全膝关节置换术中计算机辅助髌骨切除术。

Q Medicine
C Fu, J Wai, E Lee, C Myden, E Batuyong, C R Hutchison, C Anglin
{"title":"全膝关节置换术中计算机辅助髌骨切除术。","authors":"C Fu,&nbsp;J Wai,&nbsp;E Lee,&nbsp;C Myden,&nbsp;E Batuyong,&nbsp;C R Hutchison,&nbsp;C Anglin","doi":"10.3109/10929088.2011.638399","DOIUrl":null,"url":null,"abstract":"<p><p>Incorrect patellar resection during total knee arthroplasty can lead to anterior knee pain, patellar maltracking, patellofemoral impingement, patellar fracture, component loosening and reduced range of motion. A computer-assisted surgery (CAS) system was developed to improve the accuracy of the patellar cut. Twelve cadaveric knee specimens (6 pairs) were surgically prepared and the patella resected by two senior orthopaedic residents using either a conventional sawguide technique (right knee) or a computer-assisted sawguide technique (left knee). Multiple cuts and measurements were permitted for the conventional technique, to reflect the clinical situation, whereas only a single cut was permitted for the CAS technique. Prior training had been provided on artificial bones for both techniques. Custom marker arrays were mounted on the sawguide and patella. The user positioned the sawguide based on a real-time display that compared the current sawguide plane to the ideal resection. The resulting mediolateral and superoinferior resection angles and central thickness were measured from CT scans of the specimens, relative to the anterior surface of the patella. Both techniques resulted in symmetric cuts (<7°). Repeatability in the mediolateral direction was better for the CAS technique than for the conventional technique (p<0.01). This study demonstrated that computer-assisted patellar resection is a feasible approach that can produce results equal to or better than those obtained with conventional techniques, even when the experimental conditions favor the conventional technique. Improvements in the CAS hardware could further improve the accuracy and usability of the system, resulting in reductions in postoperative complications. Patellar CAS could also serve as a valuable tool for feedback and training.</p>","PeriodicalId":50644,"journal":{"name":"Computer Aided Surgery","volume":"17 1","pages":"21-8"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10929088.2011.638399","citationCount":"7","resultStr":"{\"title\":\"Computer-assisted patellar resection for total knee arthroplasty.\",\"authors\":\"C Fu,&nbsp;J Wai,&nbsp;E Lee,&nbsp;C Myden,&nbsp;E Batuyong,&nbsp;C R Hutchison,&nbsp;C Anglin\",\"doi\":\"10.3109/10929088.2011.638399\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Incorrect patellar resection during total knee arthroplasty can lead to anterior knee pain, patellar maltracking, patellofemoral impingement, patellar fracture, component loosening and reduced range of motion. A computer-assisted surgery (CAS) system was developed to improve the accuracy of the patellar cut. Twelve cadaveric knee specimens (6 pairs) were surgically prepared and the patella resected by two senior orthopaedic residents using either a conventional sawguide technique (right knee) or a computer-assisted sawguide technique (left knee). Multiple cuts and measurements were permitted for the conventional technique, to reflect the clinical situation, whereas only a single cut was permitted for the CAS technique. Prior training had been provided on artificial bones for both techniques. Custom marker arrays were mounted on the sawguide and patella. The user positioned the sawguide based on a real-time display that compared the current sawguide plane to the ideal resection. The resulting mediolateral and superoinferior resection angles and central thickness were measured from CT scans of the specimens, relative to the anterior surface of the patella. Both techniques resulted in symmetric cuts (<7°). Repeatability in the mediolateral direction was better for the CAS technique than for the conventional technique (p<0.01). This study demonstrated that computer-assisted patellar resection is a feasible approach that can produce results equal to or better than those obtained with conventional techniques, even when the experimental conditions favor the conventional technique. Improvements in the CAS hardware could further improve the accuracy and usability of the system, resulting in reductions in postoperative complications. Patellar CAS could also serve as a valuable tool for feedback and training.</p>\",\"PeriodicalId\":50644,\"journal\":{\"name\":\"Computer Aided Surgery\",\"volume\":\"17 1\",\"pages\":\"21-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10929088.2011.638399\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Aided Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10929088.2011.638399\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Aided Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10929088.2011.638399","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 7

摘要

全膝关节置换术中不正确的髌骨切除可导致膝关节前侧疼痛、髌骨偏离、髌股撞击、髌骨骨折、部件松动和活动范围减小。计算机辅助手术(CAS)系统的开发,以提高准确性的髌骨切割。12个尸体膝关节标本(6对)手术准备,由两名高级骨科住院医师使用常规锯导技术(右膝)或计算机辅助锯导技术(左膝)切除髌骨。常规技术允许多次切割和测量,以反映临床情况,而CAS技术只允许一次切割。这两种技术之前都接受过人工骨的培训。定制标记阵列安装在锯导和髌骨上。用户根据实时显示来定位锯床,实时显示将当前的锯床平面与理想的切面进行比较。通过CT扫描测量标本相对于髌骨前表面的中外侧和上下方切除角度和中心厚度。这两种技术都产生了对称的切割(
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Computer-assisted patellar resection for total knee arthroplasty.

Incorrect patellar resection during total knee arthroplasty can lead to anterior knee pain, patellar maltracking, patellofemoral impingement, patellar fracture, component loosening and reduced range of motion. A computer-assisted surgery (CAS) system was developed to improve the accuracy of the patellar cut. Twelve cadaveric knee specimens (6 pairs) were surgically prepared and the patella resected by two senior orthopaedic residents using either a conventional sawguide technique (right knee) or a computer-assisted sawguide technique (left knee). Multiple cuts and measurements were permitted for the conventional technique, to reflect the clinical situation, whereas only a single cut was permitted for the CAS technique. Prior training had been provided on artificial bones for both techniques. Custom marker arrays were mounted on the sawguide and patella. The user positioned the sawguide based on a real-time display that compared the current sawguide plane to the ideal resection. The resulting mediolateral and superoinferior resection angles and central thickness were measured from CT scans of the specimens, relative to the anterior surface of the patella. Both techniques resulted in symmetric cuts (<7°). Repeatability in the mediolateral direction was better for the CAS technique than for the conventional technique (p<0.01). This study demonstrated that computer-assisted patellar resection is a feasible approach that can produce results equal to or better than those obtained with conventional techniques, even when the experimental conditions favor the conventional technique. Improvements in the CAS hardware could further improve the accuracy and usability of the system, resulting in reductions in postoperative complications. Patellar CAS could also serve as a valuable tool for feedback and training.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Computer Aided Surgery
Computer Aided Surgery 医学-外科
CiteScore
0.75
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊介绍: The scope of Computer Aided Surgery encompasses all fields within surgery, as well as biomedical imaging and instrumentation, and digital technology employed as an adjunct to imaging in diagnosis, therapeutics, and surgery. Topics featured include frameless as well as conventional stereotaxic procedures, surgery guided by ultrasound, image guided focal irradiation, robotic surgery, and other therapeutic interventions that are performed with the use of digital imaging technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信