流感疫苗临床试验血清学的合作研究-第2部分:可重复性研究。

Q4 Medicine
Pharmeuropa bio & scientific notes Pub Date : 2011-06-01
J M Wood, E Montomoli, R W Newman, A Daas, K-H Buchheit, E Terao
{"title":"流感疫苗临床试验血清学的合作研究-第2部分:可重复性研究。","authors":"J M Wood,&nbsp;E Montomoli,&nbsp;R W Newman,&nbsp;A Daas,&nbsp;K-H Buchheit,&nbsp;E Terao","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A collaborative study was run by the Biological Standardisation Programme (BSP) under the aegis of the European Directorate for the Quality of Medicines & HealthCare (EDQM, Council of Europe) and the European Union (EU) Commission, to address the issue of the poor standardisation of serological assays used for the evaluation of seasonal influenza vaccines in Europe. The Phase 1 of the study focused on the compliance to Committee for Human Medicinal Products (CHMP) criteria by 6 manufacturers and 5 public laboratories. It confirmed the poor inter-laboratory correlation of haemagglutination inhibition (HI) test results. Phase 2 consisted in a reproducibility study examining the impact of extended method standardisation and the use of reference sera on inter-laboratory variation. Six manufacturers and 5 public laboratories contributed HI results, while the 5 public laboratories also performed single radial haemolysis (SRH) tests on the same sample panels. Results showed that method standardisation failed to significantly improve the inter-laboratory variation. Correction for pre-vaccination titres (Beyer correction) was found to have limited effect to improve the bias constituted by the Protection Rate (PR) criterion. The reasons underlying the difficulty in standardisation of HI and SRH tests are discussed and improved approaches for the compliance testing to CHMP criteria are suggested.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2011 1","pages":"36-54"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Collaborative study on influenza vaccine clinical trial serology - part 2: reproducibility study.\",\"authors\":\"J M Wood,&nbsp;E Montomoli,&nbsp;R W Newman,&nbsp;A Daas,&nbsp;K-H Buchheit,&nbsp;E Terao\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A collaborative study was run by the Biological Standardisation Programme (BSP) under the aegis of the European Directorate for the Quality of Medicines & HealthCare (EDQM, Council of Europe) and the European Union (EU) Commission, to address the issue of the poor standardisation of serological assays used for the evaluation of seasonal influenza vaccines in Europe. The Phase 1 of the study focused on the compliance to Committee for Human Medicinal Products (CHMP) criteria by 6 manufacturers and 5 public laboratories. It confirmed the poor inter-laboratory correlation of haemagglutination inhibition (HI) test results. Phase 2 consisted in a reproducibility study examining the impact of extended method standardisation and the use of reference sera on inter-laboratory variation. Six manufacturers and 5 public laboratories contributed HI results, while the 5 public laboratories also performed single radial haemolysis (SRH) tests on the same sample panels. Results showed that method standardisation failed to significantly improve the inter-laboratory variation. Correction for pre-vaccination titres (Beyer correction) was found to have limited effect to improve the bias constituted by the Protection Rate (PR) criterion. The reasons underlying the difficulty in standardisation of HI and SRH tests are discussed and improved approaches for the compliance testing to CHMP criteria are suggested.</p>\",\"PeriodicalId\":39192,\"journal\":{\"name\":\"Pharmeuropa bio & scientific notes\",\"volume\":\"2011 1\",\"pages\":\"36-54\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmeuropa bio & scientific notes\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmeuropa bio & scientific notes","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

在欧洲药品和保健质量理事会(EDQM)和欧洲联盟(EU)委员会的支持下,生物标准化规划(BSP)开展了一项合作研究,以解决欧洲用于评估季节性流感疫苗的血清学分析标准化不高的问题。该研究的第一阶段侧重于6家制造商和5家公共实验室对人用药品委员会(CHMP)标准的遵守情况。它证实了血凝抑制(HI)试验结果的实验室间相关性较差。第二阶段包括一项可重复性研究,检查扩展方法标准化和参考血清使用对实验室间差异的影响。6家制造商和5个公共实验室提供了溶血化验结果,而这5个公共实验室还对同一样品板进行单一放射状溶血化验。结果表明,方法标准化未能显著改善实验室间差异。对疫苗接种前滴度的校正(Beyer校正)对改善由保护率(PR)标准构成的偏倚效果有限。讨论了HI和SRH测试难以标准化的原因,并提出了改进CHMP标准符合性测试的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Collaborative study on influenza vaccine clinical trial serology - part 2: reproducibility study.

A collaborative study was run by the Biological Standardisation Programme (BSP) under the aegis of the European Directorate for the Quality of Medicines & HealthCare (EDQM, Council of Europe) and the European Union (EU) Commission, to address the issue of the poor standardisation of serological assays used for the evaluation of seasonal influenza vaccines in Europe. The Phase 1 of the study focused on the compliance to Committee for Human Medicinal Products (CHMP) criteria by 6 manufacturers and 5 public laboratories. It confirmed the poor inter-laboratory correlation of haemagglutination inhibition (HI) test results. Phase 2 consisted in a reproducibility study examining the impact of extended method standardisation and the use of reference sera on inter-laboratory variation. Six manufacturers and 5 public laboratories contributed HI results, while the 5 public laboratories also performed single radial haemolysis (SRH) tests on the same sample panels. Results showed that method standardisation failed to significantly improve the inter-laboratory variation. Correction for pre-vaccination titres (Beyer correction) was found to have limited effect to improve the bias constituted by the Protection Rate (PR) criterion. The reasons underlying the difficulty in standardisation of HI and SRH tests are discussed and improved approaches for the compliance testing to CHMP criteria are suggested.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pharmeuropa bio & scientific notes
Pharmeuropa bio & scientific notes Medicine-Medicine (all)
CiteScore
0.70
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信