非法拉第电化学阻抗法分析降钙素原和c反应蛋白作为早期败血症检测的双标记生物传感器

IF 2.5 Q1 Chemistry
Ambalika Sanjeev Tanak , Badrinath Jagannath , Yashaswee Tamrakar , Sriram Muthukumar , Shalini Prasad
{"title":"非法拉第电化学阻抗法分析降钙素原和c反应蛋白作为早期败血症检测的双标记生物传感器","authors":"Ambalika Sanjeev Tanak ,&nbsp;Badrinath Jagannath ,&nbsp;Yashaswee Tamrakar ,&nbsp;Sriram Muthukumar ,&nbsp;Shalini Prasad","doi":"10.1016/j.acax.2019.100029","DOIUrl":null,"url":null,"abstract":"<div><p>In this work, we demonstrate a robust, dual marker, biosensing strategy for specific and sensitive electrochemical response of Procalcitonin and C-reactive protein in complex body fluids such as human serum and whole blood for the detection of sepsis. Enhanced sensitivity is achieved by leveraging the physicochemical properties of zinc oxide at the electrode-solution interface. Characterization techniques such as SEM, EDAX, AFM, FTIR and fluorescence microscopy were performed to ensure a suitable biosensing surface. The characteristic biomolecular interactions between the target analyte and specific capture probe is quantified through unique frequency signatures using non-faradaic electrochemical impedance spectroscopy (EIS). The developed biosensor demonstrated a detection limit of 0.10 ng mL<sup>−1</sup> for PCT in human serum and whole blood with an R<sup>2</sup> of 0.99 and 0.98 respectively. CRP demonstrated a detection limit of 0.10 μg mL<sup>−1</sup> in human serum and whole blood with an R<sup>2</sup> of 0.90 and 0.98 respectively. Cross-reactivity analysis demonstrated robust selectivity to PCT and CRP with negligible interaction to non-specific biomolecules. The novel aspect of this technology is the ability to fine-tune individual biomarkers response owing to the optimal frequency tuning capability. The developed biosensor requires an ultra-low sample volume of 10 μL without the need for sample dilution for rapid analysis. We envision the developed dual marker biosensor to be useful as a sepsis-screening device for prognostic monitoring.</p></div>","PeriodicalId":241,"journal":{"name":"Analytica Chimica Acta: X","volume":"3 ","pages":"Article 100029"},"PeriodicalIF":2.5000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.acax.2019.100029","citationCount":"65","resultStr":"{\"title\":\"Non-faradaic electrochemical impedimetric profiling of procalcitonin and C-reactive protein as a dual marker biosensor for early sepsis detection\",\"authors\":\"Ambalika Sanjeev Tanak ,&nbsp;Badrinath Jagannath ,&nbsp;Yashaswee Tamrakar ,&nbsp;Sriram Muthukumar ,&nbsp;Shalini Prasad\",\"doi\":\"10.1016/j.acax.2019.100029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this work, we demonstrate a robust, dual marker, biosensing strategy for specific and sensitive electrochemical response of Procalcitonin and C-reactive protein in complex body fluids such as human serum and whole blood for the detection of sepsis. Enhanced sensitivity is achieved by leveraging the physicochemical properties of zinc oxide at the electrode-solution interface. Characterization techniques such as SEM, EDAX, AFM, FTIR and fluorescence microscopy were performed to ensure a suitable biosensing surface. The characteristic biomolecular interactions between the target analyte and specific capture probe is quantified through unique frequency signatures using non-faradaic electrochemical impedance spectroscopy (EIS). The developed biosensor demonstrated a detection limit of 0.10 ng mL<sup>−1</sup> for PCT in human serum and whole blood with an R<sup>2</sup> of 0.99 and 0.98 respectively. CRP demonstrated a detection limit of 0.10 μg mL<sup>−1</sup> in human serum and whole blood with an R<sup>2</sup> of 0.90 and 0.98 respectively. Cross-reactivity analysis demonstrated robust selectivity to PCT and CRP with negligible interaction to non-specific biomolecules. The novel aspect of this technology is the ability to fine-tune individual biomarkers response owing to the optimal frequency tuning capability. The developed biosensor requires an ultra-low sample volume of 10 μL without the need for sample dilution for rapid analysis. We envision the developed dual marker biosensor to be useful as a sepsis-screening device for prognostic monitoring.</p></div>\",\"PeriodicalId\":241,\"journal\":{\"name\":\"Analytica Chimica Acta: X\",\"volume\":\"3 \",\"pages\":\"Article 100029\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.acax.2019.100029\",\"citationCount\":\"65\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytica Chimica Acta: X\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2590134619300258\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590134619300258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 65

摘要

在这项工作中,我们展示了一种强大的、双标记的生物传感策略,用于检测复杂体液(如人血清和全血)中降钙素原和c反应蛋白的特异性和敏感的电化学反应。通过利用氧化锌在电极-溶液界面处的物理化学性质来提高灵敏度。采用SEM, EDAX, AFM, FTIR和荧光显微镜等表征技术来确保合适的生物传感表面。使用非法拉第电化学阻抗谱(EIS)通过独特的频率特征来量化目标分析物与特定捕获探针之间的特征生物分子相互作用。该传感器对人血清和全血PCT的检出限为0.10 ng mL−1,R2分别为0.99和0.98。CRP在人血清和全血中的检出限为0.10 μg mL−1,R2分别为0.90和0.98。交叉反应性分析显示对PCT和CRP有很强的选择性,与非特异性生物分子的相互作用可以忽略不计。该技术的新颖之处在于,由于最佳的频率调谐能力,它能够微调个体生物标志物的反应。开发的生物传感器需要10 μL的超低样本量,无需样品稀释即可进行快速分析。我们设想开发的双标记生物传感器可作为脓毒症筛查设备用于预后监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Non-faradaic electrochemical impedimetric profiling of procalcitonin and C-reactive protein as a dual marker biosensor for early sepsis detection

Non-faradaic electrochemical impedimetric profiling of procalcitonin and C-reactive protein as a dual marker biosensor for early sepsis detection

In this work, we demonstrate a robust, dual marker, biosensing strategy for specific and sensitive electrochemical response of Procalcitonin and C-reactive protein in complex body fluids such as human serum and whole blood for the detection of sepsis. Enhanced sensitivity is achieved by leveraging the physicochemical properties of zinc oxide at the electrode-solution interface. Characterization techniques such as SEM, EDAX, AFM, FTIR and fluorescence microscopy were performed to ensure a suitable biosensing surface. The characteristic biomolecular interactions between the target analyte and specific capture probe is quantified through unique frequency signatures using non-faradaic electrochemical impedance spectroscopy (EIS). The developed biosensor demonstrated a detection limit of 0.10 ng mL−1 for PCT in human serum and whole blood with an R2 of 0.99 and 0.98 respectively. CRP demonstrated a detection limit of 0.10 μg mL−1 in human serum and whole blood with an R2 of 0.90 and 0.98 respectively. Cross-reactivity analysis demonstrated robust selectivity to PCT and CRP with negligible interaction to non-specific biomolecules. The novel aspect of this technology is the ability to fine-tune individual biomarkers response owing to the optimal frequency tuning capability. The developed biosensor requires an ultra-low sample volume of 10 μL without the need for sample dilution for rapid analysis. We envision the developed dual marker biosensor to be useful as a sepsis-screening device for prognostic monitoring.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytica Chimica Acta: X
Analytica Chimica Acta: X Chemistry-Analytical Chemistry
自引率
0.00%
发文量
3
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信