Lokanath Garhnayak, Hari Parkash, D K Sehgal, Veena Jain, Mirna Garhnayak
{"title":"有卡环设计和无卡环设计的不同根管治疗后固位牙应力分布的比较研究--有限元分析。","authors":"Lokanath Garhnayak, Hari Parkash, D K Sehgal, Veena Jain, Mirna Garhnayak","doi":"10.5402/2011/102329","DOIUrl":null,"url":null,"abstract":"<p><p>Purpose. To analyze the stress distribution in an endodontically treated maxillary central incisor restored with various post-core systems and assess the benefit of ferrule using finite element analysis. Material and Methods. Twelve models with metal ceramic crown were created based on the combination of three types of post-core systems (titanium post-composite resin core, nickel-chromium post-core, and fiber reinforced composite resin post-composite resin core), two varieties of posts (tapered, parallel), and with or without ferrule. 100 N load was applied in three directions and the von Mises stress was compared. Results. Ferrule made no difference in stress distribution for the titanium and nickel-chromium posts, though it showed some stress reduction in fiber-reinforced composite resin posts. Nickel-chromium cast post-core transmitted the least amount of stresses to the dentin despite producing the maximum stress. Conclusion. Incorporation of ferrule offered some degree of stress reduction in nonmetal post, and it increased the stresses within cervical dentin.</p>","PeriodicalId":89396,"journal":{"name":"ISRN dentistry","volume":"2011 ","pages":"102329"},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3168916/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Comparative Study of the Stress Distribution in Different EndodonticPost-RetainedTeeth with and without Ferrule Design-A Finite Element Analysis.\",\"authors\":\"Lokanath Garhnayak, Hari Parkash, D K Sehgal, Veena Jain, Mirna Garhnayak\",\"doi\":\"10.5402/2011/102329\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Purpose. To analyze the stress distribution in an endodontically treated maxillary central incisor restored with various post-core systems and assess the benefit of ferrule using finite element analysis. Material and Methods. Twelve models with metal ceramic crown were created based on the combination of three types of post-core systems (titanium post-composite resin core, nickel-chromium post-core, and fiber reinforced composite resin post-composite resin core), two varieties of posts (tapered, parallel), and with or without ferrule. 100 N load was applied in three directions and the von Mises stress was compared. Results. Ferrule made no difference in stress distribution for the titanium and nickel-chromium posts, though it showed some stress reduction in fiber-reinforced composite resin posts. Nickel-chromium cast post-core transmitted the least amount of stresses to the dentin despite producing the maximum stress. Conclusion. Incorporation of ferrule offered some degree of stress reduction in nonmetal post, and it increased the stresses within cervical dentin.</p>\",\"PeriodicalId\":89396,\"journal\":{\"name\":\"ISRN dentistry\",\"volume\":\"2011 \",\"pages\":\"102329\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3168916/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISRN dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5402/2011/102329\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2011/6/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5402/2011/102329","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/6/14 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
目的使用有限元分析法分析经根管治疗后使用各种后牙髓系统修复的上颌中切牙的应力分布,并评估套圈的益处。材料和方法。根据三种后核系统(钛后核-复合树脂核、镍铬后核、纤维增强复合树脂后核-复合树脂核)、两种桩体(锥形桩体、平行桩体)以及有无套圈的组合,制作了 12 个金属烤瓷冠模型。在三个方向上施加 100 N 的荷载并比较 von Mises 应力。结果如下套圈对钛和镍铬基桩的应力分布没有影响,但对纤维增强复合树脂基桩的应力有一定影响。镍铬铸造后牙髓向牙本质传递的应力最小,尽管产生的应力最大。结论。在非金属桩中加入套圈可以在一定程度上减少应力,但会增加牙颈部牙本质内的应力。
A Comparative Study of the Stress Distribution in Different EndodonticPost-RetainedTeeth with and without Ferrule Design-A Finite Element Analysis.
Purpose. To analyze the stress distribution in an endodontically treated maxillary central incisor restored with various post-core systems and assess the benefit of ferrule using finite element analysis. Material and Methods. Twelve models with metal ceramic crown were created based on the combination of three types of post-core systems (titanium post-composite resin core, nickel-chromium post-core, and fiber reinforced composite resin post-composite resin core), two varieties of posts (tapered, parallel), and with or without ferrule. 100 N load was applied in three directions and the von Mises stress was compared. Results. Ferrule made no difference in stress distribution for the titanium and nickel-chromium posts, though it showed some stress reduction in fiber-reinforced composite resin posts. Nickel-chromium cast post-core transmitted the least amount of stresses to the dentin despite producing the maximum stress. Conclusion. Incorporation of ferrule offered some degree of stress reduction in nonmetal post, and it increased the stresses within cervical dentin.