{"title":"[牛肉肠出血性大肠杆菌O111的检测方法:合作研究]。","authors":"Midori Hiroi, Kayoko Ohtsuka, Shinji Iizuka, Kenichiro Taga, Kanji Sugiyamai, Yoshiko Sugita-Konishi, Yukiko Hara-Kudo","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>To establish a detection method for enterohemorrhagic Escherichia coli (EHEC) O111 in meat, a single-laboratory evaluation and a collaborative study were conducted focusing on comparisons of the efficiencies in combination with enrichment, a direct plating method and a plating method with immunomagnetic separation (IMS-plating method) using various agar media for EHEC O111, loop-mediated isothermal amplification (LAMP) assay targeting the Verocytotoxin (VT) gene as a molecular detection method. On a single-laboratory evaluation, enrichment in modified EC at 36 degrees C was inferior to that in modified EC supplemented with novobiocin (NmEC) and mEC at 42 degrees C to isolate EHEC O111 by plating methods. On a collaborative study, there were no significant differences between combinations of enrichment in NmEC at 42 degrees C-LAMP assay and enrichment in mEC at 42 degrees C-LAMP assay. The combinations of enrichment in NmEC at 42 degrees C-direct plating and enrichment in NmEC at 42 degrees C-IMS-plating were superior to combinations of enrichment in mEC at 42 degrees C-direct plating and enrichment in mEC at 42 degrees C-IMS-plating (p<0.05). There were no significant differences among the six different agar media by the direct plating and IMS-plating methods. As a result, it was suggested that the following methods are adequate for detection of EHEC O111 in beef: combinations of enrichment in NmEC at 42 degrees C, and direct plating and IMS-plating methods, or LAMP assay as a screening assay to detect VT gene followed by direct plating and IMS-plating methods.</p>","PeriodicalId":35462,"journal":{"name":"Bulletin of National Institute of Health Sciences","volume":" 129","pages":"61-7"},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Detection methods of enterohemorrhagic Escherichia coli O111 in beef: a collaborative study].\",\"authors\":\"Midori Hiroi, Kayoko Ohtsuka, Shinji Iizuka, Kenichiro Taga, Kanji Sugiyamai, Yoshiko Sugita-Konishi, Yukiko Hara-Kudo\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>To establish a detection method for enterohemorrhagic Escherichia coli (EHEC) O111 in meat, a single-laboratory evaluation and a collaborative study were conducted focusing on comparisons of the efficiencies in combination with enrichment, a direct plating method and a plating method with immunomagnetic separation (IMS-plating method) using various agar media for EHEC O111, loop-mediated isothermal amplification (LAMP) assay targeting the Verocytotoxin (VT) gene as a molecular detection method. On a single-laboratory evaluation, enrichment in modified EC at 36 degrees C was inferior to that in modified EC supplemented with novobiocin (NmEC) and mEC at 42 degrees C to isolate EHEC O111 by plating methods. On a collaborative study, there were no significant differences between combinations of enrichment in NmEC at 42 degrees C-LAMP assay and enrichment in mEC at 42 degrees C-LAMP assay. The combinations of enrichment in NmEC at 42 degrees C-direct plating and enrichment in NmEC at 42 degrees C-IMS-plating were superior to combinations of enrichment in mEC at 42 degrees C-direct plating and enrichment in mEC at 42 degrees C-IMS-plating (p<0.05). There were no significant differences among the six different agar media by the direct plating and IMS-plating methods. As a result, it was suggested that the following methods are adequate for detection of EHEC O111 in beef: combinations of enrichment in NmEC at 42 degrees C, and direct plating and IMS-plating methods, or LAMP assay as a screening assay to detect VT gene followed by direct plating and IMS-plating methods.</p>\",\"PeriodicalId\":35462,\"journal\":{\"name\":\"Bulletin of National Institute of Health Sciences\",\"volume\":\" 129\",\"pages\":\"61-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of National Institute of Health Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of National Institute of Health Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
[Detection methods of enterohemorrhagic Escherichia coli O111 in beef: a collaborative study].
To establish a detection method for enterohemorrhagic Escherichia coli (EHEC) O111 in meat, a single-laboratory evaluation and a collaborative study were conducted focusing on comparisons of the efficiencies in combination with enrichment, a direct plating method and a plating method with immunomagnetic separation (IMS-plating method) using various agar media for EHEC O111, loop-mediated isothermal amplification (LAMP) assay targeting the Verocytotoxin (VT) gene as a molecular detection method. On a single-laboratory evaluation, enrichment in modified EC at 36 degrees C was inferior to that in modified EC supplemented with novobiocin (NmEC) and mEC at 42 degrees C to isolate EHEC O111 by plating methods. On a collaborative study, there were no significant differences between combinations of enrichment in NmEC at 42 degrees C-LAMP assay and enrichment in mEC at 42 degrees C-LAMP assay. The combinations of enrichment in NmEC at 42 degrees C-direct plating and enrichment in NmEC at 42 degrees C-IMS-plating were superior to combinations of enrichment in mEC at 42 degrees C-direct plating and enrichment in mEC at 42 degrees C-IMS-plating (p<0.05). There were no significant differences among the six different agar media by the direct plating and IMS-plating methods. As a result, it was suggested that the following methods are adequate for detection of EHEC O111 in beef: combinations of enrichment in NmEC at 42 degrees C, and direct plating and IMS-plating methods, or LAMP assay as a screening assay to detect VT gene followed by direct plating and IMS-plating methods.