highFO喷雾器治疗I型呼吸衰竭2例

Kei Nakashima, Nobuhiro Asai, Yoshihiro Ohkuni, Ryo Matsunuma, Takuya Iwasaki, Norihiro Kaneko
{"title":"highFO喷雾器治疗I型呼吸衰竭2例","authors":"Kei Nakashima,&nbsp;Nobuhiro Asai,&nbsp;Yoshihiro Ohkuni,&nbsp;Ryo Matsunuma,&nbsp;Takuya Iwasaki,&nbsp;Norihiro Kaneko","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Among conventional oxygen therapies there are currently no devices which can supply a high oxygen level of over 60%. The HighFO nebulizer (Koike Medical) is a new device which is able to supply an oxygen flow rate of over 35l/min, and a high concentration of oxygen. We report 2 cases of type I respiratory failure managed by the HighFO nebulizer. Case 1: A 70-year-old man with lung cancer had an acute exacerbation of radiation pneumonitis during chemoradiotherapy. We gave him an oxygen mask with a reserve bag, but his condition worsened. We then used the HighFO nebulizer followed by non-invasive positive pressure ventilation. He began to recover and we again used the HighFO nebulizer during the weaning period. Case 2: A 74-year-old man presented with acute exacerbation of interstitial pneumonitis. We started steroid pulse therapy, HighFO nebulizer treatment and physiotherapy to prevent disuse syndrome. We were able to raise his exercise stress levels due to the high concentration of oxygen provided by the HighFO nebulizer. We believe that the HighFO nebulizer is useful for type-I respiratory failure as well as interstitial pneumonia. However, oxygen toxicity is a potential problem, so we must accumulate more cases in order to fully assess the risks and benefits of this new modality.</p>","PeriodicalId":19218,"journal":{"name":"Nihon Kokyuki Gakkai zasshi = the journal of the Japanese Respiratory Society","volume":"49 7","pages":"511-6"},"PeriodicalIF":0.0000,"publicationDate":"2011-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Two cases of type I respiratory failure managed by the highFO nebulizer].\",\"authors\":\"Kei Nakashima,&nbsp;Nobuhiro Asai,&nbsp;Yoshihiro Ohkuni,&nbsp;Ryo Matsunuma,&nbsp;Takuya Iwasaki,&nbsp;Norihiro Kaneko\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Among conventional oxygen therapies there are currently no devices which can supply a high oxygen level of over 60%. The HighFO nebulizer (Koike Medical) is a new device which is able to supply an oxygen flow rate of over 35l/min, and a high concentration of oxygen. We report 2 cases of type I respiratory failure managed by the HighFO nebulizer. Case 1: A 70-year-old man with lung cancer had an acute exacerbation of radiation pneumonitis during chemoradiotherapy. We gave him an oxygen mask with a reserve bag, but his condition worsened. We then used the HighFO nebulizer followed by non-invasive positive pressure ventilation. He began to recover and we again used the HighFO nebulizer during the weaning period. Case 2: A 74-year-old man presented with acute exacerbation of interstitial pneumonitis. We started steroid pulse therapy, HighFO nebulizer treatment and physiotherapy to prevent disuse syndrome. We were able to raise his exercise stress levels due to the high concentration of oxygen provided by the HighFO nebulizer. We believe that the HighFO nebulizer is useful for type-I respiratory failure as well as interstitial pneumonia. However, oxygen toxicity is a potential problem, so we must accumulate more cases in order to fully assess the risks and benefits of this new modality.</p>\",\"PeriodicalId\":19218,\"journal\":{\"name\":\"Nihon Kokyuki Gakkai zasshi = the journal of the Japanese Respiratory Society\",\"volume\":\"49 7\",\"pages\":\"511-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nihon Kokyuki Gakkai zasshi = the journal of the Japanese Respiratory Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Kokyuki Gakkai zasshi = the journal of the Japanese Respiratory Society","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在传统的氧疗法中,目前还没有一种设备可以提供超过60%的高氧水平。HighFO喷雾器(小池医疗)是一种能够提供超过35l/min的氧气流量和高浓度氧气的新设备。我们报告2例I型呼吸衰竭管理的HighFO喷雾器。病例1:70岁男性肺癌患者放化疗期间放射性肺炎急性加重。我们给了他一个氧气面罩和一个备用袋,但他的情况恶化了。然后我们使用HighFO喷雾器,然后进行无创正压通气。他开始恢复,我们在断奶期间再次使用了HighFO喷雾器。病例2:一名74岁男性表现为间质性肺炎急性加重。我们开始类固醇脉冲治疗,HighFO喷雾器治疗和物理治疗,以防止废用综合征。由于HighFO喷雾器提供的高浓度氧气,我们能够提高他的运动压力水平。我们相信HighFO喷雾器对i型呼吸衰竭和间质性肺炎是有用的。然而,氧中毒是一个潜在的问题,因此我们必须积累更多的病例,以便充分评估这种新方式的风险和益处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Two cases of type I respiratory failure managed by the highFO nebulizer].

Among conventional oxygen therapies there are currently no devices which can supply a high oxygen level of over 60%. The HighFO nebulizer (Koike Medical) is a new device which is able to supply an oxygen flow rate of over 35l/min, and a high concentration of oxygen. We report 2 cases of type I respiratory failure managed by the HighFO nebulizer. Case 1: A 70-year-old man with lung cancer had an acute exacerbation of radiation pneumonitis during chemoradiotherapy. We gave him an oxygen mask with a reserve bag, but his condition worsened. We then used the HighFO nebulizer followed by non-invasive positive pressure ventilation. He began to recover and we again used the HighFO nebulizer during the weaning period. Case 2: A 74-year-old man presented with acute exacerbation of interstitial pneumonitis. We started steroid pulse therapy, HighFO nebulizer treatment and physiotherapy to prevent disuse syndrome. We were able to raise his exercise stress levels due to the high concentration of oxygen provided by the HighFO nebulizer. We believe that the HighFO nebulizer is useful for type-I respiratory failure as well as interstitial pneumonia. However, oxygen toxicity is a potential problem, so we must accumulate more cases in order to fully assess the risks and benefits of this new modality.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信