{"title":"站立和行走的动力膝关节和踝关节假体的实时步态模式意图识别。","authors":"Huseyin Atakan Varol, Frank Sup, Michael Goldfarb","doi":"10.1109/BIOROB.2008.4762860","DOIUrl":null,"url":null,"abstract":"<p><p>This paper describes a real-time gait mode intent recognition approach for the supervisory control of a powered transfemoral prosthesis. The proposed approach infers user intent by recognizing patterns in the prosthesis sensor's signals in real-time, eliminating the need for sound-side instrumentation and allowing fast mode switching. Simple time based features extracted from frames of prosthesis signals are reduced to lower dimensions. Gaussian Mixture Models are trained using an experimental database for gait mode classification. A voting scheme is applied as a post-processing step to increase the robustness of decision making. The effectiveness of the proposed method is shown via gait experiments on a treadmill with a healthy subject using an able bodied adapter.</p>","PeriodicalId":74522,"journal":{"name":"Proceedings of the ... IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics. IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics","volume":"2008 ","pages":"66-72"},"PeriodicalIF":0.0000,"publicationDate":"2009-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/BIOROB.2008.4762860","citationCount":"53","resultStr":"{\"title\":\"Real-time Gait Mode Intent Recognition of a Powered Knee and Ankle Prosthesis for Standing and Walking.\",\"authors\":\"Huseyin Atakan Varol, Frank Sup, Michael Goldfarb\",\"doi\":\"10.1109/BIOROB.2008.4762860\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper describes a real-time gait mode intent recognition approach for the supervisory control of a powered transfemoral prosthesis. The proposed approach infers user intent by recognizing patterns in the prosthesis sensor's signals in real-time, eliminating the need for sound-side instrumentation and allowing fast mode switching. Simple time based features extracted from frames of prosthesis signals are reduced to lower dimensions. Gaussian Mixture Models are trained using an experimental database for gait mode classification. A voting scheme is applied as a post-processing step to increase the robustness of decision making. The effectiveness of the proposed method is shown via gait experiments on a treadmill with a healthy subject using an able bodied adapter.</p>\",\"PeriodicalId\":74522,\"journal\":{\"name\":\"Proceedings of the ... IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics. IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics\",\"volume\":\"2008 \",\"pages\":\"66-72\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-01-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/BIOROB.2008.4762860\",\"citationCount\":\"53\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the ... IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics. IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOROB.2008.4762860\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the ... IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics. IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOROB.2008.4762860","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Real-time Gait Mode Intent Recognition of a Powered Knee and Ankle Prosthesis for Standing and Walking.
This paper describes a real-time gait mode intent recognition approach for the supervisory control of a powered transfemoral prosthesis. The proposed approach infers user intent by recognizing patterns in the prosthesis sensor's signals in real-time, eliminating the need for sound-side instrumentation and allowing fast mode switching. Simple time based features extracted from frames of prosthesis signals are reduced to lower dimensions. Gaussian Mixture Models are trained using an experimental database for gait mode classification. A voting scheme is applied as a post-processing step to increase the robustness of decision making. The effectiveness of the proposed method is shown via gait experiments on a treadmill with a healthy subject using an able bodied adapter.