{"title":"NexGen LPS旋转平台全膝关节置换术:一项前瞻性研究的中期结果","authors":"Roberto Rossi,&nbsp;Andrea Ferro,&nbsp;Matteo Bruzzone,&nbsp;Davide Edoardo Bonasia,&nbsp;Giacomo Garzaro,&nbsp;Filippo Castoldi","doi":"10.1007/s12306-009-0027-1","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study is to present midterm results of NexGen LPS (Zimmer, Warsaw) rotating platform total knee arthroplasty. A prospective consecutive series of 50 primary rotating platform total knee replacements in 43 patients were clinically and radiographically evaluated at a mean follow-up of 46.4 (range 30-78) months. There were 12 men (30%) and 31 women (70%) with an average age of 72.3 years (range 55-85). All implants were cruciate-substituting and cemented. Patients were assessed using the Knee Society Clinical Rating System and the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. Pre-operatively, the mean knee score was 50.7 points (SD 15.1) and the mean function score was 40.5 points (SD 22.7). Post-operatively the mean knee score was 91.6 (SD 6.5) and the mean function score was 85.9 (SD 17.4). No sign of component loosening or osteolysis could be identified. The NexGen LPS rotating platform total knee replacement design provided excellent mid-term clinical and radiographical results.</p>","PeriodicalId":76085,"journal":{"name":"La Chirurgia degli organi di movimento","volume":"93 2","pages":"65-70"},"PeriodicalIF":0.0000,"publicationDate":"2009-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s12306-009-0027-1","citationCount":"9","resultStr":"{\"title\":\"NexGen LPS rotating platform total knee arthroplasty: medium-term results of a prospective study.\",\"authors\":\"Roberto Rossi,&nbsp;Andrea Ferro,&nbsp;Matteo Bruzzone,&nbsp;Davide Edoardo Bonasia,&nbsp;Giacomo Garzaro,&nbsp;Filippo Castoldi\",\"doi\":\"10.1007/s12306-009-0027-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study is to present midterm results of NexGen LPS (Zimmer, Warsaw) rotating platform total knee arthroplasty. A prospective consecutive series of 50 primary rotating platform total knee replacements in 43 patients were clinically and radiographically evaluated at a mean follow-up of 46.4 (range 30-78) months. There were 12 men (30%) and 31 women (70%) with an average age of 72.3 years (range 55-85). All implants were cruciate-substituting and cemented. Patients were assessed using the Knee Society Clinical Rating System and the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. Pre-operatively, the mean knee score was 50.7 points (SD 15.1) and the mean function score was 40.5 points (SD 22.7). Post-operatively the mean knee score was 91.6 (SD 6.5) and the mean function score was 85.9 (SD 17.4). No sign of component loosening or osteolysis could be identified. The NexGen LPS rotating platform total knee replacement design provided excellent mid-term clinical and radiographical results.</p>\",\"PeriodicalId\":76085,\"journal\":{\"name\":\"La Chirurgia degli organi di movimento\",\"volume\":\"93 2\",\"pages\":\"65-70\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s12306-009-0027-1\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"La Chirurgia degli organi di movimento\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s12306-009-0027-1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2009/4/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"La Chirurgia degli organi di movimento","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12306-009-0027-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2009/4/29 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本研究的目的是介绍NexGen LPS (Zimmer, Warsaw)旋转平台全膝关节置换术的中期结果。在平均46.4(30-78)个月的随访期间,对43例患者的50例原发性旋转平台全膝关节置换术进行了临床和影像学评估。男性12人(30%),女性31人(70%),平均年龄72.3岁(55-85岁)。所有种植体均采用十字骨置换和骨水泥。采用膝关节学会临床评分系统和膝关节学会全膝关节置换术x线评估评分系统对患者进行评估。术前膝关节评分平均为50.7分(SD 15.1),功能评分平均为40.5分(SD 22.7)。术后平均膝关节评分为91.6 (SD 6.5),平均功能评分为85.9 (SD 17.4)。没有发现构件松动或骨溶解的迹象。NexGen LPS旋转平台全膝关节置换术设计提供了良好的中期临床和影像学结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
NexGen LPS rotating platform total knee arthroplasty: medium-term results of a prospective study.

The purpose of this study is to present midterm results of NexGen LPS (Zimmer, Warsaw) rotating platform total knee arthroplasty. A prospective consecutive series of 50 primary rotating platform total knee replacements in 43 patients were clinically and radiographically evaluated at a mean follow-up of 46.4 (range 30-78) months. There were 12 men (30%) and 31 women (70%) with an average age of 72.3 years (range 55-85). All implants were cruciate-substituting and cemented. Patients were assessed using the Knee Society Clinical Rating System and the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. Pre-operatively, the mean knee score was 50.7 points (SD 15.1) and the mean function score was 40.5 points (SD 22.7). Post-operatively the mean knee score was 91.6 (SD 6.5) and the mean function score was 85.9 (SD 17.4). No sign of component loosening or osteolysis could be identified. The NexGen LPS rotating platform total knee replacement design provided excellent mid-term clinical and radiographical results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信