Vinay Dhir, Boon Eu Andrew Kwek, Suryaprakash Bhandari, Mukta Bapat, Amit Maydeo
{"title":"eus引导胆道交会使用短亲水导丝。","authors":"Vinay Dhir, Boon Eu Andrew Kwek, Suryaprakash Bhandari, Mukta Bapat, Amit Maydeo","doi":"10.4161/jig.19967","DOIUrl":null,"url":null,"abstract":"<p><p>BACKGROUND AND STUDY AIMS: EUS-guided rendezvous technique for biliary access requires expert manipulation of the guidewire across the downstream stricture or papilla. Published literature reports usage of the long-wire system to prevent loss of wire during scope exchange. We studied the efficacy of using a short hydrophilic guidewire in EUS-guided rendezvous. PATIENTS AND METHODS: This is a retrospective study conducted in a tertiary care referral centre. 15 patients underwent EUS-guided biliary rendezvous with short wire. EUS-guided transduodenal/transgastric puncture of the biliary system was performed, followed by anterograde placement of a hydrophilic short-wire (260 cm) across the downstream stricture and/or papilla. Retrograde access was then achieved by retrieving the trans-papillary wire, followed by standard ERCP intervention. Main outcome measurements were rates of procedural success and complications. RESULTS: EUS-guided biliary rendezvous was successful in 14 patients (93.3%). Failure was seen in one patient due to a tight malignant biliary stricture. One patient had peri-choledochal bile tracking which did not require any specific treatment. CONCLUSIONS: Short-wire system in EUS-guided biliary rendezvous is highly effective and safe. It is a useful salvage procedure for biliary cannulation in patients with accessible papilla.</p>","PeriodicalId":89416,"journal":{"name":"Journal of interventional gastroenterology","volume":"1 4","pages":"153-159"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350886/pdf/jig0104_0153.pdf","citationCount":"21","resultStr":"{\"title\":\"EUS-guided biliary rendezvous using a short hydrophilic guidewire.\",\"authors\":\"Vinay Dhir, Boon Eu Andrew Kwek, Suryaprakash Bhandari, Mukta Bapat, Amit Maydeo\",\"doi\":\"10.4161/jig.19967\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>BACKGROUND AND STUDY AIMS: EUS-guided rendezvous technique for biliary access requires expert manipulation of the guidewire across the downstream stricture or papilla. Published literature reports usage of the long-wire system to prevent loss of wire during scope exchange. We studied the efficacy of using a short hydrophilic guidewire in EUS-guided rendezvous. PATIENTS AND METHODS: This is a retrospective study conducted in a tertiary care referral centre. 15 patients underwent EUS-guided biliary rendezvous with short wire. EUS-guided transduodenal/transgastric puncture of the biliary system was performed, followed by anterograde placement of a hydrophilic short-wire (260 cm) across the downstream stricture and/or papilla. Retrograde access was then achieved by retrieving the trans-papillary wire, followed by standard ERCP intervention. Main outcome measurements were rates of procedural success and complications. RESULTS: EUS-guided biliary rendezvous was successful in 14 patients (93.3%). Failure was seen in one patient due to a tight malignant biliary stricture. One patient had peri-choledochal bile tracking which did not require any specific treatment. CONCLUSIONS: Short-wire system in EUS-guided biliary rendezvous is highly effective and safe. It is a useful salvage procedure for biliary cannulation in patients with accessible papilla.</p>\",\"PeriodicalId\":89416,\"journal\":{\"name\":\"Journal of interventional gastroenterology\",\"volume\":\"1 4\",\"pages\":\"153-159\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350886/pdf/jig0104_0153.pdf\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of interventional gastroenterology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4161/jig.19967\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of interventional gastroenterology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4161/jig.19967","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
EUS-guided biliary rendezvous using a short hydrophilic guidewire.
BACKGROUND AND STUDY AIMS: EUS-guided rendezvous technique for biliary access requires expert manipulation of the guidewire across the downstream stricture or papilla. Published literature reports usage of the long-wire system to prevent loss of wire during scope exchange. We studied the efficacy of using a short hydrophilic guidewire in EUS-guided rendezvous. PATIENTS AND METHODS: This is a retrospective study conducted in a tertiary care referral centre. 15 patients underwent EUS-guided biliary rendezvous with short wire. EUS-guided transduodenal/transgastric puncture of the biliary system was performed, followed by anterograde placement of a hydrophilic short-wire (260 cm) across the downstream stricture and/or papilla. Retrograde access was then achieved by retrieving the trans-papillary wire, followed by standard ERCP intervention. Main outcome measurements were rates of procedural success and complications. RESULTS: EUS-guided biliary rendezvous was successful in 14 patients (93.3%). Failure was seen in one patient due to a tight malignant biliary stricture. One patient had peri-choledochal bile tracking which did not require any specific treatment. CONCLUSIONS: Short-wire system in EUS-guided biliary rendezvous is highly effective and safe. It is a useful salvage procedure for biliary cannulation in patients with accessible papilla.