多排计算机断层扫描对肺结节候选者及其周围环境进行三维分析的计算机辅助检测。

Radiation medicine Pub Date : 2008-11-01 Epub Date: 2008-11-22 DOI:10.1007/s11604-008-0272-5
Sumiaki Matsumoto, Yoshiharu Ohno, Hitoshi Yamagata, Daisuke Takenaka, Kazuro Sugimura
{"title":"多排计算机断层扫描对肺结节候选者及其周围环境进行三维分析的计算机辅助检测。","authors":"Sumiaki Matsumoto,&nbsp;Yoshiharu Ohno,&nbsp;Hitoshi Yamagata,&nbsp;Daisuke Takenaka,&nbsp;Kazuro Sugimura","doi":"10.1007/s11604-008-0272-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We have been developing a computer-aided detection (CAD) system for lung nodules on multidetector row computed tomography (MDCT). The scheme for nodule detection in this system is featured by three-dimensional analysis of nodule candidates [corrected] and their surroundings, which is designed to discriminate nodules from blood vessels. The purpose of this study was to evaluate the CAD system.</p><p><strong>Materials and methods: </strong>MDCT images from 30 patients with lung nodules were read twice, 3 weeks apart by a chest radiologist to detect noncalcified nodules of > or = 4 mm. The first reading was without CAD, and the second reading was with CAD. Based on the reference standard later determined by another chest radiologist, the sensitivity of the former chest radiologist without or with CAD was obtained; the sensitivity and false-positive rate of the system alone were also obtained.</p><p><strong>Results: </strong>The reference standard consisted of 66 nodules. The sensitivity of the chest radiologist was 77% (51/66) without CAD and 91% (60/66) with CAD, showing a significant improvement. The CAD system alone showed a sensitivity of 79% (52/66) with the false-positive rate of 4.5 per patient.</p><p><strong>Conclusion: </strong>Although preliminary, these results indicate the efficacy of the CAD system.</p>","PeriodicalId":49640,"journal":{"name":"Radiation medicine","volume":"26 9","pages":"562-9"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s11604-008-0272-5","citationCount":"22","resultStr":"{\"title\":\"Computer-aided detection of lung nodules on multidetector row computed tomography using three-dimensional analysis of nodule candidates and their surroundings.\",\"authors\":\"Sumiaki Matsumoto,&nbsp;Yoshiharu Ohno,&nbsp;Hitoshi Yamagata,&nbsp;Daisuke Takenaka,&nbsp;Kazuro Sugimura\",\"doi\":\"10.1007/s11604-008-0272-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We have been developing a computer-aided detection (CAD) system for lung nodules on multidetector row computed tomography (MDCT). The scheme for nodule detection in this system is featured by three-dimensional analysis of nodule candidates [corrected] and their surroundings, which is designed to discriminate nodules from blood vessels. The purpose of this study was to evaluate the CAD system.</p><p><strong>Materials and methods: </strong>MDCT images from 30 patients with lung nodules were read twice, 3 weeks apart by a chest radiologist to detect noncalcified nodules of > or = 4 mm. The first reading was without CAD, and the second reading was with CAD. Based on the reference standard later determined by another chest radiologist, the sensitivity of the former chest radiologist without or with CAD was obtained; the sensitivity and false-positive rate of the system alone were also obtained.</p><p><strong>Results: </strong>The reference standard consisted of 66 nodules. The sensitivity of the chest radiologist was 77% (51/66) without CAD and 91% (60/66) with CAD, showing a significant improvement. The CAD system alone showed a sensitivity of 79% (52/66) with the false-positive rate of 4.5 per patient.</p><p><strong>Conclusion: </strong>Although preliminary, these results indicate the efficacy of the CAD system.</p>\",\"PeriodicalId\":49640,\"journal\":{\"name\":\"Radiation medicine\",\"volume\":\"26 9\",\"pages\":\"562-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s11604-008-0272-5\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s11604-008-0272-5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2008/11/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s11604-008-0272-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2008/11/22 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

摘要

目的:我们一直在开发一种多排计算机断层扫描(MDCT)肺结节的计算机辅助检测(CAD)系统。该系统的结节检测方案的特点是对结节候选物[校正]及其周围环境进行三维分析,旨在将结节与血管区分开来。本研究的目的是评估CAD系统。材料和方法:对30例肺结节患者的MDCT图像进行两次读取,间隔3周,胸部放射科医生检查>或= 4mm的非钙化结节。第一次读数没有CAD,第二次读数有CAD。根据后来另一位胸科医师确定的参考标准,获得原胸科医师无CAD或有CAD的敏感度;获得了系统单独检测的灵敏度和假阳性率。结果:参照标准包括66个结节。无CAD胸科医师的敏感性为77%(51/66),有CAD胸科医师的敏感性为91%(60/66),有明显改善。单独CAD系统的灵敏度为79%(52/66),每例患者的假阳性率为4.5。结论:虽然是初步的,但这些结果表明了CAD系统的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Computer-aided detection of lung nodules on multidetector row computed tomography using three-dimensional analysis of nodule candidates and their surroundings.

Purpose: We have been developing a computer-aided detection (CAD) system for lung nodules on multidetector row computed tomography (MDCT). The scheme for nodule detection in this system is featured by three-dimensional analysis of nodule candidates [corrected] and their surroundings, which is designed to discriminate nodules from blood vessels. The purpose of this study was to evaluate the CAD system.

Materials and methods: MDCT images from 30 patients with lung nodules were read twice, 3 weeks apart by a chest radiologist to detect noncalcified nodules of > or = 4 mm. The first reading was without CAD, and the second reading was with CAD. Based on the reference standard later determined by another chest radiologist, the sensitivity of the former chest radiologist without or with CAD was obtained; the sensitivity and false-positive rate of the system alone were also obtained.

Results: The reference standard consisted of 66 nodules. The sensitivity of the chest radiologist was 77% (51/66) without CAD and 91% (60/66) with CAD, showing a significant improvement. The CAD system alone showed a sensitivity of 79% (52/66) with the false-positive rate of 4.5 per patient.

Conclusion: Although preliminary, these results indicate the efficacy of the CAD system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信