B X He, L Shi, J Qiu, X H Zeng, L Tao, R Li, C J Hong, X L Gu, F Y Dong, L Yang, S J Zhao
{"title":"液相色谱串联质谱法和药代动力学评价定量测定人血浆中阿托伐他汀和正羟基阿托伐他汀。","authors":"B X He, L Shi, J Qiu, X H Zeng, L Tao, R Li, C J Hong, X L Gu, F Y Dong, L Yang, S J Zhao","doi":"10.1358/mf.2010.32.7.1487086","DOIUrl":null,"url":null,"abstract":"<p><p>A specific, sensitive and simple method was developed to determine the levels of both atorvastatin and ortho-hydroxy atorvastatin in human plasma. The analytes and internal standard pitavastatin were extracted from plasma by liquid-liquid extraction, separated on a Zorbax SB-C18 column, eluted with a mobile phase of water:acetonitrile (45:55 v/v), both containing 5% methanol and 0.01% formic acid. Detection was performed with an electrospray ionization triple quadrupole mass spectrometer in positive ion mode using multiple reaction monitoring. The standard calibration curves of atorvastatin and ortho-hydroxy atorvastatin were linear in the concentration range of 0.2-20 and 0.1-20 ng/mL, respectively. The intra- and inter-day precisions were < 7.7% and the accuracy was within ± 5.9%. The method has been successfully used for the study of the pharmacokinetics of atorvastatin and ortho-hydroxy atorvastatin in Chinese patients with coronary heart disease after a single oral dose of 20 mg atorvastatin. The mean values for the area under the plasma concentration-time curve for atorvastatin and ortho-hydroxy atorvastatin were 63.1 and 46.9 ng.h/mL, respectively.</p>","PeriodicalId":18443,"journal":{"name":"Methods and findings in experimental and clinical pharmacology","volume":"32 7","pages":"481-7"},"PeriodicalIF":0.0000,"publicationDate":"2010-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Quantitative determination of atorvastatin and ortho-hydroxy atorvastatin in human plasma by liquid chromatography tandem mass spectrometry and pharmacokinetic evaluation.\",\"authors\":\"B X He, L Shi, J Qiu, X H Zeng, L Tao, R Li, C J Hong, X L Gu, F Y Dong, L Yang, S J Zhao\",\"doi\":\"10.1358/mf.2010.32.7.1487086\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A specific, sensitive and simple method was developed to determine the levels of both atorvastatin and ortho-hydroxy atorvastatin in human plasma. The analytes and internal standard pitavastatin were extracted from plasma by liquid-liquid extraction, separated on a Zorbax SB-C18 column, eluted with a mobile phase of water:acetonitrile (45:55 v/v), both containing 5% methanol and 0.01% formic acid. Detection was performed with an electrospray ionization triple quadrupole mass spectrometer in positive ion mode using multiple reaction monitoring. The standard calibration curves of atorvastatin and ortho-hydroxy atorvastatin were linear in the concentration range of 0.2-20 and 0.1-20 ng/mL, respectively. The intra- and inter-day precisions were < 7.7% and the accuracy was within ± 5.9%. The method has been successfully used for the study of the pharmacokinetics of atorvastatin and ortho-hydroxy atorvastatin in Chinese patients with coronary heart disease after a single oral dose of 20 mg atorvastatin. The mean values for the area under the plasma concentration-time curve for atorvastatin and ortho-hydroxy atorvastatin were 63.1 and 46.9 ng.h/mL, respectively.</p>\",\"PeriodicalId\":18443,\"journal\":{\"name\":\"Methods and findings in experimental and clinical pharmacology\",\"volume\":\"32 7\",\"pages\":\"481-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Methods and findings in experimental and clinical pharmacology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1358/mf.2010.32.7.1487086\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and findings in experimental and clinical pharmacology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1358/mf.2010.32.7.1487086","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Quantitative determination of atorvastatin and ortho-hydroxy atorvastatin in human plasma by liquid chromatography tandem mass spectrometry and pharmacokinetic evaluation.
A specific, sensitive and simple method was developed to determine the levels of both atorvastatin and ortho-hydroxy atorvastatin in human plasma. The analytes and internal standard pitavastatin were extracted from plasma by liquid-liquid extraction, separated on a Zorbax SB-C18 column, eluted with a mobile phase of water:acetonitrile (45:55 v/v), both containing 5% methanol and 0.01% formic acid. Detection was performed with an electrospray ionization triple quadrupole mass spectrometer in positive ion mode using multiple reaction monitoring. The standard calibration curves of atorvastatin and ortho-hydroxy atorvastatin were linear in the concentration range of 0.2-20 and 0.1-20 ng/mL, respectively. The intra- and inter-day precisions were < 7.7% and the accuracy was within ± 5.9%. The method has been successfully used for the study of the pharmacokinetics of atorvastatin and ortho-hydroxy atorvastatin in Chinese patients with coronary heart disease after a single oral dose of 20 mg atorvastatin. The mean values for the area under the plasma concentration-time curve for atorvastatin and ortho-hydroxy atorvastatin were 63.1 and 46.9 ng.h/mL, respectively.