Liusheng Huang, Patricia S Lizak, Anura L Jayewardene, Florence Marzan, Ming-Na Tina Lee, Francesca T Aweeka
{"title":"改进的高效液相色谱-紫外法结合蛋白沉淀和固相萃取法测定人血浆中氟苯胍的方法:应用于药代动力学研究。","authors":"Liusheng Huang, Patricia S Lizak, Anura L Jayewardene, Florence Marzan, Ming-Na Tina Lee, Francesca T Aweeka","doi":"10.4137/aci.s4431","DOIUrl":null,"url":null,"abstract":"<p><p>An HPLC-UV method was developed and validated for the determination of lumefantrine in human plasma. Lumefantrine and its internal standard halofantrine were extracted from plasma samples using protein precipitation with acetonitrile (0.2% perchloric acid) followed by solid-phase extraction with Hypersep C(8) cartridges. Chromatographic separation was performed on a Zorbax SB-CN HPLC column (3.0 x 150 mm, 3.5 microm) with water/methanol (0.1% TFA) as the mobile phases in a gradient elution mode. Detection was performed using UV/vis detector at lambda = 335 nm. The method showed to be linear over a range of 50-10,000 ng/mL with acceptable intra- and inter-day precision and accuracy. The mean recoveries were 88.2% for lumefatrine and 84.5% for the I.S. The internal standard halofantrine is readily available from commercial sources. This method was successfully applied to a pharmacokinetic interaction study between a first-line antimalarial combination (artemether-lumefantrine) and antiretroviral therapy.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"5 ","pages":"15-23"},"PeriodicalIF":0.0000,"publicationDate":"2010-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2865164/pdf/","citationCount":"0","resultStr":"{\"title\":\"A modified method for determination of lumefantrine in human plasma by HPLC-UV and combination of protein precipitation and solid-phase extraction: application to a pharmacokinetic study.\",\"authors\":\"Liusheng Huang, Patricia S Lizak, Anura L Jayewardene, Florence Marzan, Ming-Na Tina Lee, Francesca T Aweeka\",\"doi\":\"10.4137/aci.s4431\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An HPLC-UV method was developed and validated for the determination of lumefantrine in human plasma. Lumefantrine and its internal standard halofantrine were extracted from plasma samples using protein precipitation with acetonitrile (0.2% perchloric acid) followed by solid-phase extraction with Hypersep C(8) cartridges. Chromatographic separation was performed on a Zorbax SB-CN HPLC column (3.0 x 150 mm, 3.5 microm) with water/methanol (0.1% TFA) as the mobile phases in a gradient elution mode. Detection was performed using UV/vis detector at lambda = 335 nm. The method showed to be linear over a range of 50-10,000 ng/mL with acceptable intra- and inter-day precision and accuracy. The mean recoveries were 88.2% for lumefatrine and 84.5% for the I.S. The internal standard halofantrine is readily available from commercial sources. This method was successfully applied to a pharmacokinetic interaction study between a first-line antimalarial combination (artemether-lumefantrine) and antiretroviral therapy.</p>\",\"PeriodicalId\":7781,\"journal\":{\"name\":\"Analytical Chemistry Insights\",\"volume\":\"5 \",\"pages\":\"15-23\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-03-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2865164/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Chemistry Insights\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4137/aci.s4431\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry Insights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4137/aci.s4431","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A modified method for determination of lumefantrine in human plasma by HPLC-UV and combination of protein precipitation and solid-phase extraction: application to a pharmacokinetic study.
An HPLC-UV method was developed and validated for the determination of lumefantrine in human plasma. Lumefantrine and its internal standard halofantrine were extracted from plasma samples using protein precipitation with acetonitrile (0.2% perchloric acid) followed by solid-phase extraction with Hypersep C(8) cartridges. Chromatographic separation was performed on a Zorbax SB-CN HPLC column (3.0 x 150 mm, 3.5 microm) with water/methanol (0.1% TFA) as the mobile phases in a gradient elution mode. Detection was performed using UV/vis detector at lambda = 335 nm. The method showed to be linear over a range of 50-10,000 ng/mL with acceptable intra- and inter-day precision and accuracy. The mean recoveries were 88.2% for lumefatrine and 84.5% for the I.S. The internal standard halofantrine is readily available from commercial sources. This method was successfully applied to a pharmacokinetic interaction study between a first-line antimalarial combination (artemether-lumefantrine) and antiretroviral therapy.