全自动酶联免疫吸附法麸质酵母菌分析仪的评价。

S Blanco, J Domínguez, O Jiménez, D Sánchez, N Galí, L Matas, V Ausina, R Galimany
{"title":"全自动酶联免疫吸附法麸质酵母菌分析仪的评价。","authors":"S Blanco, J Domínguez, O Jiménez, D Sánchez, N Galí, L Matas, V Ausina, R Galimany","doi":"10.1155/S1463924603000051","DOIUrl":null,"url":null,"abstract":"The objective was to evaluate the automatic ELISA Triturus analyser in order to assess its practicability and imprecision. The analyser was evaluated according to the guidelines of the Spanish Society of Clinical Chemistry. The evaluation was performed in two steps: evaluation of the imprecision and the inaccuracy of a semiquantitative and qualitative technique, and study of the practicability. The within-run imprecision rate ranged from 8.9 (VC) to 10.2% (VC) for the semiquantitative test, and from 11 (VC) to 17.2% (VC) for the qualitative one. The between-run imprecision rate ranged from 6 (VC) to 9.7% (VC) for the semiquantitative test, and from 8.8 (VC) to 18% (VC) for the qualitative technique. No sample-related carryover was detected in negative samples. The relative inaccuracy was correct for both techniques. Non-specific binding caused by waste products from the analysed circuits was not detected. The Triturus analyser is a reliable open analytical system with a considerable working capability, rendering this apparatus adequate for conventional laboratories with a medium-to-high work charge.","PeriodicalId":15248,"journal":{"name":"Journal of Automated Methods & Management in Chemistry","volume":"25 2","pages":"31-4"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/S1463924603000051","citationCount":"1","resultStr":"{\"title\":\"Evaluation of the automatic ELISA Triturus analyser.\",\"authors\":\"S Blanco, J Domínguez, O Jiménez, D Sánchez, N Galí, L Matas, V Ausina, R Galimany\",\"doi\":\"10.1155/S1463924603000051\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The objective was to evaluate the automatic ELISA Triturus analyser in order to assess its practicability and imprecision. The analyser was evaluated according to the guidelines of the Spanish Society of Clinical Chemistry. The evaluation was performed in two steps: evaluation of the imprecision and the inaccuracy of a semiquantitative and qualitative technique, and study of the practicability. The within-run imprecision rate ranged from 8.9 (VC) to 10.2% (VC) for the semiquantitative test, and from 11 (VC) to 17.2% (VC) for the qualitative one. The between-run imprecision rate ranged from 6 (VC) to 9.7% (VC) for the semiquantitative test, and from 8.8 (VC) to 18% (VC) for the qualitative technique. No sample-related carryover was detected in negative samples. The relative inaccuracy was correct for both techniques. Non-specific binding caused by waste products from the analysed circuits was not detected. The Triturus analyser is a reliable open analytical system with a considerable working capability, rendering this apparatus adequate for conventional laboratories with a medium-to-high work charge.\",\"PeriodicalId\":15248,\"journal\":{\"name\":\"Journal of Automated Methods & Management in Chemistry\",\"volume\":\"25 2\",\"pages\":\"31-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/S1463924603000051\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Automated Methods & Management in Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/S1463924603000051\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Automated Methods & Management in Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/S1463924603000051","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the automatic ELISA Triturus analyser.
The objective was to evaluate the automatic ELISA Triturus analyser in order to assess its practicability and imprecision. The analyser was evaluated according to the guidelines of the Spanish Society of Clinical Chemistry. The evaluation was performed in two steps: evaluation of the imprecision and the inaccuracy of a semiquantitative and qualitative technique, and study of the practicability. The within-run imprecision rate ranged from 8.9 (VC) to 10.2% (VC) for the semiquantitative test, and from 11 (VC) to 17.2% (VC) for the qualitative one. The between-run imprecision rate ranged from 6 (VC) to 9.7% (VC) for the semiquantitative test, and from 8.8 (VC) to 18% (VC) for the qualitative technique. No sample-related carryover was detected in negative samples. The relative inaccuracy was correct for both techniques. Non-specific binding caused by waste products from the analysed circuits was not detected. The Triturus analyser is a reliable open analytical system with a considerable working capability, rendering this apparatus adequate for conventional laboratories with a medium-to-high work charge.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信