉积采样器(ELDS),已经开发出来,填补了近场粒子发射被动采样的空白。该采样器可配置为几种方式:带室外采样保护罩,不带保护罩,作为防尘板。此外,还有一个XRF-ready选项,允许直接采样到一个过滤器安装的XRF盒,可以与所有配置一起使用。设计并构建了风洞,利用已知粒径分布的试验粉尘测试不同采样器配置的性能。还对采样器的配置进行了对比测试,以评估防护罩是否会影响收集到的粒径分布。进行了实地研究,在实际环境条件下测试采样器,并评估其收集样品进行化学分析的能力。每个配置的单独实验证明了采样器的精度。现场实验证明了采样器既能收集质量,又能测量环境污染物,即Cr(6+)。结果表明,与试验粉尘相比,有兜帽和无兜帽模型的ELDS在统计学上没有差异;因此,它可以在室内和室外以各种配置使用,以满足用户的需求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design and validation of a passive deposition sampler.

A new, passive particle deposition air sampler, called the Einstein-Lioy Deposition Sampler (ELDS), has been developed to fill a gap in passive sampling for near-field particle emissions. The sampler can be configured in several ways: with a protective hood for outdoor sampling, without a protective hood, and as a dust plate. In addition, there is an XRF-ready option that allows for direct sampling onto a filter-mounted XRF cartridge which can be used in conjunction with all configurations. A wind tunnel was designed and constructed to test the performance of different sampler configurations using a test dust with a known particle size distribution. The sampler configurations were also tested versus each other to evaluate whether or not the protective hood would affect the collected particle size distribution. A field study was conducted to test the sampler under actual environmental conditions and to evaluate its ability to collect samples for chemical analysis. Individual experiments for each configuration demonstrated precision of the sampler. The field experiment demonstrated the ability of the sampler to both collect mass and allow for the measurement of an environmental contaminant i.e. Cr(6+). The ELDS was demonstrated to be statistically not different for Hooded and Non-Hooded models, compared to each other and the test dust; thus, it can be used indoors and outdoors in a variety of configurations to suit the user's needs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Environmental Monitoring
Journal of Environmental Monitoring 环境科学-分析化学
自引率
0.00%
发文量
0
审稿时长
2.3 months
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信