Marie-Christine Wagnon, Astrid Scharpantgen, Carlo Back, Danielle Hansen-Koenig
{"title":"卢森堡大公国的病人安全和乳房x光检查项目:乳房x光检查发现的癌症的护理。回顾性研究)。","authors":"Marie-Christine Wagnon, Astrid Scharpantgen, Carlo Back, Danielle Hansen-Koenig","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Unlabelled: </strong>In Luxemburg, the national breast cancer mammography screening programme has been running for 18 years. The Coordinating Centre treats approximately 17,000 files a year. The Health Directorate, as promoter of the \"Programme Mammographie\", is obliged to provide itself with a maximum of guarantees; within the framework of its legal missions, it has to implement all the possible means in order that the whole approach assures minimal adverse effects. The technical quality of the 9 centres is at the level required by the European Guidelines for Quality Assurance in Mammography Screening and Diagnosis, 4th edition. The quality of the readings was already the subject of 2 evaluations of the performance of the readers: the mean accuracy of the first readers to detect cancers is 87%, of the second readers 97%. The mean recall rate for assessment is about 6%. The double reading assures the detection of between 15 and 21% additional cancers, depending on the years. The imaging of diagnostic assessment has been the subject of a retrospective study. Out of 392 cancers, time from assessment to diagnosis was longer then 24 months for 17 women (4%). Examples are described and reasons for negative assessment are listed. The main cause is the multiplicity of the doctors acting in the assessment process, resulting in a default of the examination synthesis and a certain lack of communication and multidisciplinary approach. More convergence in diagnostic breast assessment and a shortening of delays between screening and diagnosis, are desirable.</p><p><strong>In conclusion: </strong>The evolution towards Specialist Centres for breast cancer care answers an ethical obligation which the initiators of a public health programme have to assume, such as the organization of a high quality breast cancer screening programme.</p>","PeriodicalId":72476,"journal":{"name":"Bulletin de la Societe des sciences medicales du Grand-Duche de Luxembourg","volume":" 2","pages":"303-13"},"PeriodicalIF":0.0000,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Safety of the patient and the Mammography Program in the Grand Duchy of Luxembourg: Care of cancers detected by mammography. Retrospective studies].\",\"authors\":\"Marie-Christine Wagnon, Astrid Scharpantgen, Carlo Back, Danielle Hansen-Koenig\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Unlabelled: </strong>In Luxemburg, the national breast cancer mammography screening programme has been running for 18 years. The Coordinating Centre treats approximately 17,000 files a year. The Health Directorate, as promoter of the \\\"Programme Mammographie\\\", is obliged to provide itself with a maximum of guarantees; within the framework of its legal missions, it has to implement all the possible means in order that the whole approach assures minimal adverse effects. The technical quality of the 9 centres is at the level required by the European Guidelines for Quality Assurance in Mammography Screening and Diagnosis, 4th edition. The quality of the readings was already the subject of 2 evaluations of the performance of the readers: the mean accuracy of the first readers to detect cancers is 87%, of the second readers 97%. The mean recall rate for assessment is about 6%. The double reading assures the detection of between 15 and 21% additional cancers, depending on the years. The imaging of diagnostic assessment has been the subject of a retrospective study. Out of 392 cancers, time from assessment to diagnosis was longer then 24 months for 17 women (4%). Examples are described and reasons for negative assessment are listed. The main cause is the multiplicity of the doctors acting in the assessment process, resulting in a default of the examination synthesis and a certain lack of communication and multidisciplinary approach. More convergence in diagnostic breast assessment and a shortening of delays between screening and diagnosis, are desirable.</p><p><strong>In conclusion: </strong>The evolution towards Specialist Centres for breast cancer care answers an ethical obligation which the initiators of a public health programme have to assume, such as the organization of a high quality breast cancer screening programme.</p>\",\"PeriodicalId\":72476,\"journal\":{\"name\":\"Bulletin de la Societe des sciences medicales du Grand-Duche de Luxembourg\",\"volume\":\" 2\",\"pages\":\"303-13\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin de la Societe des sciences medicales du Grand-Duche de Luxembourg\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin de la Societe des sciences medicales du Grand-Duche de Luxembourg","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Safety of the patient and the Mammography Program in the Grand Duchy of Luxembourg: Care of cancers detected by mammography. Retrospective studies].
Unlabelled: In Luxemburg, the national breast cancer mammography screening programme has been running for 18 years. The Coordinating Centre treats approximately 17,000 files a year. The Health Directorate, as promoter of the "Programme Mammographie", is obliged to provide itself with a maximum of guarantees; within the framework of its legal missions, it has to implement all the possible means in order that the whole approach assures minimal adverse effects. The technical quality of the 9 centres is at the level required by the European Guidelines for Quality Assurance in Mammography Screening and Diagnosis, 4th edition. The quality of the readings was already the subject of 2 evaluations of the performance of the readers: the mean accuracy of the first readers to detect cancers is 87%, of the second readers 97%. The mean recall rate for assessment is about 6%. The double reading assures the detection of between 15 and 21% additional cancers, depending on the years. The imaging of diagnostic assessment has been the subject of a retrospective study. Out of 392 cancers, time from assessment to diagnosis was longer then 24 months for 17 women (4%). Examples are described and reasons for negative assessment are listed. The main cause is the multiplicity of the doctors acting in the assessment process, resulting in a default of the examination synthesis and a certain lack of communication and multidisciplinary approach. More convergence in diagnostic breast assessment and a shortening of delays between screening and diagnosis, are desirable.
In conclusion: The evolution towards Specialist Centres for breast cancer care answers an ethical obligation which the initiators of a public health programme have to assume, such as the organization of a high quality breast cancer screening programme.