{"title":"细胞对钴铬和CP钛的反应——种植体保留口腔假体框架的体外比较。","authors":"Lars Hjalmarsson, Jan-Ivan Smedberg, Gunilla Aronsson, Ann Wennerberg","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The responses of cell types in peri-implant tissues to cobalt-chrome and titanium were studied in vitro. Cylinders were made from both a cobalt-chrome alloy and commercially pure titanium (length 6 mm, diameter 7.9 mm). Plastic tubes were placed over the cylinders to create cell culture wells, in which human epithelial cells or mouse fibroblasts were cultivated. Cell viability was studied using the Alamar Blue method. The surface structure of two samples of each material was analyzed with optical interferometry. The morphology of cells grown on cylinders of each material was studied with scanning electronic microscopy. Epithelial cells and fibroblasts in the titanium group were more viable than those in the cobalt-chrome group (p = 0.001 and p = 0.000, respectively). The titanium surfaces had a greater height deviation (S(a), p = 0.027) but were less dense (S(ds), p = 0.044) than the cobalt-chrome group. The scanning electronic microscopy revealed no major deviations from normal cell morphology. Within the limitations of the present study, the findings indicate that epithelial cells as well as fibroblasts have a stronger negative response to cobalt-chrome alloy than to titanium. We suggest that these differences can be explained only bythe material per se and not by the minor differences in surface structure. Further and clinical studies are needed to confirm the significance of these findings.</p>","PeriodicalId":22114,"journal":{"name":"Swedish dental journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cellular responses to cobalt-chrome and CP titanium--an in vitro comparison of frameworks for implant-retained oral prostheses.\",\"authors\":\"Lars Hjalmarsson, Jan-Ivan Smedberg, Gunilla Aronsson, Ann Wennerberg\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The responses of cell types in peri-implant tissues to cobalt-chrome and titanium were studied in vitro. Cylinders were made from both a cobalt-chrome alloy and commercially pure titanium (length 6 mm, diameter 7.9 mm). Plastic tubes were placed over the cylinders to create cell culture wells, in which human epithelial cells or mouse fibroblasts were cultivated. Cell viability was studied using the Alamar Blue method. The surface structure of two samples of each material was analyzed with optical interferometry. The morphology of cells grown on cylinders of each material was studied with scanning electronic microscopy. Epithelial cells and fibroblasts in the titanium group were more viable than those in the cobalt-chrome group (p = 0.001 and p = 0.000, respectively). The titanium surfaces had a greater height deviation (S(a), p = 0.027) but were less dense (S(ds), p = 0.044) than the cobalt-chrome group. The scanning electronic microscopy revealed no major deviations from normal cell morphology. Within the limitations of the present study, the findings indicate that epithelial cells as well as fibroblasts have a stronger negative response to cobalt-chrome alloy than to titanium. We suggest that these differences can be explained only bythe material per se and not by the minor differences in surface structure. Further and clinical studies are needed to confirm the significance of these findings.</p>\",\"PeriodicalId\":22114,\"journal\":{\"name\":\"Swedish dental journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Swedish dental journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Swedish dental journal","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
摘要
体外研究了种植体周围组织细胞类型对钴铬和钛的反应。圆柱体由钴铬合金和商业纯钛(长6毫米,直径7.9毫米)制成。将塑料管置于圆柱体上形成细胞培养孔,在其中培养人上皮细胞或小鼠成纤维细胞。用Alamar Blue法研究细胞活力。用光学干涉法分析了每种材料的两个样品的表面结构。用扫描电镜研究了每种材料在圆柱体上生长的细胞形态。钛组上皮细胞和成纤维细胞活力高于钴铬组(p = 0.001和p = 0.000)。钛表面高度偏差大于钴铬组(S(a), p = 0.027),密度小于钴铬组(S(ds), p = 0.044)。扫描电镜显示与正常细胞形态无明显差异。在本研究的限制下,研究结果表明上皮细胞和成纤维细胞对钴铬合金的负反应比对钛的负反应更强。我们认为这些差异只能用材料本身来解释,而不能用表面结构的微小差异来解释。需要进一步的临床研究来证实这些发现的意义。
Cellular responses to cobalt-chrome and CP titanium--an in vitro comparison of frameworks for implant-retained oral prostheses.
The responses of cell types in peri-implant tissues to cobalt-chrome and titanium were studied in vitro. Cylinders were made from both a cobalt-chrome alloy and commercially pure titanium (length 6 mm, diameter 7.9 mm). Plastic tubes were placed over the cylinders to create cell culture wells, in which human epithelial cells or mouse fibroblasts were cultivated. Cell viability was studied using the Alamar Blue method. The surface structure of two samples of each material was analyzed with optical interferometry. The morphology of cells grown on cylinders of each material was studied with scanning electronic microscopy. Epithelial cells and fibroblasts in the titanium group were more viable than those in the cobalt-chrome group (p = 0.001 and p = 0.000, respectively). The titanium surfaces had a greater height deviation (S(a), p = 0.027) but were less dense (S(ds), p = 0.044) than the cobalt-chrome group. The scanning electronic microscopy revealed no major deviations from normal cell morphology. Within the limitations of the present study, the findings indicate that epithelial cells as well as fibroblasts have a stronger negative response to cobalt-chrome alloy than to titanium. We suggest that these differences can be explained only bythe material per se and not by the minor differences in surface structure. Further and clinical studies are needed to confirm the significance of these findings.
期刊介绍:
Swedish Dental Journal is the scientific journal of the Swedish Dental Association and the Swedish Dental Society. It is published 4 times a year to promote practice, education and research within odontology. Manuscripts containing original research are accepted for consideraion if neither the article nor any part of its essential substance has been or will be published elsewhere. Reviews, Case Reports and Short Communications will also be considered for publication.